Autocall TrueAlert Addressable Operation Reference and 4009 Series TrueAlert Addressable Controller
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-truealert-addressable-operation-reference-and-4009-series-truealert-addressable-controller-7241609583.pdf |
---|---|
Type | |
Size | 1.65 MB |
Downloads |
Text Preview
UL ULC CSFM Listed Addressable Notification Reference Addressable Operation Reference A4081 Series TrueAlert Addressable for installed system expansion applications Refer to TrueAlert Addressable Controller and 4100ES TPS Reference for appliance compatibility details Addressable Operation Features individually addressed notification appliance receives and control over a single wire pair providing Supervised wiring connections to each appliance that support using wiring for Class B circuits Class A circuits require in out wiring Horns sounding with selectable high or low output as Temporal 3 March Time pattern 60 or 120 bpm or Steady On controlled from visible appliances on the same two wire circuit Visible appliances operating synchronized at 1 Hz Control over power limited isolated output Signaling Line Circuits with up to 63 addressable appliances per SLC and up to appliances per control source refer to TrueAlert Addressable and 4100ES TPS Reference Specifications for detailed SLC Control sources selectable to provide individual appliance magnetic mode and appliance LED polling indicator 4100ES and 4010ES systems also provide additional control using Virtual NAC VNAC appliance groupings across SLCs across control sources B wiring advantages Less wiring distance is required since traditional end of line Class B supervision is not needed With less wiring distance required voltage drops can be reduced more appliances per wire run listed to Standard 864 TrueAlert Power Supplies TPS mounting in 4100ES control panels Three 3 A SLCs Special Application rating Addressable Controllers mounted control panel that provides Three 2.5 A SLCs Special Application rating An 8 A power supply battery charger for internal batteries up to 12.7 or up to 18 Ah in external cabinet communications formats are available Remote Unit Interface RUI communications from Autocall fire alarm control panels assigns an address point with label to each appliance for individual trouble reporting Wired control from conventional NACs connects with multiple options internal diagnostics include LED status indicators that identify channel and trouble Support for host fire alarm control panel WALKTEST system test with or RUI communications Status monitoring of battery input power and earth faults 1 Addressable Operation Reference Diagram internal modules Class A Three Channel Adapter Module IDNet Communications Repeater or Fiber Optic Receiver Repeater for Class A or Class B accessories IDNet communication fiber optic transmitters Remote TrueAlert communications isolator A4905 9929 External battery cabinet for 18 Ah batteries This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0553 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 11 01 2020 Addressable Operation Reference A4081 Series TrueAlert Addressable Controller addressable notification appliances are individually addressed and receive power supervision and control from a TrueAlert Signaling Circuit SLC For wired control systems strobe flashes and horn outputs are synchronized per controller For RUI and IDNet communications controllers on the same host control panel are synchronized Combination speaker strobe TrueAlert appliances receive audible control from audio circuit wiring addressable operation allows strobes to be wired onto the same two wire SLC circuit as horns but with separately controlled operation applications are audible notification appliances activated as on until silenced and visible notification appliances activated as on until reset Addressable Controller diagnostics can be implemented from the control panel including Silent or Active individual appliance magnet appliance LED polling indication or all appliance LEDs on Communications Control used with fire alarm control panels that support RUI communications the TrueAlert Addressable Controller can be connected to an RUI communications channel along with other RUI addressable devices The host panel can control multiple TrueAlert Addressable Controllers recommended is 20 per RUI connection Refer to Figure 3 for additional information points and custom labels are assigned to each TrueAlert appliance allowing troubles to be reported individually Additionally individual device are assigned and audible appliance coding types are selectable for high or low output 5 dBA difference and with operation as Temporal March Time pattern 60 or 120 bpm or Steady On continuous and 4010ES VNAC Details NAC VNACs Operation Groupings provide control of TrueAlert appliances similar to conventional NAC operation but VNACs include across SLCs and across SLC sources within a 4100ES or 4010ES controlled system VNACs require point allocation can be declared public use in a Network fire alarm system and can be manually controlled NOTE The terms Virtual NAC VNAC and TrueAlert Zone refer to the same and are interchangeable VNACs For programming convenience there are default VNAC groups according to device type Up to 56 custom VNACs 8 VNACs are reserved can be created per 4100ES TPS or per TrueAlert Addressable Controller connected to a 4100ES or 4010ES control panel Appliances able to be in up to three custom VNACs NOTE Appliances assigned to multiple VNACs will remain ON if any of the VNACs are ON and 4010ES Fire Alarm Control Panels can be programmed for up to 247 total custom VNACs for increased selective signaling operation Addressable Controller Product Selection FM CSFM MEA NYC 1 Standard Models voltage VAC input Addressable Controller with 3 Class B SLC channels and 8 A power supply 2 Optional Modules for on site installation channel Class A adapter Repeater output is Class A or Class B B A Class X input Appliqu for door Optic with IDNet if required either an IDNet Repeater or a Fiber Optic Receiver as if required 16 1 8 W x 5 1 2 H 410 mm x 140 mm B A Class X output 3 External Accessories select per system requirements Fiber Optic Transmitter Mounts in six gang electrical box refer to page 6 for mounting details Class B Fiber Transmitter Rev C or higher IS NOT COMPATIBLE Class B Fiber Receiver before Rev J TrueAlert Communications Isolator battery cabinet for 18 Ah batteries beige 4 Battery Selection select battery size per system requirements two batteries are required for 24 VDC operation W x 13 1 2 H x 5 3 4 D 413 mm x 343 mm x 146 mm A009 9401 has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F requires battery brackets Ah Battery 12 VDC Ah Battery 12 VDC Ah Battery 12 VDC requires external battery cabinet 2 Rev 11 01 2020 Addressable Operation Reference A4081 Series TrueAlert Addressable Controller VNAC Wiring Reference A4905 9929 Isolator Modules 4100ES Fire Alarm Control Panel The 4100ES is shown 2 wiring reference diagram 3 Rev 11 01 2020 Addressable Operation Reference A4081 Series TrueAlert Addressable Controller Communications Wiring Reference 3 communications wiring reference diagram 4009 9805 optional red appliqu kit A4603 9101 LCD Annunciator 4100ES or 4010ES Fire Alarm Control Panel 4100ES shown Communications Rules Summary Recommended limit of 20 TrueAlert Addressable Controllers 4010ES has a maximum internal and external limit of 20 card addresses Can be wired with other RUI devices LCD Annunciator shown for reference Wiring distance is up to 2500 ft 762 m continuous wiring and up to 10,000 ft 3048 m when T tapped Class B only Minimum wiring is unshielded twisted pair some applications may require shielded twisted pair consult your Autocall product supplier for Communications