Autocall VESDA-E VEU Aspirating Smoke Detectors with IDNet Communications
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-vesda-e-veu-aspirating-smoke-detectors-with-idnet-communications-7134269805.pdf |
---|---|
Type | |
Size | 1.17 MB |
Downloads |
Text Preview
Datasheet Detection Products VESDA E VEU Aspirating Smoke Detectors with IDNet Communications reference UL FDA FCC CSFM CSFM Listed Autocall VESDA E VEU IDNet series aspirating smoke detectors the premium detector of the VESDA E range With an ultra wide range 15 times greater than VESDA VLP and provision for sampling holes VEU detectors provide increased coverage of least 40 in high airflow applications Longer linear pipe runs and branched pipe network configurations cater to applications higher ceilings providing an increased coverage of up to 80 can conveniently mount VEU detectors for ease of service and In addition the VEU delivers a range of revolutionary that provide user value VEU aspirating smoke detector with onboard IDNet communications Compatible with Autocall 4007ES 4010ES and 4100ES fire alarm units FACU Adds IDNet communications to the VESDA E VEU aspirating smoke Communicates status information and receives commands from the FACU detection technology is the revolutionary detection chamber that forms the core of VESDA E VEU providing higher stability and increased longevity It better detection and fewer nuisance alarms with direct imaging the sampled particles using a CMOS imager combined with multiple commissioning and operation VEU features an IP40 rated enclosure The aspirator provides a pipe length of 2,001 ft 610 m Out of the box operation is possible AutoConfig which initiates airflow normalization Xtralis ASPIRE and software applications fully support the VEU for easy pipe network system commissioning and maintenance You can initiate the smoke and flow from the VSC host FACU operations include the following Initiate detector reset Request standby mode Request disable mode Airflow normalization Silence detector host FACU information received includes the following Four alarm states alert pre alarm action pre alarm fire 1 fire 2 Urgent fault status minor fault status and standby status Analog values for smoke obscuration percentage and detector fault devices communicate on VESDAnet a bi directional network that provides continued redundant operation during single point wiring failures VESDAnet enables centralized control maintenance and monitoring and Wi Fi connectivity and Wi Fi connectivity are standard features of VESDA E You can add the detector to a corporate network so that Wi enabled tablet devices and PCs installed with Xtralis monitoring and software can connect to the detector through the network 1 Autocall VESDA E VEU IDNet detector 3.5 in display four pipe A4098 VEU A10 2 Autocall VESDA E VEU IDNet with LEDs four pipe A4098 VEU A00 Autocall VESDA E VEU IDNet series of aspirating smoke detectors a range of features that provide unsurpassed detection flexibility field programmability connectivity and reduced cost of ownership These features include the following Flair detection technology for reliable early warning in a wide range of with minimal nuisance alarms Multi stage filtration and optical protection with clean air barriers for detection performance Four alarm levels and an ultra wide sensitivity range for optimum for the widest range of applications An intuitive LCD icon display providing instant status information for response Flow fault thresholds for each port accommodating varying airflow A smart onboard filter tracks dust count and remaining filter life for maintenance An extensive log of up to 20,000 events for analysis and system AutoLearn smoke and flow for reliable and rapid commissioning Ethernet for connectivity with Xtralis software for configuration monitoring and maintenance Industry first aspirating detector secondary monitoring and through Wi Fi USB port for PC configuration and firmware upgrade using a memory Two pre configured GPIs one monitored for flexible remote control Field replaceable sub assemblies for faster service and maximum These products have been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7259 0026 0508 for values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest status AC4098 0057 Rev 2 03 2022 VESDA E VEU Aspirating Smoke Detectors with IDNet Communications A4098 VEU A10 3.5 in display reference 3 VESDA E A4098 VEU A10 3.5 in display 1 LED symbol reference and alarm threshold levels 2 Home page symbol reference 2 1 OK fault fault fault fault fault chamber fault fault module fault 2 AC4098 0057 Rev 2 03 2022 VESDA E VEU Aspirating Smoke Detectors with IDNet Communications A A A A A A lb 5.39 kg pipes ft 150 m pipes ft 130 m pipes ft 95 m voltage current current consumption at 24 setting quiescent in alarm W x H x D Active Add Active Add conditions 3 VESDA E A4098 VEU specifications VDC to 30 VDC 24 V nominal A 0.84 A alarm 0.88 A A A A A A A lb 5.39 kg in x 8.9 in x 5.3 in 350 mm x 225 mm x 135 mm A A 32 to 100 0 to 38 air 4 to 140 20 to 60 see note 1 5 to 95 RH non condensing l m area coverage 69,965 sq ft 6,500 m2 see note 2 airflow for each lengths depending number of pipes in use 525 ft 160 m pipe lengths of holes design tool pipe pipe length with branches 2,001 ft 610 m Auto Pipe Clean External diameter 1 in or 25 mm 3 4 in IPS External diameter 1 in or 25 mm 3 4 in IPS through adaptor pre configured relays non latching states rated 2 A at 30 VDC resistive to the FACU Direct connection to the IDNet loop through recommended wiring rating access termination connection from card terminal block range range setting range 1.02 in 26 mm cable entries terminal blocks 24 AWG to 14 AWG 0.2 mm2 to 2.1 mm2 AWG to 14 AWG 0.75 mm2 to 2.5 mm2 obs ft to 10 obs ft 0.0000 obs m to 32 obs m obs ft to 6.25 obs ft 0.001 obs m to 20 obs m 0.0003 obs ft to 0.625 obs ft 0.001 obs m to 2.0 obs m 0.0003 obs ft to 0.625 obs ft 0.001 obs m to 2.0 obs m 0.0003 obs ft to 0.625 obs ft 0.001 obs m to 2.0 obs m 0.0003 obs ft to 6.25 obs ft 0.001 obs m to 20.0 obs m log up to 20,000 events level user actions alarms and faults with time and date stamp detector learns alarm thresholds and flow fault thresholds by monitoring the environment features The sampled air temperature reaches detector ambient temperature upon entry into the detector Refer to Xtralis design guides and application for sampled air pre conditioning System design and regulatory requirements may restrict the monitoring area to a lesser amount 3 AC4098 0057 Rev 2 03 2022 review for to installed VESDA E VEU Aspirating Smoke Detectors with IDNet Communications or revision 4 IDNet communications compatibility reference addressable