Home » Cornell Communications Visual Patient Station HWN7630UC

File preview
Click the button below to download immediately for free
Show text preview
Audio Nurse Call 5500 Nurse Call 5000 Patient Station The Visual Patient Station is an addressable device designed service a single or two-bed room or other patient area. The HWN7630UC an additional connector assembly, for use with satellite stations. Included the termination points and control circuits to support various devices with the same area, such as a Pull Cord Emergency Station, Staff Station, Dome Light, etc. Circuit power, ground and polling data are provided by a common, 6-conductor cable originating from the Control Unit. The Patient Station, wall-mounted near the bed, patients with an easy to use, effective method of calling for The patient presses the button on the end of the Call Cord HAN7608UA) to activate the visual and audible Annunciators with the station. Calls placed must be canceled at the Patient assuring prompt attention by the staff. Safety Call Cord disconnect (places call when removed). Separate ASSIST button for requesting assistance when pressed. Quick disconnect terminals designed for simple installation and maintenance. Specifications: The Patient Station shall be a single-gang, wall-mounted call device, model to be installed with a model HFN7601UA, single-gang, brushed stainless steel faceplate. The Station front panel shall include the following: A safety-disconnect call cord socket that accepts Model HAN7608UA Single Call Cord A tri-color CALL LED indicator, illuminated as follows: call call and ASSIST call membrane ASSIST switch membrane RESET switch Patient Station shall include a 5-position DIP switch for selecting one of 32 unique polling addresses. It also provide three input termination points for connection to auxiliary input devices, such as bath staff locator or code blue stations. It shall also include four output terminals for connection to up four separate dome light indicators. 6-position and a 9-position quick-disconnect, insulation-displacement type connector shall be provided to field-installed power and control lines. Information: Power Requirements: 12VDC Operating Environment: 50-120 Indoor Non-condensing Physical Faceplate Dimensions: 4 x 2 (1 Gang) Mounting: Single-Gang back box with 2 minimum depth Wiring: #22 AWG Minimum
Audio Nurse Call 5500 Nurse Call 5000 Patient Station The Visual Patient Station is an addressable device designed service a single or two-bed room or other patient area. The HWN7630UC an additional connector assembly, for use with satellite stations. Included the termination points and control circuits to support various devices with the same area, such as a Pull Cord Emergency Station, Staff Station, Dome Light, etc. Circuit power, ground and polling data are provided by a common, 6-conductor cable originating from the Control Unit. The Patient Station, wall-mounted near the bed, patients with an easy to use, effective method of calling for The patient presses the button on the end of the Call Cord HAN7608UA) to activate the visual and audible Annunciators with the station. Calls placed must be canceled at the Patient assuring prompt attention by the staff. Safety Call Cord disconnect (places call when removed). Separate ASSIST button for requesting assistance when pressed. Quick disconnect terminals designed for simple installation and maintenance. Specifications: The Patient Station shall be a single-gang, wall-mounted call device, model to be installed with a model HFN7601UA, single-gang, brushed stainless steel faceplate. The Station front panel shall include the following: A safety-disconnect call cord socket that accepts Model HAN7608UA Single Call Cord A tri-color CALL LED indicator, illuminated as follows: call call and ASSIST call membrane ASSIST switch membrane RESET switch Patient Station shall include a 5-position DIP switch for selecting one of 32 unique polling addresses. It also provide three input termination points for connection to auxiliary input devices, such as bath staff locator or code blue stations. It shall also include four output terminals for connection to up four separate dome light indicators. 6-position and a 9-position quick-disconnect, insulation-displacement type connector shall be provided to field-installed power and control lines. Information: Power Requirements: 12VDC Operating Environment: 50-120 Indoor Non-condensing Physical Faceplate Dimensions: 4 x 2 (1 Gang) Mounting: Single-Gang back box with 2 minimum depth Wiring: #22 AWG Minimum