DSC 3G4010 - V4 0 - Installation Guide - Eng - R001

File Preview
File Preview
Click below to download for free

File Data

Name dsc-3g4010-v4-0-installation-guide-eng-r001-7034526918.pdf
Type PDF
Size 808.49 KB
Downloads

Text Preview

3G4010 HSPA Cellular Alarm Guide V4.0 installation manual visit www dsc com This manual contains informationon limitations regarding product use andfunction and inform as toliability of themanufacturer Theentiremanual shouldbecarefully read equipment is fixed wall mounted and shall be installed in the position specified in these instructions The equipment must be fully assembled and closed with all the necessary screws tabs and secured to a wall before operation wiring must be routed in a manner that prevents Excessive strain on wire and on terminal connections Loosening of terminal connections Damage of conductor insulation Never install this equipment during a lightning storm the end user to Not attempt to service this product Opening or removing covers may expose the user to dangerous voltages or other risks servicing shall be referred to trained service persons only Use authorized accessories only with this equipment not dispose of the battery in fire or water Disposing of the battery in a fire will cause rupture and explosion not dispose of the waste battery as unsorted municipal waste Consult your local regulations and or laws regarding recyc with regard to this lead acid battery Doing so will help protect the environment Some of the materials that are found within battery could become toxic if not disposed of properly and may affect the environment TO USERS INSTALLERS AUTHORITIES HAVING JURISDICTION AND OTHER INVOLVED PARTIES product incorporates field programmable software In order for the product to comply with the requirements in the Stand for Control Units and Accessories for Fire Alarm Systems UL 864 certain programming features or options must be limited the specific values or not used at all as indicated below Feature or Option in UL 864 Y N Remote Control Settings minutes 60 minutes signals permitted in UL 864 minutes see note below related signals only This product has been tested in accordance with UL 864 9th edition According to this edition of the standard the super window for reporting single technology communicator trouble shall be set to five minutes However the product can be in accordance with the requirements of NFPA72 2013 edition which allows for a 60 minute supervision window 3G4010 is a cellular communicator that sends alarm system information to a Sur Gard System I IP II III IV or 5 receiver a 3G HSPA or 2G GPRS cellular network This cellular communicator can be used with UL ULC Listed compatible units as indicated in the manufacturer installation instructions The 3G4010 is designed to work with the Contact ID communication format as described in the SIA DC 05 standard the SIA DC 03 standard for 300 baud Before completing the field installation of the alarm monitoring system please communication with the supervising central station is successful by sending several events and getting confirmation that have been received Dual band UMTS HSPA Quad Band GSM EDGE Radio Advanced Carrier Selection Bi color Wireless Signal Strength Indicator Compatible with 4 digit or 10 digit Contact ID communication format as described in SIA DC 05 Standard and the SIA DC HSPA 2G GPRS Internet communication with Sur Gard SG System I IP II III IV 5 standard for 300 baud Example of suitable compatible alarm panels Models PC1864 PC1832 PC1616 PC4020 Panel Transmission Monitoring for up to four phone numbers Simulates landline Switches automatically to the 3G HSPA or 2G GPRS network in the event of landline trouble e g line down Four Programmable NO NC SEOL Inputs 1.2Ah battery optional not included Case Tamper Output overvoltage protection Four Programmable Outputs DLS support for status firmware updates and remote debug enable Remote Firmware Upgrade Remote Diagnostics Panel Format Detection use separately listed control panel or power supply or 13.8Vdc use DSC or ADP1320 NAx power adapter SMS Command and Control Phone number call direction Easy enrollment with C24 Communications via web or mobile interface Specifications input voltage to the 3G4010 can be drawn from the UL ULC Listed control panel or provided by an external UL ULC Listed supply rated for the application external power limited source The power supply must be Class 2 Power Limited For residential applications a suitable power adaptor is model DSC or DSC ADP1320 NAU for USA and model DSC ADP1310 NA or DSC ADP1310 NA for Canada Supply Ratings Voltage Consumption Current standby with PSTN Current standby without connected Current no battery Plus any current drawn from the 3G4010 AUX terminal Voltage Range Battery Battery Type charging voltage charge current limit Battery must be replaced every 3 5 years When using the battery use DSC 1310 NA U or ADP 1320 NA U power adapter gain Specifications temperature Specifications without battery Telco Loop specifications TIP RING Voltage Voltage Maximum Current Resistance construction enclosure for 3G4010 without battery 14Vdc rechargeable type rated 12V 1.2Ah 24hr standby time x 257mm x 55mm 5.4 x 8.8 x 2.2 2.8lbs x 224mm x 55mm 5.4 x 8.8 x 2.2 3.2oz 32 Maximum non condensing Ohms of Parts circuits are classified for UL installations as Power Limited Class II Power Limited except for the battery leads which are not limited Do not route any wiring over circuit boards Maintain at least 1 25.4mm separation A minimum 1 4 6.4mm of must be maintained at all points between Power Limited wiring and all other non Power Limited wiring Route wires indicated above equipment 3G4010 is fixed and shall be installed by Service Persons only Service Person is defined as a person having appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in a task and of measures available to minimize the risks to that person or other persons It shall be installed and within an environment that provides the pollution degree max 2 over voltages category II in non hazardous indoor loc only This manual shall be used with the Installation Manual of the relevant alarm control panel All instructions specified that manual must be observed the 3G4010 Communications Enrolment 3G4010 requires enrolment with C24 Communications to operate For more information please visit www connect24 com C24 Communications customer service at 1 888 251 7458 US 1 888 955 5583 Canada or contact the central sta to inquire if they are a C24 Communications Master Reseller Enrollment with C24 Communications should be performed before turning on the 3G4010 unit inserting or removing the SIM card please ensure the unit is turned off 1 Initialize the 3G4010 with C24 Communications 3G4010 can be initialized with C24 Communications by www connect24 com m connect24 com complete enrolment a C24 profile installer ID PIN or web credentials and the 20 digit SIM number are required The SIM activation process with the cellular carrier typically takes between five and ten minutes to complete 2 Determine the Best Signal Location Remove the front cover by removing the four cover screws Apply power DC and or battery The 3G4010 is now in placement test mode 2a SIM card is activated red LED will be on solid the blue LED will be off and the signal strength LEDs will display the average signal strength In state the 3G4010 is registered to the cellular network the signal strength is too low bottom signal LED off or flashing the 3G4010 will move to Step 3 and scan for carriers with suf signal strength and attach to the carrier If the 3G4010 is connected to a carrier with sufficient signal strength minimum of signal strength LED on solid it will move to Step 4 2b SIM card is not activated red LED will flash the blue LED will be off and the signal strength LEDs will display the average signal strength this state the 3G4010 is unable to register to the cellular network because it is inactive The signal strength indicated is from nearby cell tower including cellular towers belonging to non roaming partners and does not neces

Related Files