Barber Colman MZ2A 1
File Preview
Click below to download for free
Click below to download for free
File Data
Name | barber-colman-mz2a-1-2670349815.pdf |
---|---|
Type | |
Size | 1.00 MB |
Downloads |
Text Preview
MICROZONE II I A Series MICROZONE II MZII is a fully programmable that enhances the I A Series Facility Management family offering The MZII has the ability to employ custom programs and run them in a stand alone mode The MZII programming language provides the system operator with flexibility for creation of new and unique control strategies II is easily applied to a wide variety of mechanical including those that are application specific Through Personal System Interface PSITM and Xtended Personal Interface XPSITM control programs can be downloaded all devices requiring the sequence of operation With the MZII I A Series provides the best of both worlds full for easy creation and modification of custom strategies and easy duplication of controller databases for equipment containing similar or identical control MZII utilizes state of the art surface mount technology which reduce the size and cost of the product while providing product features Modularity of hardware along with the capabilities allow easy expandability as the needs of facility change in the future As with all other programmable Series controllers the MZII utilizes non volatile EEPROM to store application control programs EEPROM memory an owner to modify existing control sequences or create ones through the Personal System Interface PSI Complete user creation of custom control strategies through programming structure adapts MZII to virtually any HVAC sequence or mechanical system Models with battery backed up time clock provide true direct digital control with optimum start stop functions and battery backed up random access RAM Input output auto trending with adjustable sample rates accumulate and time stamp last 48 analog values last 10 digital changes of state Satellite point command capability from global controllers of unused points half 0.5 second input to output response times make directly applicable to static pressure fume hood and pressurization applications Building Systems Inc Clifford Avenue Box 2940 Park IL 61132 2940 in U S A Copyright 2004 Invensys Building Systems Inc All rights reserved Model Chart card Clock Specifications See Table 1 Conforms to NEMA 1 UL 916 rated Supply Input Power Consumption 20 VA at 50 60 Hz Approvals to 30.0 Vac 50 60 Hz File E71385 Category PAZX File LR 3728 Class B File S5381 Categories UUKL QVAX and UDTZ Compliance Tests ANSI C62.41 IEEE 587 A and B Discharge Test kV to case kV to field terminals Limits Temperature Smoke Control 77 25 nominal Energy Management 40 to 140 40 to 60 and Storage Temperature 40 to 140 40 to 5 to 95 RH non condensing 80C198 7 MHz clock speed 16 bit word size 64 KB of EPROM 2 KB of EEPROM 8 KB of RAM Terminals See Figure 1 Backup Clock and RAM 30 days replaceable lithium Backed up Time Clock Accuracy sec mo at 25 To Digital Conversion Resolution 10 bit To Analog Conversion Resolution 10 bit to Output Response Time 0.5 seconds maximum Inputs 8 Input 20 to 140 6.67 to 60 range TS 5700 850 series or equivalent Input 40 to 250 40 to 121 range TS 8000 series or equivalent Input 31 to 240 35 to 116 range TS 5600 series or equivalent Input 40 to 240 40 to 116 range TS 5800 series or equivalent 1000 to 20,000 resistance 0 to 5 Vdc 4 to 20 mAdc with 250 shunt resistor Input Dry Pulse Count Rate per second 50 msec minimum On or Off time per pulse to per 4 minutes 1 input per MZII per second 0.5 sec minimum On or Off time per pulse to 1 minute up to 7 inputs per MZII Outputs 4 0 to 20 mA range programmable source into 500 load momentary short circuit protection Outputs 8 Ratings VA at 24 Vac pilot duty VA at 120 Vac pilot duty Type Form C SPDT isolated Indication Light emitting diode Reference 5.1 Vdc 20 mA maximum Specifications Functions Refer to Table 2 MICROZONE II Block Library Output Output Input Schedule PID Loops Start Stop RESET Reset RGRP Global Group Data SCHED Schedule Sequencer Input AO DO EMS HOLI LOOP OSS SEQ UI UTIL Counter Drive Flow Detect Limit Logic Math Process Alarm Switch High Low Pulse Modulation Thermostat Status Timer WINDO Output to GCM Copyright 2004 Invensys Building Systems Inc All rights reserved RS 485 asynchronous at 19,200 baud adjustable to controller Modular jack provided for local connection of the System Interface Terminal PSI PSI can monitor all device parameters and access to all program blocks and attributes for complete editing and creation Provides up download capability for maintenance Device Access PSI connected at one device has to all network wide devices on an ASD communication Connection of PSI will not disrupt the network between the MZII controller and other devices on bus Series Up to 128 MZIIs per Global Control Module Shared data includes all physical input output points plus of WINDO and EMS blocks which are program k shunt resistor kit for high speed count shunt resistor kit for 4 to 20 mA analog k shunt resistor kit for 10 k thermistor non 850 series divider converts 1 to 11 Vdc signal to to 5 Vdc signal outboard gear panel H x 8 1 2 W x 4 1 4 D 276 mm H x mm W x 108 mm D for direct nipple to MZ2 1E and MZ2 1CE Enclosure panel mount in H x 8 1 2 in W x 4 1 8 in D mm x 216 mm x 105 mm Enclosure wall mount in H x 8 1 2 in W x 4 1 4 in D mm x 216 mm x 108 mm Personal System Interface software Xtended Personal System Interface software F 24317 F 24317 OFF Bus V Source 20 mA Input or High 10 per second Counting Input Bus Yellow Green Inputs Outputs Outputs DO Status Red Vac Power Wiring Terminal Connections and LED Indicators Copyright 2004 Invensys Building Systems Inc All rights reserved N C N C Fan Actuator N O Across Air Station Fan Air Temp Temp VAV pressure located distance the duct Enable All field wiring shall be twisted shielded pairs MZII Control Schematic of a Typical Fan Tracking VAV Air Handling System Copyright 2004 Invensys Bui