Autocall Visible Notification Appliances, Wall Mount Multi-Candela Strobes, Model Series 49VO

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet ES Addressable Notification Appliances Notification Appliances Wall Mount Multi Candela Strobes Model Series 49VO ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA ULC Approved FM addressed and controlled multi candela TrueAlert ES visible only notification appliances provide Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control panel or jumper selected 15 30 75 110 135 or 185 cd Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes to operate with lower current even battery backup Wiring supervision to each appliance allowing T tapped connections Class B circuits to simplify wiring Class A circuits require in out Self Test Mode allows an on board sensor to detect the strobe output then report its status to the control panel TrueAlert Device Reports at the control panel detailing appliance point custom label type and candela setting Magnet Test diagnostics to assist checkout and testing of appliances wiring and Electrical test point access without removing cover Compatibility with ADA requirements refer to Installation Reference Compatibility with legacy TrueAlert addressable systems for upgrade replacement see TrueAlert ES Strobe LEGACY Compatibility Listed to UL Standard 1971 and ULC Standard S526 Indicator and Magnet Test feature Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses the to indicate appliance address and can be set to also briefly flash strobe design features include Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters with clear lens available with ALERT FEU FEU FIRE or blank lettering Separate covers are available to change appliance type on site or for covers can be easily removed without disturbing the housing and avoiding trouble conditions A separate mounting plate allows wiring to be completed before is mounted use with single gang double gang or 4 inch box flush or surface mount In out wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover surface mounted boxes and to adapt to Autocall 2975 9145 boxes Optional red wire guards see Product Selection ES addressable strobes ES addressable strobes are individually addressed visible appliances that receive power supervision and control from the Autocall fire alarm control panel providing IDNAC Line Circuits SLCs See IDNAC SLC Controller Compatibility Application Reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code Additional listings may be applicable contact your local Autocall product supplier for the latest status 1 ES Addressable Strobes are Available Red with White Lettering and White with Red Lettering ES Operation Advantage ES addressable appliances on IDNAC SLCs provide visible and audible notification using a single two wire circuit also confirms connection to the individual notification appliance circuit This operation increases circuit supervision integrity providing supervision that extends beyond the appliance wiring current allows efficient IDNAC SLC operation With SLCs a constant 29 VDC source voltage is maintained even battery standby allowing strobes to operate at higher voltage lower current and ensuring a consistent current draw and voltage margin under both primary power and secondary battery standby include wiring distances up to 2 to 3 times farther than with notification or support for more appliances per IDNAC SLC use of smaller gauge wiring or combinations of these benefits all installation and maintenance savings with high assurance that that operate during normal system testing will operate during case alarm conditions Installation and Testing Time With separate controls on same two wire SLC installation time and expense for both retrofit new construction can be significantly reduced When Class B wiring used wiring can be T tapped allowing more savings in distance conduit size and utilization and overall installation efficiency Use Self Test and Magnet Test features improves installation efficiency device reports conveniently identify information about each appliance Rev 7 03 2021 Notification Appliances Wall Mount Multi Candela Strobes Model Series 49VO ES Diagnostics Features When IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test appliance operation can be confirmed without leaving the control panel Additionally each appliance LED can be selected to pulse when it a supervision poll during normal operation Details Selecting Self Test Mode from the control panel allows on board sensors depending on the device type to detect its own strobe horn output and then report their status to the control panel Operation is by selected VNAC appliance groups and is either automatic all simultaneously activated or individually activated by applying a magnet Refer to control panel data sheet for more Self Test information see SLC Controller Compatibility Reference Appliance Magnet Test In this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently the appliance address Appliance Magnet Test In this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash to proper operation Instrument Two TSIT The 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert appliances to its ability to test IDCs NACs and IDNet communications before connection to the control panel Please contact your local Autocall for additional information Addressable Wiring Isolator Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning See data sheet AC4905 0001 Reference 2 Reference 2 Rev 7 03 2021 Notification Appliances Wall Mount Multi Candela Strobes Model Series 49VO Plate and Surface Mount Installation Reference 2975 9145 box is shown mounted to the A4905 9931 Adapter Plates Also shown is the optional surface mount adapter skirt available in red or white A4905 9940 3 Plate and Surface Mount Installation Reference 3 Rev 7 03 2021 Notification Appliances Wall Mount Multi Candela Strobes Model Series 49VO Selection 1 TrueAlert ES Wall Mount Addressable Strobes Color cover and mounting plate separately Color ES addressable VO strobe appliances include cover and matching mounting plate except as noted Dimensions with Cover 5 H x 5 W 2 D 130 mm x 127 mm x 67 mm 2 Separate Mounting Plate Plate is required when ordering model A49VO APPLW BA 3 Separate Covers Required when ordering model 49VO APPLW BA logo only Red White Red Adapter Plate for mounting to Autocall 2975 9145 Box typically retrofit mount vertical or horizontal Mounting Box requires A4905 9931 Adapter Plate Mount Adapter Skirt 4 Mounting Adapters and Wire Guard H x 5 W x 1 D 136 mm x 133 mm x 41 mm depth with strobe 4 111 mm 5 x 5 x 0.060 Thick 211 mm x 146 mm x 1.5 mm x 5 x 2 D 200 mm x 130 mm x 70 mm 4 Rev 7 03 2021 Notification Appliances Wall Mount Multi Candela Strobes Model Series 49VO SLC Controller Compatibility Reference Sheet Controllers with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply ES Strobe Specifications

Related Files