Barber Colman MZ2A

File Preview
File Preview
Click below to download for free

File Data

Name barber-colman-mz2a-1842073695.pdf
Type PDF
Size 850.38 KB
Downloads

Text Preview

Complete user creation of custom control through block programming adapts MZII to virtually any HVAC sequence or mechanical system Models with battery backed up time clock true stand alone direct digital control optimum start stop scheduling func and battery backed up random access RAM Input output auto trending with adjustable rates continually accumulate and stamp last 48 analog values and last 10 changes of state Satellite point command capability from controllers eliminates of points half 0.5 second input to output times make MZII directly applicable static pressure fume hood and laboratory applications MICROZONE II Digital Controllers TAC NETWORK 8000 MICROZONE II MZII is a fully programmable controller that the TAC NETWORK 8000 Facility Management System family offering The has the ability to employ custom block programs and run them in a stand alone The MZII block programming language provides the system operator with 100 for creation of new and unique control strategies MICROZONE II is easily applied to a wide variety of mechanical equipment includ those that are application specific Through the Personal System Interface PSITM and Personal System Interface XPSITM control programs can be downloaded to all requiring the sequence of operation With the MZII the TAC NETWORK 8000 the best of both worlds full programmability for easy creation and modification custom control strategies and easy duplication of controller databases for mechanical containing similar or identical control strategies MZII utilizes state of the art surface mount technology which helps reduce the and cost of the product while providing powerful product features Modularity of along with the networking capabilities allow easy expandability as the needs of facility change in the future As with all other programmable TAC NETWORK 8000 the MZII utilizes non volatile EEPROM memory to store application control EEPROM memory allows an owner to modify existing control sequences or new ones through the Personal System Interface PSI asynchronous at 19,200 baud adjustable to global controller Modular jack for local connection of the Personal System Interface Terminal PSI can monitor all device parameters and has access to all program blocks and at for complete program editing and creation Provides up download capability system maintenance Device Access connected at one device has access to all network wide devices on an ASD com bus Connection of PSI will not disrupt the network communications the MZII controller and other devices on the bus NETWORK 8000 to 128 MZIIs per Global Control Module Shared network data includes all physi input output points plus capability of WINDO and EMS blocks which are program Model Chart Time Clock card only SPECIFICATIONS Functions to Table 2 TAC MICROZONE II Block Library Output Output Input Schedule PID Loops Start Stop Reset Global Group Data Schedule Sequencer Input Counter Drive Flow Detect Limit Logic Math Process Alarm Switch High Low Pulse Modulation Thermostat Status Timer Output to GCM k ohm shunt resistor kit for high speed count input ohm shunt resistor kit for 4 to 20 mA analog input k ohm shunt resistor kit for 10 k thermistor sensor non series divider converts 1 to 11 Vdc signal to 0.5 to 5 Vdc outboard gear panel H x 8 1 2 W x 4 1 4 D in 276 x 216 x 108 mm for nipple connection to MZ2 1E and MZ2 1CE panel mount H x 8 1 2 W x 4 1 8 D in 270 x 216 x 105 wall mount H x 8 1 2 W x 4 1 4 D in 276 x 216 x 108 mm Personal System Interface software see F 24317 TAC Personal System Interface software F 24317 AO DO EMS HOLI LOOP OSS RESET RGRP SCHED SEQ UI UTIL WINDO OFF Bus V Source 20 mA Input or High 10 per second Counting Input Bus Yellow Green Inputs Outputs Outputs DO Status Red Vac Power Wiring Terminal Connections and LED Indicators Fan Actuator N O Across Air Station N C N C Fan Air Temp Temp VAV pressure located distance the duct Enable All field wiring shall be twisted shielded pairs MZII Control Schematic of a Typical Fan Tracking VAV Air Handling System SERIES SPECIFICATIONS to NEMA 1 UL 916 rated Supply Input to 30.0 Vac 50 60 Hz Power Consumption VA at 50 60 Hz Compliance Tests C62.41 IEEE 587 Categories A B Discharge Test kV to case kV to field wiring LIMITS Temperature Smoke Control 25 nominal Energy Management to 140 40 to 60 and Storage Temperature to 140 40 to 60 to 95 RH non condensing 7 MHz clock speed 16 bit size KB of EPROM 2 KB of EEPROM 8 of RAM Terminals Figure 1 Backup Clock and RAM days replaceable lithium battery to 5 Vdc Backed up Time Clock sec mo at 77 25 To Digital Conversion Resolution to 20 mAdc with 250 ohm shunt resis bit bit To Analog Conversion Resolution to Output Response Time seconds maximum INPUTS Input to 140 6.67 to 60 range Barber Colman TS 5700 850 or equivalent Input to 250 40 to 121 range Barber Colman TS 8000 series or Input to 240 35 to 116 range Barber Colman TS 5600 series or Input to 240 40 to 116 range Barber Colman TS 5800 series or to 20,000 ohm resistance Input Pulse Count Rate per second 50 msec minimum On Off time per pulse to 1 per 4 min 1 input per MZII per second 0.5 sec minimum On or time per pulse to 1 per minute up 7 inputs per MZII OUTPUTS to 20 mA range programmable source 500 ohm maximum load momen short circuit protection OUTPUTS Ratings VA at 24 Vac pilot duty VA at 120 Vac pilot duty Type C SPDT isolated Indication emitting diode Reference Vdc 20 mA maximum 2006 TAC brand names trademarks and registered trademarks are property of their respective owners Information contained this document is subject to change without notice rights reserved Clifford Avenue Box 2940 Park IL 61132 2940 F 24315 6

Related Files