Home » Cornell Communications Duty Station HWN7606UA

File preview
Click the button below to download immediately for free
Show text preview
Station Nurse Call 5500 Nurse Call 5000 The Duty Station is a device used for visual and annunciation (by zone) of various levels of patient/staff placed in the Nurse Call System. Up to eight of these two- wall-mounted devices may be wired to the same corridor as the Patient Stations. Annunciation consists of steady flashing LEDs and tones, at an appropriate rate matching the level of the call or calls in process. User configuration of annunciation parameters allows zone assignments and rates to be pre-selected during system startup to to the unique requirements of each installation. Used for visual and audible annunciation of various levels. Each Duty Station requires a standard two-gang electrical back box, 3 deep, or Specifications: The Duty Station shall be a two- gang, wall-mounted output device, HWN7606UA, to be installed with a model HFN7611UA, two-gang, brushed stainless steel The Duty Station shall include a GREEN, YELLOW and RED LED indicator on the front and an audible sounder to annunciate various levels of calls placed in a specific zone. Also shall be output drivers to activate a 3-lamp Dome Light and external sounder, if required. Duty Station shall include a 3-position jumper array for selecting one of 8 unique polling It shall also include four output terminals for connection to four separate output A 6-position and a 3-position quick-disconnect, insulation- displacement type connector be provided to terminate field- installed power and control lines. Information: Power Requirements: 12VDC Operating Environment: 50-120 Indoor Non-condensing Physical Faceplate Dimensions: 4 x 4 (2 Gang) Mounting: Two-Gang back box with 3 minimum depth Wiring: #22 AWG Minimum
Station Nurse Call 5500 Nurse Call 5000 The Duty Station is a device used for visual and annunciation (by zone) of various levels of patient/staff placed in the Nurse Call System. Up to eight of these two- wall-mounted devices may be wired to the same corridor as the Patient Stations. Annunciation consists of steady flashing LEDs and tones, at an appropriate rate matching the level of the call or calls in process. User configuration of annunciation parameters allows zone assignments and rates to be pre-selected during system startup to to the unique requirements of each installation. Used for visual and audible annunciation of various levels. Each Duty Station requires a standard two-gang electrical back box, 3 deep, or Specifications: The Duty Station shall be a two- gang, wall-mounted output device, HWN7606UA, to be installed with a model HFN7611UA, two-gang, brushed stainless steel The Duty Station shall include a GREEN, YELLOW and RED LED indicator on the front and an audible sounder to annunciate various levels of calls placed in a specific zone. Also shall be output drivers to activate a 3-lamp Dome Light and external sounder, if required. Duty Station shall include a 3-position jumper array for selecting one of 8 unique polling It shall also include four output terminals for connection to four separate output A 6-position and a 3-position quick-disconnect, insulation- displacement type connector be provided to terminate field- installed power and control lines. Information: Power Requirements: 12VDC Operating Environment: 50-120 Indoor Non-condensing Physical Faceplate Dimensions: 4 x 4 (2 Gang) Mounting: Two-Gang back box with 3 minimum depth Wiring: #22 AWG Minimum