Autocall Weatherproof Notification Appliances (non-addressable) Wall Mount Visible Only and Audible Visible
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-weatherproof-notification-appliances-non-addressable-wall-mount-visible-only-and-audible-visible-1078532964.pdf |
---|---|
Type | |
Size | 2.30 MB |
Downloads |
Text Preview
UL ULC CSFM Listed FM Multi Candela Notification Appliances Notification Appliances non addressable Wall Mount Visible Only V O and A V 24 VDC notification appliances for extended and extended humidity operation NEMA 3R rated enclosure with ratings for indoor or outdoor Rugged high impact flame retardant thermoplastic housings are in red or white with a clear lens Red housings are for indoor or outdoor applications and provide UV stable color White housings are for indoor applications with limited UV light Mounting is to matching weatherproof boxes required ordered Wiring terminals are accessible from the front of the housing providing access for installation inspection and testing listings reference UL listed to Standard 1638 for outdoor applications with strobe rated 75 candela cd WP75 UL listed to Standard 1971 for indoor applications with strobe intensity as 15 cd 60 cd or 75 cd indoor applications are compatible ADA requirements Refer to important installation information on 4 Separate models are ULC listed to Standard S526 strobes and S525 for outdoor applications with strobe intensity selectable as 5 20 cd or 30 cd Available in red only details A visible intensity selection jumper is secured behind the strobe Polarized input allows connection to compatible reverse polarity notification appliance circuit NAC Regulated circuit design ensures consistent flash output and provides inrush current A V appliances have an efficient electronic horn strobe compatibility Autocall fire alarm control units FACUs and NAC Extenders when to provide strobe synchronization or SmartSync two wire Separate strobe Synchronization Modules or SmartSync Control SCMs that convert conventional NAC inputs to a SmartSync two wire operation provides Horns controlled separately from strobes on the same two wire circuit as Temporal pattern March Time pattern at 60 BPM or on 1 A V top and strobe middle side of A V on weatherproof mounting boxes bottom multi candela TrueAlert appliances provide V O and SmartSync operation for indoor and outdoor extended temperature extended humidity applications The enclosures are impact and resistant and provide a convenient strobe intensity selection each model can be selected for intensity output on site model is minimized and changes encountered during construction easily accommodated intensity selection installation use the selection plug at the back of the housing to the strobe intensity Use the attached flag with black letters a yellow background to see the selected intensity at the side of the lens This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 226 0566 7125 2269 0527 7125 2269 0525 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest Rev 9 03 2021 Notification Appliances non addressable Wall Mount Visible Only V O and Audible Visible A V application reference selection of weatherproof notification is dependent on occupancy location local codes and correct applications of the National Fire Alarm Signaling Code NFPA 72 ANSI A117.1 the appropriate model building code BOCA ICBO or SBCCI and the application guidelines of the with Disabilities Act ADA Requirements may differ from indoor appliance applications contact your local authority having jurisdiction AHJ assist in determining requirements two wire control operation mode means that a two wire circuit can activate both the horn and strobe on the same NAC then the horn can be silenced while strobe remains flashing The horn operates as while the strobe operation is control sources two wire control is available from 4007ES Hybrid 4010ES 4100ES FACUs refer to individual product data sheets for more information 4009 IDNet NAC Extenders SmartSync Control Module SCM Model A4905 9938 Additional SmartSync compatible notification appliances include separate horns and combination horn strobe notification appliances selection V O A V 1 UL Listed TrueAlert Weatherproof Multi Candela Notification Appliances Description listed weatherproof appliance with multi candela Requires weatherproof box see Table 3 2 ULC Listed TrueAlert Weatherproof Multi Candela Notification Appliances listed weatherproof with multi strobe weatherproof see Table 3 lettering 3 Wall mount weatherproof boxes required V O A V 1638 cd setting 1971 cd 60 or 75 intensity ratings cd 20 cd or 30 cd mount weatherproof mounting boxes 1 2 in H x 6 1 8 in W x 1 5 8 in D 140 mm x 156 x 41 mm 4 Synchronization module reference refer to data sheet AC4905 0003 for additional information B A Flash Module epoxy encapsulated with in out 18 0.82 mm2 wire leads rated for 2 A NAC requires 10 mA for 3 8 in x 2 7 16 in x 13 16 in 35 mm x 62 mm x mm Control Module with Class B or Class A output mounts in 4 in 102 square box in x 4 1 8 in x 1 1 4 in D 102 mm x 105 mm x mm voltage range rate range range connections 2 1971 listed rating 1638 listed rating S526 and S525 listed rating 1971 listed rating 1638 ULC S526 and ULC S525 5 Specifications 24 VDC see note Hz up to 24 synchronized strobes maximum for each NAC to 122 0 to 50 selectable 15 cd 30 cd 75 cd to 150 35 to 66 75 cd rating to 150 40 to 66 5 cd 20 cd 30 cd rating to 93 at 100 38 to 98 at 104 40 blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires for each for in out wiring Rev 9 03 2021 Notification Appliances non addressable Wall Mount Visible Only V O and Audible Visible A V Regulated 24 VDC refers to the voltage range of 16 VDC to 33 VDC in accordance with UL 1971 and UL 1638 This voltage range is the absolute range Operation outside of this range may cause permanent damage to the strobe Please note that 16 VDC is the lowest operating voltage is allowed at the last appliance on the NAC under worst case conditions 6 Horn output Models A4906 9131 A4906 9132 UL and ULC ratings as noted sound characteristics type see note 464 reverberant chamber S525 anechoic chamber output ratings ft 3 m see note Hz to 3700 Hz sweep modulated at 120 Hz rate VDC dBA dBA VDC dBA dBA dBA dBA dBA dBA VDC dBA dBA dBA dBA Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading a fast setting Under the same test conditions coded horn output peak sound level readings are typically 4 dBA higher Anechoic horn output are typically more representative of actual installed sound output 7 Maximum RMS current ratings see note 1971 ratings 32 to 122 selection temperature Models A4906 9105 and A4906 9106 Models A4906 9131 and A4906 9132 Currents of A Vs are with horn on steady The maximum RMS current listed is the device nameplate rating Strobe designs are constant wattage the maximum RMS current rating occurs at the lowest allowable operating voltage RMS is root mean square and refers to the effective value of a current waveform cd mA mA cd mA mA cd mA mA 1638 ratings 75 cd WP75 to 150 0 66 mA mA to below 32 to 0 mA mA and option