Autocall VESDA-E VES Aspirating Smoke Detectors with IDNet Communications

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Detection Products VESDA E VES Aspirating Smoke Detectors with IDNet Communications devices communicate on VESDAnet a bi directional network that provides continued redundant operation single point wiring failures VESDAnet enables centralized control maintenance and monitoring CSFM Listed Autocall VESDA E VES IDNet series of smoke detectors are similar the VESDA E VEP aspirating smoke detectors but include a valve in the inlet manifold and software to control the airflow the four sectors or pipes Using this configuration you can divide single zone into four separate sectors for example distinguishing separate aisles within a data room With the VES the user can the source of smoke by identifying the first sector to reach the level The detector then continues to sample from all sectors to fire growth and report separate alarm levels for each sector In the VES delivers a range of revolutionary features that provide value it works VES draws air from all sectors in use If the smoke level reaches the Scan Threshold the VES quickly scans each sector to identify sector is carrying smoke The first sector to reach the Alert level designated as the First Alarm Sector FAS and is signalled to the user two or more sectors reach the Alert level the sector with the highest concentration is designated as the FAS When the Fast Scan and identifies the FAS the VES continues to monitor all four to track fire growth and maintain full protection of the area VES aspirating smoke detector with on board IDNet communications Compatible with Autocall 4007ES 4010ES and 4100ES fire alarm units FACU Adds IDNet communications to the VESDA E VES aspirating smoke Communicates status information and receives commands from the FACU detection technology is the revolutionary detection chamber that forms the core of VESDA E VES providing higher stability and increased longevity It better detection and fewer nuisance alarms with direct imaging the sampled particles using a CMOS imager combined with multiple commissioning and operation VES aspirator provides a total pipe length of 1,706 ft 520 m operation is possible with AutoConfig which initiates normalization Xtralis ASPIRE and VSC software applications fully the VES for easy pipe network design system commissioning maintenance You can initiate the AutoLearn Smoke and Flow from VSC host FACU operations include the following Initiate detector reset Request standby mode Request disable mode Airflow normalization Silence detector host FACU information received includes the following Four alarm states alert pre alarm action pre alarm fire 1 fire 2 Urgent fault status minor fault status and standby status Analog values for smoke obscuration percentage and detector fault 1 Autocall VESDA E VES IDNet detector with addressable four pipe A4098 VES A00 P 2 Autocall VESDA E VES IDNet detector with 3.5 display addressable four pipe A4098 VES A10 P Autocall VESDA E VES IDNet series of aspirating smoke detectors a range of features that provide user value including the Sector addressability for up to four sectors Adaptive scan threshold Flair detection technology for reliable early warning in a wide range of with minimal nuisance alarms Multi stage filtration and optical protection with clean air barriers for detection performance Four configurable alarm levels for each sector and a wide sensitivity for optimum protection for the widest range of applications An intuitive LCD display providing instant status information for response Flow fault thresholds for each port accommodating varying airflow A smart onboard filter tracks dust count and remaining filter life for maintenance An extensive log of up to 20,000 events for analysis and system AutoLearn smoke and flow for reliable and rapid commissioning Ethernet for connectivity with Xtralis software for configuration monitoring and maintenance Secondary monitoring and maintenance through Wi Fi USB for PC configuration and firmware upgrade using a memory stick Two pre configured GPIs one monitored for flexible remote control Field replaceable sub assemblies for faster service and maximum These products have been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7259 0026 0508 for values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest status AC4098 0058 Rev 2 03 2022 VESDA E VES Aspirating Smoke Detectors with IDNet Communications reference UL FDA FCC CSFM A4098 VES 3.5 in display and sector status reference VES display home page has a bar graph to indicate the smoke level and adaptive scan threshold Fault icons indicate various fault conditions the adaptive scan threshold is exceeded the VES display automatically transitions to the sector status page to indicate the smoke level and level for each sector If you configure alarms as latched alarm indications for each sector are retained until you apply a reset The VES display returns to the home page by user control 3 VESDA E A4098 VES A10 P 3.5 in display 1 LED symbol reference level and adaptive scan threshold 2 Home page symbol reference 2 1 OK fault fault fault fault 2 AC4098 0058 Rev 2 03 2022 VESDA E VES Aspirating Smoke Detectors with IDNet Communications 2 Home page symbol reference fault chamber fault fault module fault element alarm level 4 VESDA E VES sector status display 3 Sector status page display reference smoke level bar graph including alarm threshold indicators sector name 3 AC4098 0058 Rev 2 03 2022 VESDA E VES Aspirating Smoke Detectors with IDNet Communications voltage current current consumption at 24 setting quiescent in alarm W x H x D Active Add conditions coverage airflow for pipe length linear length branched lengths depending number of pipes in of holes design tool 4 VESDA E 4098 VES specifications VDC to 30 VDC 24 V nominal A 0.82 A alarm 0.89 A A A A A A A lbs 4.79 kg in x 8.9 in x 5.3 in 350 mm x 225 mm x 135 mm A 32 to 100 0 to 38 air 4 to 140 20 to 60 see note 1 5 to 95 RH non condensing sq ft 2,000 m2 l m A A lbs 4.89 kg A A A A ft 280 m see note 2 ft 520 m see note 2 pipes ft 100 m pipes ft 80 m pipes ft 70 m see note 2 External diameter 1 in or 25 mm 3 4 in IPS External diameter 1 in or 25 mm 3 4 in IPS through adaptor pre configured relays non latching states rated 2 A at 30 VDC resistive to the FACU Direct connection to the IDNet loop through recommended wiring rating access termination connection from card terminal block range range setting range 1.02 in 26 mm cable entries terminal blocks 24 AWG to 14 AWG 0.2 mm2 to 2.1 mm2 AWG to 14 AWG 0.75 mm2 to 2.5 mm2 obs ft to 10 obs ft 0.000 obs m to 32 obs m obs ft to 6.25 obs ft

Related Files