Autocall Wall Mount Addressable Horns, Model Series 59AO rev 3
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-wall-mount-addressable-horns-model-series-59ao-rev-3-4891365720.pdf |
---|---|
Type | |
Size | 2.40 MB |
Downloads |
Text Preview
UL ULC Approved FM addressable TrueAlert ES indoor and weatherproof horns Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allow strobes on the same Signaling Line Circuits to operate with lower current even under battery backup Wiring supervision to each appliance allows T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring Self test mode detects the horn output and then reports the status to control panel Separate control of horns from visible appliances on the same SLC with panel selection of operation as Temporal Code 3 March Time as 20 60 or 120 bpm Continuous or Temporal Code 4 High and low outputs 6 dBA difference selectable at the appliance from the controller with FACP mode selected at the appliance Magnet test diagnostics to test appliances and wiring Listed to UL Standard 464 and ULC Standard S525 Synchronized piezo operation on the same IDNAC channel Indicator and Magnet Test Indicator LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses LED to indicate appliance address and is selectable to also briefly the horn to confirm operation design features Rugged high impact flame retardant thermoplastic housing in red and Various covers options are available Red with white letters or white colors red letters Compatibility with ADA requirements Covers available in a selection of FIRE or ALERT lettering Covers can be easily removed without disturbing the connected and avoiding trouble conditions In out wiring terminals for 18 AWG to 12 AWG Indoor model mounts to single gang US electrical boxes Weatherproof model mounts to single gang weatherproof electrical ES 59 Series addressable horns individually addressed audible notification appliances that receive supervision and control signals from a Autocall fire alarm control providing IDNAC SLCs Addressable Notification Appliances Mount Addressable Horns Model Series 59AO 1 ES A59AO series Addressable are Available in Red with White and White with Red Lettering ES Operation Advantage circuit integrity ES A O addressable appliances on IDNAC SLCs provide audible using a single two wire circuit that also confirms connection the individual notification appliance electronic circuit This provides that extends beyond the appliance wiring connections current usage on IDNAC SLCs constant 29 VDC source voltage is maintained even during battery This allows strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage drop under both primary power and secondary battery standby include wiring distances up to 2 to 3 times farther than with notification support for more appliances per IDNAC SLC of smaller gauge wiring or combinations of these benefits Installation and Testing Time time and expense for retrofit or new construction is reduced with separate controls on the same two wire When Class B wiring is used wiring can be T tapped allowing savings in distance wire conduit size and utilization and installation efficiency Use of Self Test and Magnet Test features installation efficiency TrueAlert device reports conveniently information about each connected appliance Additional listings may be applicable contact your local product supplier for the latest status Rev 3 03 2021 Mount Addressable Horns Model Series 59AO ES Diagnostics allows appliance operation to be confirmed without leaving the control panel Operation is by selected VNAC appliance groups and is or individually activated by applying a magnet Test features indicate device location by pulsing the indicator LED briefly and briefly sounding the horn The indicator LED can be pulsed to indicate appliance address The horn can also be briefly sounded to indicate proper operation Instrument Two TSIT can be used to test IDNAC SLC wiring and TrueAlert ES appliances for before connecting the appliance to the panel Please contact your local Autocall representative for additional information Addressable Wiring Isolator Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning See data sheet AC4905 0001 Product Selection TrueAlert ES Addressable Electronic Horns 1 Appliance only Select cover and mounting plate separately 2 Separate Covers Required when ordering model A59AO APPLWR or A59AO APPLWW only only Model numbers ending in are assembled in the USA Product Selection TrueAlert ES Addressable Electronic Horns 3 Appliance only Select cover and mounting plate separately 4 Separate Covers Required when ordering model A59AO APPLWR O or A59AO APPLWW O 5 Surface Mount Weatherproof Boxes Required ordered separately Weatherproof model only mount weatherproof single gang mounting box includes gasket and painted versions of model 7219K23 below Order your Autocall product representative mount weatherproof single gang box order blank cover to get weatherproof gasket cover with weatherproof gasket by McMaster order from electrical supplier H x 2 W x 2 D mm x 70 mm x 51 mm Cover is not used Model numbers ending in are assembled in the USA 2 Rev 3 03 2021 SLC Controller Compatibility Reference Mount Addressable Horns Model Series 59AO 6 Compatibility Reference Sheet Output SLC Output Voltage Reference SLC VDC regulated VDC 6 VDC drop Controllers with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply ES Horn Specifications Operating Voltage Range Current Rating Requirements SLC Loading Type Setting Chamber UL 464 Test Chamber ULC 525 Test 7 Electrical Ratings VDC to 29.5 VDC Special Application mA maximum 23 VDC for connections to IDNAC SLCs unit load 0.8 mA control panel current of 127 addresses per SLC 139 unit loads dBA dBA 8 Sound Output Ratings 10 ft 3 m 23 VDC with IDNAC SLCs dBA dBA dBA dBA 9 Sound Output Dispersion per ULC S541 Anechoic Testing dBA 50 6 dBA 63 left and right from center dBA 20 above 48 below 6 dBA 65 above 60 below ref to center 10 General Specifications dBA dBA Characteristics Range Range to 3700 Hz sweep modulated at 120 Hz rate 32 to 120 F 0 to 49 C Outdoor 40 to 150 F 40 to 66 C to 93 non condensing 104 F 40 C blocks on mounting plate for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per for in out wiring A O Indoor 579 1199AC A O Weatherproof unshielded twisted pair recommended wire length allowed with T Taps for Class B wiring per SLC 10,000 ft 3048 m wire length to any appliance 4000 ft 1219 m Instructions SLC Wiring Specifications refer control panel installation instructions for information UL 464 test coded values are typical of the output measured with a Temporal or a March Time pattern and with a sound level meter reading a fast setting Under the same test conditions coded horn output peak sound level readings are typically 4 dBA higher Anechoic horn output are typically more representative of actual installed sound output 3 Rev 3 0