Autocall Visual Only Notification Appliances, Weatherproof Ceiling Mount Strobe, Model Series A49VO

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC Listed ES Addressable Notification Appliances Only Notification Appliances Weatherproof Ceiling Mount Strobe Model Series Mount Addressable Visible VO Notification Appliances individually powered addressed and controlled from an Autocall alarm control panel IDNAC signaling line circuit SLC VO notification use a multi candela strobe with synchronized 1 Hz flash rate selectable candela rating LED and Xenon tube strobes devices are on the same IDNAC channel Order the appliance and separately to simplify the ordering and installation process addressed visible only VO notification appliances Multi candela LED strobe available in 110 cd 135 cd and 185 cd range models Small compact design and low current draw due to energy efficient tube strobes with LED indicators Advanced addressable notification controlled by IDNAC SLCs IDNAC SLCs provide regulated 29 VDC allowing strobes to operate lower current Remove the cover to access the electrical test point Program the strobe intensity from the control panel or the device Wiring supervision to each appliance allows T tap connections for Class circuits to simplify wiring Class A circuits require in out wiring Self Test Mode allows on board sensors to detect the strobe output report the status to the control panel TrueAlert Device Reports at the control panel detail appliance point ID label type and candela setting Magnet test diagnostics assist checkout and testing of the appliances wiring Compatibility with ADA requirements Strobe operation is listed to UL Standard 1971 and ULC Standard Synchronized strobe operation on IDNAC channel indicator and Magnet Test feature Indicator LED indicates magnet test acknowledgment three digit address and candela rating Indicator LED can be configured to blink every polling cycle to indicate supervision When the controller is in diagnostic mode the magnet test pulses the LED to indicate the appliance address and can also be set to flash the strobe LEDs design features Rugged high impact flame retardant thermoplastic housing available a variety of colors and lettering Separate covers are available for replacement or to change the Various covers and lettering options available red with white letters or type onsite with red letters Covers can be easily removed without disturbing the connected avoiding trouble conditions In out wiring terminals for 18 AWG to 12 AWG Optional wire guards 1 ES Addressable Strobe application reference selection of visible notification is dependent on occupancy and local codes addressable wiring isolator model A4905 9929 model A4905 9929 is available for remote mounting on addressable circuits to isolate short circuited wiring from wiring Refer to data sheet AC4905 0001 for additional Additional listings may be applicable contact your local Autocall product supplier for the latest status Rev 1 7 2019 Only Notification Appliances Weatherproof Ceiling Mount Strobe Model Series A49VO ES diagnostics features can be selected to pulse each appliance LED when it receives a supervision poll When the controller is selected for diagnostic mode the magnet test feature provides a response at the individual appliance being tested details Self Test Mode from the control panel allows on board sensors depending on the device type to detect its own strobe and or horn output then report their status to the control panel Operation is by selected VNAC appliance groups and is either automatic all briefly simultaneously or individually activated by applying a magnet Refer to control panel data sheet for more Self Test information appliance Magnet Test appliance LED pulses sequentially to conveniently indicate the appliance address when a magnet is applied appliance Magnet Test this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash to indicate correct operation Instrument Two TSIT second generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs and IDNet communications before connection to the control panel Contact your local Autocall representative for additional information SLC operation advantage addressable visible appliances on IDNAC SLCs Addressable visible appliances on IDNAC SLCs provide visible notification using one two wire circuit that also confirms connection to the notification appliance electronic circuit This operation increases circuit supervision integrity by providing supervision that extends beyond appliance wiring connections current usage on IDNAC SLCs constant 29 VDC source voltage is maintained even during battery standby This allows appliances to operate at higher voltage with lower current ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby Efficiencies include the Wiring distances up to three times farther than with conventional notification Support for more appliances for each IDNAC SLC Use of smaller gauge wiring installation and testing time separate controls on the same two wire SLC installation time and expense for both retrofit and new construction can be significantly reduced Class B wiring is used wiring can be T tapped allowing more savings in distance wire conduit size and utilization and overall installation Use of the magnet test feature improves installation efficiency TrueAlert device reports conveniently identify information about each appliance 2 Rev 1 7 2019 selection color Only Notification Appliances Weatherproof Ceiling Mount Strobe Model Series A49VO 1 Ceiling Mount Addressable Visual Only V O Appliances appliance only Select a cover back box separately Instructions 2 Surface WP back boxes back box in red back box in white 3 V O Covers Required when ordering APPLC models instructions logo only logo only 4 Wire Guards ceiling mount red wire guard ceiling mount wire guard back box SKU numbers ending in are assembled in the USA SLC controller compatibility reference controllers with EPS or EPS Power Supply IDNAC Repeater Flex 35 4100ES Flex 50 and 4100ES Flex Amplifiers constant supervision and signal cards 5 Compatibility reference output sheet IDNAC SLC SLC output voltage reference VDC VDC 6 VDC drop 3 Rev 1 7 2019 Only Notification Appliances Weatherproof Ceiling Mount Strobe Model Series A49VO mount VO specifications 6 Environmental specifications application 23 VDC 30 VDC to 151 40 to 66 DC control strobe voltage range temperature rating CD W135 CD W185 CD temperature rating for and uncontrolled wet Public Mode 110 CD temperature rating humidity range The appliance covers and backboxes are available in red and white Do not paint or otherwise alter the factory finishes in way to 120 40 to 49 non condensing at 140 60 for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 to 120 0 to 49 7 Maximum RMS operating current Only AO mA mA mA

Related Files