Autocall Wall Mount Weatherproof Notification Appliances Visible Only (VO) and Audible Visible (A V)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed ES Addressable Notification Appliances Mount Weatherproof Notification Appliances Visible Only VO and Audible Visible A V addressed and controlled multi candela TrueAlert ES notification appliances for extended temperature humidity range provide Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control panel or jumper selected as 30 or 75 cd Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes to operate with lower current even battery backup Wiring supervision to each appliance allowing T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring Self Test Mode allows on board sensors to detect the strobe and output and then report their status to the control panel TrueAlert Device Reports at the control panel detailing appliance ID custom label type and candela setting see sample on page 3 Magnet Test diagnostics to assist checkout and testing of appliances wiring Electrical test point access without removing cover Indicator and Magnet Test feature Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses the to indicate appliance address and can be set to also briefly flash strobe and sound the A V horn design features include Rugged high impact flame retardant thermoplastic housing with clear Standard models are red and available with FIRE or FEU lettering models are available with additional lettering of FEU FIRE and blank and in white with each lettering Mount to matching weatherproof boxes required ordered separately Separate covers are available to change application type on site or for In out wiring terminals for 18 AWG to 12 AWG Enclosure is rated NEMA 3R Convenient wiring terminal access at front of housing listings reference Strobe operation is listed to ULC S526 Horn operation is listed to ULC S525 Refer to data sheet A49WP 0001 for UL listed models 1 Weatherproof A V top and Strobe bottom view of A V on Weatherproof Mounting Boxes right A V models with horn Harmonically rich output sound for either coded or steady operation Horns sound as Temporal Code 3 March Time pattern continuous or Code 4 controlled separately from visible appliances on the two wire circuit Selectable March Time rates of 20 60 or 120 beats per minute Output is high or low 5 dBA difference selectable at the appliance or the controller with FACP mode selected at the appliance ES weatherproof addressable appliances provide visible audible visible notification for indoor and outdoor extended and extended humidity applications They are individually and receive power supervision and control signals from an fire alarm control panel providing IDNAC Signaling Line Circuits See compatibility list Table 4 application reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0521 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 5 05 2021 Mount Weatherproof Notification Appliances Visible Only VO and Audible Visible A V ES operation advantage ES addressable appliances on IDNAC SLCs provide separate visible and audible notification using a single two wire circuit that also confirms to the individual notification appliance electronic circuit This operation increases circuit supervision integrity by providing supervision that beyond the appliance wiring connections current allows efficient IDNAC SLC operation IDNAC SLCs maintain a constant 29 VDC source voltage even during battery standby allowing to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power secondary battery standby Efficiencies include wiring distances up to two to three times farther than with conventional notification or support for appliances per IDNAC SLC or use of smaller gauge wiring or combinations of these benefits all providing installation and maintenance savings high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions Installation and Testing Time With separate controls on the same two wire SLC installation time and expense for both retrofit and new can be significantly reduced When Class B wiring is used wiring can be T tapped allowing more savings in distance wire conduit size utilization and overall installation efficiency Use of Self Test and Magnet Test features improves installation efficiency TrueAlert device reports identify information about each connected appliance ES diagnostics Features When IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test appliance operation can be confirmed without leaving the control panel Additionally each appliance LED can be selected to pulse when it a supervision poll during normal operation Details Selecting Self Test Mode from the control panel allows on board sensors depending on the device type to detect its own strobe and horn output and then report their status to the control panel Operation is by selected VNAC appliance groups and is either automatic all briefly activated or individually activated by applying a magnet Refer to control panel data sheet for more Self Test information see Table 4 Appliance Magnet Test In this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently the appliance address Appliance Magnet Test In this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash and A V horn will briefly sound to indicate proper operation Instrument Two TSIT The 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert appliances to its ability to test IDCs NACs and IDNet communications before connection to the control panel Please contact your local Autocall for additional information addressable wiring isolator Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring selection 1 ULC listed TrueAlert ES addressable weatherproof notification appliances VO A V A49AV APPLW CO color lettering cover separately listed weatherproof TrueAlert ES appliance requires weatherproof below intensity ratings 30 or 75 cd 2 Separate Covers required when ordering A49AV APPLW CO VO cover models A V cover models VO cover models A V cover models 3 Wall mount weatherproof boxes required Mount Weatherproof Box required 1 2 in H x 6 1 8 in W x 1 5 8 in D mm x 156 mm x 41 mm 2 Rev 5 05 2021 Mount Weatherproof Notification Appliances Visible Only VO and Audible Visible A V device reports reference references 2 Report example A49WPBB AVVOWR white A49WPBB AVVOWW 3 Weatherproof appliance installation reference 4 Dimension and mounting height reference 3 Rev 5 05 2021 Mount Weatherproof Notification Appliances Visible Only VO and Audible Visible A V controllers sheet reference output 4 IDNAC SLC controller compatibility reference SLC SLC output VDC regulated voltage reference VDC with 6 VDC drop with EPS or EPS Power Supply

Related Files