Autocall TrueSite Building System Information Unit software

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Fire Alarm Systems Building System Information Unit BSIU software Version 6.02 lockout for failed attempts Operator notes Log notes associated with individual events for records and retrieval Sound files WAV can be used to create custom audible status using local onboard speakers Fahrenheit or Celsius temperatures can be displayed for screens heat sensor temperatures Software Maintenance Agreement SMA provides access to new features as well as cyber security and compatibility updates first year is included with the new system with an option to renew listings UL 864 as Fire Alarm Control Unit Annunciator UOJK S771 screens details Over 30,000 custom fields generated and edited graphic screen is available Multiple import and export formats are supported see Formats section in Graphics screens fire alarm network capabilities Multiple workstations can be nodes on the same fire alarm network to redundant operations for improved survivability Graphical diagnostic tools identify network node and loop status Set host service functions allow access to remote network node data individual TrueAlarm analog sensors Provides event printing with compatible printer view or print of status service reports TrueAlert Self Test reports and print graphic annunciation BSIU software application provides supplemental annunciation display and control for Autocall Fire Alarm Networks using a computer based graphical interface located in the same room the fire alarm control unit or other listed annunciator Response with realistic icons provide control switches specific to the being performed access levels access level is determined during log in Select functional to match the training and responsibility of the operator with additional TrueSite BSIU and fire alarm network training be qualified for access to sensitive areas For operators who are concerned with immediate facility security a lower level access provide the information necessary for proper response but will not access to key parameters that determine overall system network Listed Autocall TrueSite Building System Information Unit BSIU software provides PC based graphical command center functionality centralized annunciation historical logging report generation control of fire alarm points This application supplements other fire alarm controls 1 BSIU desktop application Autocall fire alarm network connected graphical interface control Compatible with Autocall ES Net networks Supports standard fire service annunciation icons to provide and first responders with critical fire response information Custom alarm and system messages can intuitively guide responders important information such as HAZMAT contact information and more can be quickly presented Color graphical annunciation and control of all points that are also by the fire alarm control unit or listed control annunciator in same room Floatable and dockable windows allows windows to either be fixed or floatable Pan and zoom features allow precise dynamic navigation within graphic screen for rapid and convenient selection of the area of Configurable coverage zones allow user defined areas or zones a graphics screen to indicate the area of activity without into the point of interest Auto jump allows the screen view to automatically jump to a graphic a predetermined zoom level with the active device centered on the alternately the system can be selected to auto jump to the List window Dedicated PC required The PC running the BSIU software can only the BSIU a compatible operating system and an anti virus software is not allowed Extensive historical logging Up to 500,000 events with operator information is spreadsheet and database compatible for customization Multiple password controlled operator levels with selectable feature Printer support Only connect your BSIU to a UL 864 listed printer Operating systems Compatible with Windows 10 Professional or 32 bit and 64 bit Export to XML feature allows TrueSite BSIU data to be easily exported report generation and customization Test mode allows unobtrusive testing of selective devices without interruptions at the BSIU Password security supports 8 to 16 alphanumeric passwords with to Product Selection tables for specific product listing details AC4190 0030 Rev 1 11 2021 Building System Information Unit BSIU software Version 6.02 network status views built in diagnostics are available to provide graphical views of network topology and network status Missing communications links due to breaks or shorts as well as inactive network nodes are indicated clearly to guide in returning the system to normal Information screens are to provide detail about each specific network node Network level functions such as timekeeper node and monitor node are indicated as well identification of the node being used for the diagnostic point service access BSIU operator interface provides service level access to network information that is not normally public Network private point information be accessed using the Set Host feature and logging into the database of the network and node of interest With this operation individual point can be accessed and controlled as required by qualified service personnel with proper password access Net software compatibility Net product compatibility with the BSIU software requires the following software versions 1 ES Net software requirements Programmer Programmer control unit control unit control unit Net NIC Application Net NIC EOS BSIU operation 2 ES Net firmware requirements software version or above or above firmware version or above or above or above 2 TrueSite BSIU sample alarm lists screen fire alarm network status changes occur the screen displays the type and location of the alarm or other activity and the appropriate header appear In the historical log screen above in Figure 2 Fire Priority 2 Supervisory and Trouble buttons are shown with an active Trouble screens 2 is representative of historical log screen detail Screen choices can be configured per system preference However when using multiple monitors multiple windows can be visible simultaneously for operator convenience 2 AC4190 0030 Rev 1 11 2021 Building System Information Unit BSIU software Version 6.02 of operation touchscreen monitors the operator touches the screen area in alarm or uses the mouse control to access a more detailed view of the alarmed or device With the proper password access the operator has the ability to acknowledge alarm and trouble conditions activate signal silence and system reset directly from the BSIU screens activity timeout activity timeout allows an unattended monitor to revert to the login screen when the configured time period expires user preferences user preferences appear when the user logs in Options include Font Size default or large Toolbar Size small or large Interface Theme Office 2003 or System Floating Window Options select whether to show Menu bar or show Tool bar log and list details 2 above shows historical log details The display format is similar to the display for active list items such as the alarm list Displayed information be sorted on screen by each category shown such as number time date point name and more List information can be reviewed on the screen at a local or remote system printer or can be written to an electronic file for compatibility with spreadsheet and database programs response alarm and trouble messages can be added and field edited to provide operator response assistance Point specific information such as material storage and lists of people to notify can be automatically or selectively displayed screens and floor plan details screens can provide easily recognizable site plan and floor plan information You can customize the level of det

Related Files