Autocall TrueAlarm Analog Sensors – Photoelectric and Heat; Standard Bases and Accessories

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Approved Analog Sensing Analog Sensors Photoelectric and Heat Standard Bases and Accessories analog sensing provides the following features Digital transmission of analog sensor values using IDNet two wire use with the following Autocall products 4007ES 4010ES 4100ES Series control units alarm control unit provides the folloing features Peak value logging with accurate analysis of each sensor for individual selection Sensitivity monitoring meets NFPA 72 sensitivity testing requirements individual sensor calibration check verifies sensor integrity Automatic environmental compensation multi stage alarm operation display of sensitivity directly in percent for each foot Display and print detailed sensor information in plain English language smoke sensors provide the following features Sensitivity levels from 0.2 to 3.1 See TrueAlarm sensors for more sensors have these features Three fixed temperature sensing thresholds 135 155 and 190 Rate of rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC S530 features Ceiling or wall mounting Listed to UL 268 7th Edition and ULC S529 NEMA 1 rated See TrueAlarm analog sensing product selection chart more information Louvered smoke sensor design enhances smoke capture by directing to chamber entrance areas are minimally visible when ceiling Designed for EMI compatibility Magnetic testing Different bases support a supervised or unsupervised output relay or remote LED alarm indicator base reference For isolator bases refer to data sheet AC4098 0025 For sounder bases refer to data sheet AC4098 0028 For photo heat sensors refer to data sheet AC4098 0024 single and AC4098 0033 dual address communication of analog sensing analog sensors provide an analog measurement digitally to the host control panel using Autocall addressable The control unit analyses the data determines an value and stores it Comparing the sensor s present value its average value and time determines an alarm or other condition data evaluation each sensor s average value provides a continuously reference point A software filtering process compensates for factors such as dust and dirt and component aging to an accurate reference for evaluating new activity This filtering the probability of false or nuisance alarms caused by shifts in either up or down unit selection control unit stores peak activity for each sensor to assist in specific locations The host control unit determines the alarm point for each TrueAlarm sensor selectable as more or less sensitive the individual application requires 1 A4098 9714 TrueAlarm sensor mounted in base selection can program the sensor alarm set points for timed automatic selection such as more sensitive at night less sensitive during You can program the control unit to provide multi stage operation each sensor alarm and trouble LED indication sensor base s LED pulses to indicate communications with the unit the control unit determines a sensor is in alarm is dirty or has some type of trouble the details are annunciated at the control unit and sensor s base LED will turn on steadily During a system alarm the unit will control the LEDs such that an LED indicating a trouble return to pulsing to help identify the alarmed sensors sensor bases and accessories base features mounted address selection Address remains with its programmed location Accessible from front DIP switch under sensor features Automatic identification provides default sensitivity when substituting types Integral red LED for power on pulsing or alarm or trouble steady on Locking anti tamper design mounts on standard outlet box Magnetically operated functional test This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0550 7300 7300 2269 0531 7300 2269 0538 7270 2269 0512 and 7272 2269 0537 for allowable values and or conditions concerning material presented in this document Additional may be applicable contact your local product supplier for the latest status AC4098 0019 Rev 31 10 2021 Analog Sensors Photoelectric and Heat Standard Bases and Accessories can easily interchange different TrueAlarm sensor types to meet location requirements This feature allows intentional sensor during building construction When conditions are dusty you can install heat sensors without reprogramming control unit as covering smoke sensors causes them to be disabled the control unit will indicate an incorrect sensor type the heat will operate at a default sensitivity providing heat detection for protection at that location reference bases standard sensor base sensor base with wired connections A2098 9808 remote LED alarm indicator or A4098 9822 relay relay is and requires separate 24 VDC relay bases A4098 9791 4 wire sensor base use with remote or locally mounted relay requires separate 24 VDC A4098 9780 2 wire sensor base use with remote or locally mounted relay no separate power required Supervised relay operation is programmable and can be manually from control unit Includes wired connections for remote LED alarm indicator or relay relay is unsupervised and requires separate 24 VDC base options remote or local mount supervised relay DPDT contacts for resistive suppressed loads power limited rating of 3 A at 28 VDC non power limited rating of 3 A at 120 VAC requires external 24 VDC power remote or local mount supervised relay SPDT dry contacts power limited rating of 2 A at 30 VDC resistive non limited rating of 0.5 A at 125 VAC resistive LED annunciation relay Activates when base LED is on steady indicating local alarm or trouble DPDT contacts for resistive suppressed loads power limited rating of A at 28 VDC non power limited rating of 1 2 A at 120 VAC requires 24 VDC coil power adapter plate Required for surface or semi flush mounting to 4 in square electrical and for surface mounting to 4 in octagonal box Can be used for cosmetic retrofitting to existing 6 3 8 in diameter base remote red LED alarm indicator Mounts on single gang box 2 Remote red LED alarm indicator sensor bases contain integral addressable electronics that monitor the status of the detachable photoelectric or heat Each sensor s output is digitized and transmitted to the system alarm control unit every four seconds 3 Mounting reference 1 Product mounting Model reference relay plate bases 1 A2098 9739 2 A4098 9860 A4098 9789 A4098 9792 2 AC4098 0019 Rev 31 10 2021 Analog Sensors Photoelectric and Heat Standard Bases and Accessories a slowly developing fire the temperature may not increase rapidly to operate the rate of rise feature However an alarm will be when the temperature reaches its rated fixed temperature can program TrueAlarm heat sensors as a utility device to monitor temperature extremes in the range of 32 to 155 0 to 68 feature can provide freeze warnings or alert you to HVAC system Refer to panel specifications for availability 5 A4098 9733 heat sensor with base 6 A4098 9734 high temperature heat sensor with base In most fires hazardous levels of smoke and toxic gas build up before a heat detection device would initiate an alarm In where Life Safety is a factor the use of smoke detection is highly reference locations should be determined only after careful consideration the physical layou

Related Files