DSC 3G3070 Installation Manual - v3 5

File Preview
File Preview
Click below to download for free

File Data

Name dsc-3g3070-installation-manual-v3-5-2985164370.pdf
Type PDF
Size 1.67 MB
Downloads

Text Preview

3G3070 HSPA WIRELESS ALARM MANUAL This manual contains information on limitations regarding product and function and information on the limitations as to liability of the manu The entire manual should be carefully read OF CONTENTS 1 1 Specifications 1 1 of Parts 2 3 the 3G3070 4 the 3G3070 4 LEDS 5 Principles 6 Landline Mode 6 Transmission Monitoring PTM 6 Communications Sequence 6 6 7 the Outputs 7 Shutdown 7 Default 7 Power Radio Shutdown 8 24 Remote Programming 8 Guide 8 Wiring Diagrams 12 equipment is fixed wall mounted and shall be installed in the position specified in instructions The equipment enclosure must be fully assembled and closed with the necessary screws tabs and secured to a wall before operation Internal wiring be routed in a manner that prevents Excessive strain on wire and on terminal connections Loosening of terminal connections Damage of conductor insulation Never install this equipment during a lightning storm the end user to Not attempt to service this product Opening or removing covers may expose the user dangerous voltages or other risks Any servicing shall be referred to trained service only Use authorized accessories only with this equipment not dispose of the battery in fire or water Disposing of the battery in a fire will cause and explosion not dispose of the waste battery as unsorted municipal waste Consult your local and or laws regarding recycling with regard to this lithium battery pack Doing will help protect the environment Some of the materials that are found within the bat could become toxic if not disposed of properly and may affect the environment 3G3070 is a wireless communicator that sends alarm system information to an SurGard System I II or IV receiver through a 3G HSPA or 2G GPRS wireless network This wireless communicator can be with UL ULC Listed compatible control units as indicated in the manufacturer installation instruc The 3G3070 is designed to work with the Contact ID communication format as described in SIA DC Standard Before completing the field installation of the alarm monitoring system please ensure com with the supervising central station is successful by sending several events and getting confir that they have been received Compatible with 4 digit or 10 digit Contact ID communication format as described in SIA DC 05 Example of suitable compatible alarm panels DSC Models PC1864 PC1832 PC1616 Simulates landline Switches automatically to the 3G HSPA or 2G GPRS network in the event of landline trouble line down Wireless Signal Indicator Four programmable outputs Contains one 12V 1.2 Ah battery Case Tamper Output Landline overvoltage protection Tri band UMTS HSPA Quad Band GSM EDGE Radio Four programmable inputs 3G HSPA 2G GPRS Internet communication with Sur Gard System I II III IV Panel transmission monitoring for up to four phone numbers Specifications input voltage to the 3G3070 can be drawn from the UL ULC Listed control panel or provided by an UL ULC Listed power supply rated for the application external power limited source The power supply must be Class 2 Power Limited For residential applications a suitable power adap is model DSC ADP1310 NAU for USA and model DSC ADP1310 NA for Canada Supply Ratings Input Voltage for long term operation with internal battery 13.8VDC required without internal battery 13.8VDC recommended When the input voltage drops below 13.5VDC the internal battery supplied with the 3G3070 not be charged In order to maintain a charged level for the internal battery the power supply have a minimum voltage of 13.5VDC to ensure a sufficient battery charge in all conditions of use Consumption with internal battery 120mA without internal battery 500mA Plus any current drawn from the 3G3070 AUX terminal Voltage Range 9 14VDC sealed rechargeable type rated 12V 1.2Ah or 12V 7Ah for 24hr standby time charging voltage 13.5VDC charging current 50mA Battery must be replaced every 3 5 years frequency 850 1900MHz gain 2.0dBi Specifications temperature 0 32 93 RH Maximum non condensing Specifications metal enclosure painted 138mm x 224mm x 55mm 5.4 x 8.8 x 2.2 without battery 900g 3.2oz Event Buffer communications 256 Events not viewable Telco Loop specifications TIP RING Voltage 35VDC Current 25mA Resistance 600 Ohms construction enclosure for 3G3070RF 165mm x 257mm x 76mm 6.3 x 10.1 x 3 alternate construction enclosure without battery 1300g 2.8lbs of Parts Figure 1 Parts ON wrap O3 O4 OC AS 13 20 DC IN L1 L2 L3 L4 12V For UL ULC installa connections between alarm control panel out output relay con and 3G3070 inputs Z1 Z4 shall be in a mechanical protec conduit within 20ft 6m one another and in the room

Related Files