Autocall Wall and Ceiling Mount Addressable Speaker and Speaker Visible Notification Appliances
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-wall-and-ceiling-mount-addressable-speaker-and-speaker-visible-notification-appliances-8265470391.pdf |
---|---|
Type | |
Size | 898.11 KB |
Downloads |
Text Preview
UL ULC Approved Addressable Notification Appliances and Ceiling Mount Addressable Speaker and Speaker Visible Notification Appliances speakers and speaker visible appliances are individually addressed and individually controlled with power supervision and audio a compatible Autocall fire alarm control panel A combination of an IDNAC Signaling Line Circuit SLC and a compatible audio speaker circuit are for these appliances 1 and Wall Mount Addressable Speaker Only and Speaker Visible Strobes Separate appliances covers back boxes and wire guards provide complete flexibility for meeting customers installation requirements TrueAlert device reports provide important appliance information details including point ID custom label type and candela setting Rugged high impact flame retardant thermoplastic housings Covers can be easily removed without disturbing the connected housing Terminals for wiring sizes 18 AWG to 12 AWG Appliance LED can be selected to display during each polling cycle indicating appliance supervision Magnet test diagnostics to assist checkout and testing of appliances Compatible with ADA requirements Signalling Line Circuit SLC Advanced addressable notification controlled by IDNAC SLCs provides regulated 29VDC for low current operation even during battery backup Wiring supervision is electronically monitored and allows IDNAC SLC wiring to be for Class B wiring providing flexibility in reducing wiring and or distance and reducing costs for wiring installation Strobe intensity can be selected within programming from the fire alarm control panel speaker Wiring supervision is electronically monitored and allows audio speaker wiring to be for Class B wiring providing flexibility in reducing sizes and or distance and reducing costs for wiring installation Speaker taps can be selected within programming from the fire alarm control panel High quality voice and tone reproduction with taps for 1 or 2 watts at 25 or 70.7 VRMS Audio speaker circuits are wired separately from IDNAC SLCs High Fidelity models 200 to 10,000 Hz are also available Compliant with NFPA 72 520 Hz Low Frequency Signal Requirements for Sleeping Areas Listed to UL1480 and ULC S541 UL 1480 Reverberant dBA measurements 10 feet ULC S541 Anechoic dBA measurements 3 meters Additional listings may be applicable contact your local product supplier for the latest status Rev 6 6 2019 and Ceiling Mount Addressable Speaker and Speaker Visible Notification Appliances Application Reference selection of visible notification is dependent on occupancy location local codes and proper applications of the National Fire Alarm and Code NFPA 72 ANSI A117.1 the appropriate model building code BOCA ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA Addressable Wiring Isolator Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning Refer to data sheet AC4905 0001 for additional information ES Diagnostics When a controller is selected for diagnostics mode an appliance magnet test feature can be used to perform a local test of the appliance In silent the appliance LED pulses sequentially to indicate the appliances address when the magnet is applied In operational mode the strobe will flash after the address is indicated The TrueStart Instrument TSIT can be used to test wiring and appliances before connection to the control panel providing the installer with a means ensure wiring and appliance installation is complete before control panel installation This tool also tests IDCs NACs and IDNet communications Selecting Self Test mode from a compatible control panel allows sensors in the appliances depending on the device type to detect its own audio visible output reporting that status to the control panel Operation is selected by VNAC groups and can be selected as automatic all briefly activated or individually activated by applying a magnet Tests can be scheduled to occur during off times facility operation to limit during working hours and testing reports can be generated as needed Mount Appliance Product Selection 1 Wall Mount S O Appliances Refer to data sheet AC49SOW 0001 for full product selection including covers and mounting plates Series appliance only Sheet Reference fidelity S O appliance only 2 Wall Mount S V Appliances Refer to data sheet AC49SVW 0001 for full selection including covers mounting plates and multi color strobe lens S O Appliance only appliance only fidelity S V appliance only S V Appliance only Sheet Reference appliance only Sheet Reference fidelity S O appliance only High Fidelity S O Appliance Only Mount Appliance Product Selection 3 Ceiling Mount S O Appliances Refer to data sheet AC49SOC 0001 for full product selection and installation requirements 2 Rev 6 6 2019 and Ceiling Mount Addressable Speaker and Speaker Visible Notification Appliances 4 Ceiling Mount S V Appliances Refer to data sheet AC49SVC 0001 for full product selection and installation requirements Sheet Reference Canada only appliance only fidelity S V appliance only candela S V appliance only lens high fidelity high candela S V appliance only lens high fidelity high candela S V appliance only lens high fidelity high candela S V appliance only S V Appliance Only 3 Rev 6 6 2019 2019 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 6 6 2019