DSC 2PRM 2W 4W IM EN
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-2prm-2w-4w-im-en-3271856409.pdf |
---|---|
Type | |
Size | 720.91 KB |
Downloads |
Text Preview
PRM 2W 4W Polarity Reversal Modules Instructions PRM series modules are Polarity Reversal Modules for use with the FSA series of 2 4 wire smoke detectors and smoke alarms with integral sounders These modules a connection such that when one smoke detector goes into alarm smoke detector horns will sound When the control panel is initiated into alarm it the PRM module to reverse the polarity of the power to the connected smoke Upon Power Polarity Reversal all connected smoke detectors will sound integral horn refer to Table 1 Supply Range 12 15VDC Draw Standby PRM 2W 30mA max PRM 4W 10mA Draw In Alarm PRM 2W 50mA max PRM 4W 25mA Loop Alarm Current 1.0A max Environment 0 5 93 RH non condensing 2 wire board only 2 wire enclosed 4 wire board only 4 wire enclosed of Smoke Detectors is for use with FSA 210 series 2 wire smoke detectors with integral horns This includes a Class B Style B 2 wire smoke detector zone which provides an inter for control panels that do not have a compatible 2 wire smoke detector zone of the module to the control panel is a typical 4 wire type where a reset power output and a panel fire zone input is provided The module provides a dry contact as the initiating device for the panel fire zone The module monitors Bell output of the panel to determine when a fire alarm has been initiated in the the module detects a temporal pattern or a pulsing output on the bell circuit will reverse the power to the connected smoke detectors signaling them to sound horns Alternately the module can be triggered to reverse the polarity with a dry from the control panel or from an external relay contact that is activated by an from the control panel see Fig 1 for wiring details This module can be used with FSA 210 series smoke detectors without an integral and thus provide a compatible interface to control panels that do not have a 2 wire smoke detector zone For this application the Polarity Reversal function not be used is for use with the FSA 410 series 4 wire smoke detectors with integral horns module requires resettable power from the control panel The dry contact s in the detectors are wired directly to the fire zone in the control panel module monitors the Bell output of the panel to determine when a fire alarm has initiated in the panel When the module detects a temporal pattern or a pulsing on the bell circuit it will reverse the power to the connected smoke detectors them to sound their horns Alternately the module can be triggered to re the polarity with a dry contact from the control panel or from an external relay that is activated by an output from the control panel 4 wire smoke detectors supervision RM 2 module must be installed beyond the last detector to monitor power to detectors If power fails the RM 2 will open the detection loop and initiate a condition in the control panel for that zone see Fig 2 for wiring details The PRM 4W module is also used with the FSA 410 D series of smoke alarms smoke alarms are only ULC Listed for use in Canada see Fig 3 for wiring details module to control panel and smoke detectors Table 1 and Figure 1 2 or 3 PRM can be mounted directly in the control panel using the three mounting nylon provided PRM xC modules are equipped with a plastic enclosure for exter mounting The plastic enclosure can also be mounted on top of a 2 electrical box metal conduit connections To test the system activate trigger to verify operation 1 PRM 2W 2 Wire Smoke Detectors 12 15VDC 1A max a Listed power supply protective or a control unit power output Power shall be regulated Power Limited GND T1 P P C NO EOLR EOLR RL Y1 RLY2 EOLR Power Limited Supervised operating voltage 16.40 VDC Identifier PR200 Smoke Detector to Table 1 for all names Ohm DSC model EOLR 3 Panel Alarm Note 1 Used connections must be in 20ft max and in the same room Note 2 panel Zone B Style B Input Options N O Contact Closure If a short circuit is detected at the trigger inputs the module will reverse the polarity on the smoke detector loop Bell Circuit Follower If a pulsating voltage or temporal pattern is detected at the trigger input T2 the module will reverse the polarity on the smoke detector loop 1 The drawing above shows a Bell Output with a switched negative If the Bell Output is a positive connect the positive terminal to T2 2 It is important that the zone loop on the control panel is current limited when used with 2 wire loop Ensure the maximum current of the 2 wire loop on the control panel does not exceed rating of the PRM 2W 1A 24VDC 2 PRM 4W 4 Wire Smoke Detectors GND T1 P P Power Limited Supervised 4 Wire Smoke with Integral Sounder to Table 1 for all model names Panel Class B B IDC Note 2 12 15 VDC 1A max a Listed power supply for signalling systems a control unit auxiliary output Power source be regulated resettable Power Limited Panel Alarm to Note 1 Used connections must be in conduit max and in the same room 1 The drawing above shows a Bell Output with a negative If the Bell Output is a switched positive the positive terminal to T2 2 Ensure that the zone loop on the control is current limited when used with a 2 wire loop the maximum current of the 2 wire loop on control panel does not exceed the relay contact of the FSA 410 4 wire Smoke Detector 2A 30VDC EOLR RM 2 Rela y to the RM 2 Module Installation Instructions for more details 3 PRM 4W 4 Wire Smoke Alarms 4 Mounting the PRM 2W 4W Module in the Control Unit PRM module here 3 nylon standoffs Panel Do not route any wiring circuit boards Maintain at least 25.4mm separation Limited Tie not provided prevent wires from falling onto batteries them to the enclosure or to the plastic located under the control panel fire installations come through connections 1 Current Draw