Autocall SmartSync Operation Audible Visible Notification with Multi-Tone Horn and Synchronized Flash, Non-Addressable
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-smartsync-operation-audible-visible-notification-with-multi-tone-horn-and-synchronized-flash-non-addressable-4392587610.pdf |
---|---|
Type | |
Size | 1.22 MB |
Downloads |
Text Preview
UL ULC CSFM Listed Multi Candela Notification Appliances Operation Audible Visible Notification with Multi Tone Horn and Synchronized Non Addressable and visible wall mount notification appliances with multi tone horn and high output xenon strobe Strobe operation is compatible with Americans with Disbilities Act requirements See important installation information in Table 5 Rugged high impact flame retardant thermoplastic housings are in red or white with clear lens over a two wire Autocall SmartSync circuit to provide Horn tones controlled separately from strobes on the same two wire with On until silenced and On until reset operation on the two wire pair Strobe appliances on the same circuit operating at a synchronized flash rate See Product Selection for additional SmartSync control and panel compatibility notification appliance multi tone horn Low current 24 VDC electronic multi tone horn with a selection of for each appliance Horn Bell 500 Hz Horn Slow Whoop Siren Hi Lo Use the on board DIP Switch to select the tone Slow Whoop Siren and High and Low tone selections sound their continuously synchronized to each other when receiving continuous commands SmartSync March Time pattern produces a 60 BPM output for the 500 Hz Horn and the Bell tone Output level selectable as standard or high Refer to sound output on Table 5 Listed to UL 464 and ULC S525 notification appliance strobe 24 VDC xenon strobe intensity is selectable as 15 30 75 or 110 with visible selection jumper secured behind strobe housing Regulated circuit design ensures consistent flash output and provides inrush current Listed to UL 1971 and ULC S526 mount multi tone horn and strobes features Wiring terminals are accessible from the front of the housing providing access for installation inspection and testing Covers are available separately to convert housing color Optional UL and ULC listed sound damper for locations requiring of 5 to 6 such as stairwells small rooms and highly areas Adapters are available to cover surface mounted electrical boxes and adapt to Autocall 2975 9145 boxes UL listed red wire guards are available TrueAlert multi tone horn and strobes provide wall mounted installation to standard electrical boxes Tone and output level is set for each appliance allowing notification to be tailored to specific area requirements See tone output in Table 5 Tone Selection DIP Switch selection determines the local tone A separate DIP Switch position allows selection of a standard or a output sound level selectable appropriate to the location See Table for sound output ratings designs are both impact and vandal resistant and provide a strobe intensity selection Since each model can be selected strobe intensity output and specific tone output on site model is minimized and changes encountered during construction be easily accommodated mount multi tone horn and strobe housings are a one piece including lens that mounts to a single or double gang or 4 in standard electrical box The cover can be quickly removed using tool and covers are available separately for color conversion intensity selection installation a selection plug at the back of the housing the desired strobe intensity An attached flag with black on a highly visible yellow background allows the selected intensity be seen at the side of the strobe lens application selection selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the ADA strobes Strobes When multiple strobes and their reflections can be from one location synchronized flashes reduce the probability photo sensitive reactions as well as the annoyance and possible of random flashing The multi candela strobes of these multi horn and strobes are synchronized by the controlling SmartSync NAC two wire control operation mode allows a two wire circuit to provide the ability activate both the multi tone horn and strobe on the same NAC and allow the multi tone horn to be silenced while the strobe remains The multi tone horn operates as On until silenced while the operation is On until reset 1 horn and strobes This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0527 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 3 1 2020 Operation Audible Visible Notification with Multi Tone Horn and Synchronized Flash Non Addressable control sources 4006 4007ES Hybrid 4010ES 4100ES and 4100U Fire Alarm Control Units FACUs Refer to individual product data sheets for more information 4009 IDNet NAC Extender Refer to data sheet SAC4009 0002 SmartSync Control Module SCM A4905 9938 Refer to data sheet SAC4905 0003 SmartSync compatible notification appliances include separate multi tone horns and combination multi tone horn and strobe notification Selection 1 Wall mount multi tone horn and strobe accessories Mount Adapter Skirt use to cover 1 1 2 in 38 deep surface mounted boxes Adapter Plate for mounting to Autocall 2975 9145 box typically for may be mounted vertical or horizontal Sound Damper package of 20 field installed adhesive backed output attenuator reduces output 5 to 6 dBA After Sound Damper installation measure sound level to ensure with applicable code requirements 2 SmartSync control module 3 8 in H x 5 1 4 in W x 1 5 8 in D 136 mm x mm x 41 mm depth with strobe 4 3 8 in mm 5 16 in x 5 3 4 in x 0.060 in Thick 211 mm x mm x 1.5 mm 3 4 in Diameter 44.5 mm with 0.31 in 8 mm opening SmartSync Control Module with Class B or Class A output mounts in 4 in 102 mm box refer to data sheet SAC4905 0003 for details in x 4 1 8 in x 1 1 4 in D mm x 105 mm x 32 mm 3 Replacement covers for wall mount multi tone horn or strobes cover with white FIRE lettering cover with white FIRE lettering 1 8 in H x 5 in W x 1 1 2 in D 130 mm x 127 mm x 38 mm mount red wire guard with mounting plate compatible with or surface mounted boxes 1 16 in H x 6 1 16 in W x 3 1 8 D 154 mm x 154mm x 79 mm UL listed by Space Age Electronics Inc 4 Wire guard 5 Multi tone horn and strobe specifications specifications voltage range rate and synchronized NAC loading temperature and humidity dimensions with lens 24 DC see Note 1 below Hz with up to 35 synchronized strobes maximum for each NAC F to 122 F 0 C to 50 C 10 to 93 non condensing at 100 F or 38 C blocks for 18 AWG to 12 AWG 0.82 mm to 3.31 mm two wires for each for in and out wiring 1 8 in H x 5 in W x 2 3 4 in D 130 mm x 127 mm x 70 mm horn sound output characteristics 6 Multi tone horn and strobe specifications Output Ratings for each UL 464 Chamber test at 10 ft or 3 m output dBA output dBA Output Ratings for each ULC S525 Chamber test at 3 m or 10 ft output dBA output dBA to 3700 Hz sweep at 120 Hz Hz modulated at 7 intervals Hz tone Hz to 1200 Hz Hz to 1200 Hz 1 on then repeat dBA dBA dBA dBA Hz Horn2 Whoop3 2 dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA Rev 3 1 2020 Operation Audible Visible Notification with Multi Tone Horn and Synchronized Flash Non Addressable horn sound output characteristics and Low3 tones of Hz and 800 Hz ms duration Dispersion for each ULC S525 testing 6 Multi tone horn and strobe specifications Output Ratings for each UL 464 C