Autocall TFX 500M 800M System Overview Manual

File Preview
File Preview
Click below to download for free

File Data

Name autocall-tfx-500m-800m-system-overview-manual-2781563904.pdf
Type PDF
Size 12.13 MB
Downloads

Text Preview

AUTOCALL System Overview Panel Assembly Start Up Number 19700367 3 January 1997 and understand all instructions before proceeding Autocall TFX 500M and TFX 800M fire protection systems are based and use a mix of new and traditional They are versatile flexible and completely suitable for in small to medium sized premises or systems 1 i 1 Autocall TFX 500M is field programmable to for up to 198 individual detection or annunciation points pOints can be organized into 16 conventional zones and up 240 control by event groups 2 way data circuits multiplex provide communication to and a variety of input and output devices Conventional non ad detectors may be connected individually or in small to the data circuits using the IXA 500DM or IXA 500DMA Detector Modules The TFX 500 also connects to central stations and municipal fire alarm circuits Autocall TFX 800M expands the capacity of the TFX 500 to allow up to 990 individual points 80 zones and 2 way data multiplex circuits Features and Scalable Packaging TFX to be sized to specific system requirements front with locked access to operator control panel and additional locked access to electronics standard Autocall backboxes and uses Autocall 19 by module format Door Operator Controls Fire Control Module Display Module 16 Indicator Module 80 Indicator 40 x 2 Indicator Module 16 Status control Module Status Control Module Control Modules may be used for fan control control speaker control zone disconnect switches phone control general purpose switches identification and point messages Operator passcode levels to zone assignment General or selective alarm signalling Non silenceable waterflow alarms or Evacuation signalling control by event functions grouping and manual detector sensitivity adjustment mapping defines the way the signalling appliance to Alert or Evacuation signal Test reminder disp ays a warning message and sends an alert when the routine weekly test is due addressable devices on two 2 way data multipiex communications 99 I O devices per loop addressable devices on ten 2 way data I O devices per loop common alarm annunciation circuits 1.0 Amp max per Ground Fault detection Waterflow Alarm Device functional testing Manual operation of common alarm and fault relays Features Offsite signalling with City Box Transmitter Drill Condition Indication Fault Isolation disabling and De Isolation enabling Silence Reset Test Verification PIN 940524 Reverse Polarity Module CVB 500 PIN 940525 Digital Alarm Transmitter Interface Module SRA 550 940572 Relay Module ARM 500 PIN 9760130 provides relay outputs InpuVOutput Modules XIOMs IM 16 Input PIN 976067 and OM i6 Output Module PIN inpuVoutput communication functions as driving digital display outputs and accepting digital from volt free contacts Printer Options Autocall Printer option PIN 976018 or a permanent printed record of system Communications System Up to 62 TFX 500 800 panels connect to a single TFXnet network supports up 59,400 analog addressable points 4800 zones RS 485 optic and dedicated telephone wire communications network nodes is supported TFX 500M and TFX 800M Operator Manual and Installation Guide 1 This Manual This manual is intended for use by those responsible for installing and operating the AUTOCALL fire control systems The manual provides basic instructions for installing and operating a Autocall TFX fire con panel and general instructions for installing system ancillaries If you are looking for detailed information see to Look for More Information on page iv This Manual is Organized book is organized into the following sections 1 Autocall TFX 500M 800M General System Information provides a general overview of the features and of the Autoca l TFX 500M and TFX 800M systems An overvie of general installation procedures and en installation is provided 2 Autocall TFX 500M 800M System Modules provides a description of each module board or assembly to installed in the Autocall TFX 500M or TFX 800M control panel or remote operation display panel 3 Auto call TFX 500M 800M Ancillary Device Installation provides installation instructions for each ancillary or auxiliary unit 4 Autocall TFX 500M 800M Operation Autocall TFX 500M and TFX 800M Operating Instructions gives Response to alarm supervisory and trouble conditions Remove or copy these operating instructions and them next to the appropriate control panel provides important reference information such as battery calculation worksheet system wiring information parts list and removable Operating Instructions sheets Remove the Operating Instructions Publication Num 19700371 and 19700372 sheets at the back of this book and post them within easy access of the TFX 500M or control panel s and remote operation panel s TFX 500M and TFX 800M Installation Guide iii to Look for More Information About TFX 500M 800M Ancillary Devices device is packaged with its own technical guide and installation instructions the TFX 500M and TFX 800M control panels TFX 500M and TFX 800M operator Manual Publication 850516 provides operating instructions for the and TFX 800M control panels the Autocall TFX 800M CONSYS Programming Guide Issue Publication Number 850463 Programming the TFX 500M TFX 800M Fire Control Systems via a personal computer is discussed Only authorized and trained personnel may Autocall TFX 500M and TFX 800M programming System Components and Replacement Parts Contact your local Grinnell Autocall representative or Contact Grinnell Fire Protection Company Inc 835 Sharon Drive Westlake Ohio 44145 Phone 216 871 9900 Codes and Standards National Fire Protection Association publishes codes and standards concerning ali phases of fire protection publications that directly concern automatic fire detection and control systems include but are not limited to 70 National Electrical Code NFPA 72 Installation Maintenance and Use of Protective Signalling Systems 101 Life Safety Code TFX 500M and TFX 800M Installation Guide iv of Contents TFX 500M and TFX 800M General System Information I System Overview Control Panel Assembly Start Up Procedure Network Communication System Network Operation 500M 800M Wiring Guidelines Enclosures II Fire Control Module Assembly No 976127 Operator Display Module Assembly No 976128 Module Assembly No 976129 Module TFX 500M and TFX 800M System Modules No 976136 with 1 MPIM No 976137 vlith 2l No 976138 without MPIM x 2 Indicator Module No 976130 with MPIM No 976131 without MPIM Control Module No 976134 with MPIM No 976135 without MPIM Control Module No 976132 with MPIM No 976133 without MPIM Main Processor Board TFX 500 PIN No 976037

Related Files