Autocall Wall Mount Visible and Audible Visible Notification Appliances for Emergency Communications
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-wall-mount-visible-and-audible-visible-notification-appliances-for-emergency-communications-8970425631.pdf |
---|---|
Type | |
Size | 1.47 MB |
Downloads |
Text Preview
Datasheet Addressable Notification Appliances Mount Visible Audible Visible Notification Appliances for Emergency Communications ULC Approved FM addressed and controlled multi candela TrueAlert ES Communications appliances provide Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control panel or jumper selected Standard strobe models with amber lens covers available with ALERT or blank and with red or white covers available with 15 30 110 or 135 cd output Separate lens covers are available in amber blue green and red configure strobes V O or audible visible A V appliances see Selection and TrueAlert ES Strobe with Color Lens LEGACY Reference Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes to operate with lower current even battery backup Emergency Communications appliances are controlled separately from alarm appliances but both can be on the same IDNAC SLC only type activates at a time ether fire alarm or notification not both Wiring supervision to each appliance allowing T tapped connections Class B circuits to simplify wiring Class A circuits require in out TrueAlert ES product features Self Test Mode using on board sensors TrueAlert Device Reports at the control panel Magnet Test diagnostics to assist checkout and test Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable systems for upgrade replacement see IDNAC SLC Controller Compatibility Reference Appliance LED can be selected to display polling UL listed to Standard 1638 due to non white lens verified by UL to provide light dispersion patterns of UL Standard 1971 at candela no derating necessary for amber or blue lens ULC listed to Standard S526 design features include Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters available with ALERT or blank Separate covers optional mounting adapters and red wire guards are A separate mounting plate allows wiring to be completed before is mounted use with single gang double gang or 4 inch box flush or surface mount In out wiring terminals for 18 AWG to 12 AWG clear lens TrueAlert ES appliances Refer to data sheet AC49VO 0001 for strobes Refer to data sheet AC49AV 0001 for A Vs ES addressable appliances ES addressable appliances are individually addressed and power supervision and control signals from an Autocall fire control panel providing IDNAC Signaling Line Circuits SLCs See SLC Controller Compatibility Reference Additional listings may be applicable contact your local product supplier for the latest status 1 ES Notification Appliances for Emergency are available with ALERT or Blank lettering Application Reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA ES Operation Advantage ES addressable appliances on IDNAC SLCs provide visible and audible notification using a single two wire circuit also confirms connection to the individual notification appliance circuit This operation increases circuit supervision integrity providing supervision that extends beyond the appliance wiring current allows efficient IDNAC SLC operation With SLCs a constant 29 VDC source voltage is maintained even battery standby allowing strobes to operate at higher voltage lower current and ensuring a consistent current draw and voltage margin under both primary power and secondary battery standby include wiring distances up to 2 to 3 times farther than with notification or support for more appliances per IDNAC SLC use of smaller gauge wiring or combinations of these benefits all installation and maintenance savings with high assurance that that operate during normal system testing will operate during case alarm conditions Installation and Testing Time With separate controls on same two wire SLC installation time and expense for both retrofit new construction can be significantly reduced When Class B wiring used wiring can be T tapped allowing more savings in distance conduit size and utilization and overall installation efficiency Use Self Test and Magnet Test features improves installation efficiency device reports conveniently identify information about each appliance Rev 5 03 2021 Mount Visible Audible Visible Notification Appliances for Emergency Communications ES Diagnostics Features When IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test appliance operation can be confirmed without leaving the control panel Additionally each appliance LED can be selected to pulse when it a supervision poll during normal operation Details Selecting Self Test Mode from the control panel allows on board sensors depending on the device type to detect its own strobe and horn output and then report their status to the control panel Operation is by selected VNAC appliance groups and is either automatic all briefly activated or individually activated by applying a magnet Refer to control panel data sheet for more Self Test information see IDNAC Controller Compatibility Reference Appliance Magnet Test In this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently the appliance address Appliance Magnet Test In this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash to proper operation Instrument Two TSIT The 2nd generation of the TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES to its ability to test IDCs NACs and IDNet communications before connection to the control panel Please contact your local Autocall for additional information Addressable Wiring Isolator Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring data sheet AC4905 0001 Selection 1 Configured Appliance Selection Lens covers include correct intensity selection plug Lens Covers Housing for color lens Emergency Communications Appliances Housing has setting on board for selecting color lens applications lens cover housing cover and plate separately 2 Separate Mounting Plate Required when ordering model A49VO APPLWE BA or A49AV APPLW BA BA indicates model is available either with or without the BA suffix Model numbers ending in BA APPLW and APPLWE models and separate plates are assembled in the USA 3 Housing Covers Required when ordering model A49VO APPLWE BA or A49AV APPLW BA Blank Lettering ALERT Lettering 4 Mounting Adapters and Wire Guard Mount Adapter Skirt Adapter Plate for mounting to 2975 9145 Box typically for mount vertical or horizontal Mounting Box requires Adapter Plate Blank Lettering H x 5 W x 1 D 136 mm x mm x 41 mm Total depth with 4 111 mm 5 16 x 5 x 0.060 Thick 211 mm 146 mm x 1.5 mm x 5 x 2 D 200 mm x 130 x 70 mm ALERT Lettering 2 device report reference 2 Rev 5 03 2021 Mount Visible Audible Visible Notification Appliances for Emergency Communications SLC Controller Compatibility Reference Sheet Controllers with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply ES with Color Lens Specifications 3 reference Output SLC Output Voltage Reference SLC VDC regulated VDC 6 VDC drop Operating Voltage Range Requirements