DSC 432spec sheet

File Preview
File Preview
Click below to download for free

File Data

Name dsc-432spec-sheet-1765249308.pdf
Type PDF
Size 651.96 KB
Downloads

Text Preview

Power432SpecSheet 9 8 04 9 25 AM Page 2 32 Zone Hybrid Security System 32 Zone Hybrid Security System Specifications contractor shall provide a complete electrically supervised battery fire and burglary alarm system The system shall be complete with a alarm system with the capacity of up to 8 burglar or Class B fire zones which up to 32 may be wireless zones All zones shall be supervised and be of operating listed heat detectors smoke detectors alarm contacts detectors glassbreak detectors vibration detectors and other listed fire burglary alarm detection devices The system shall have 1 low current voltage and 1 high current voltage output All outputs shall be programmable to for 1 of 20 options System shall be complete with a 4 wire unshielded communications bus that allows system modules and keypads to be added on the bus up to 1,000 feet 330m per leg from the main control panel shall be able to withstand temporary shorts of up to 12V without control damage The system shall be capable of providing 550mA of 12VDC auxiliary for alarm devices alarm panel shall be capable of digital communications via regular telephone LINKS cellular LINKS long range radio and DVACS to two separate monitoring or locations with 2 account numbers and 3 telephone numbers LINKS communication shall be capable of backup or sole communications to stations and for upload download operations The system communicator be capable of communicating in all major formats including SIA and Contact Events transmitted shall be programmable to include fire alarms burglary trouble alarms supervisory conditions alarm restoral codes opening and closing arming codes partial closing codes and opening after codes The system shall be capable of paging personnel on the occurrence any of the above events selected by the owner The system shall be capable of a test code to the monitoring station s on a programmable daily or monthly frequency at a regular time of day shall be a 700mA PTC protected supervised bell siren circuit that will drive bell siren until reset or silenced Siren output shall be programmable as steady pulsed for each zone alarm panel shall be equipped with EEPROM memory to retain all program even if all AC and battery power is lost and shall have integral static lightning protection circuitry prevent false alarms and unnecessary transmissions to monitoring stations the panel shall have SIA false alarm prevention features programmable swinger by zone audible exit delay audible exit fault opening after alarm reporting bell squawk urgency on entry delay exit programmable delay by zone and transmission delay on AC failure TLM trouble low recent close code and cross zone police code system shall have stay away and stay arming capability to allow the user to on the premises while the system is armed A quick arm feature shall allow without access codes to arm the system and exit A door chime feature shall the keypad to beep when a selected door is opened or closed system shall support any combination of up to 8 dual language and LED type with backlit displays Keypads shall be surface mounted and of fully programming and operating the system Each keypad shall be to operate the entire system Dual language keypads shall be complete 32 character liquid crystal display LCD to provide plain language instructions operating instructions and display of all alarms and conditions They shall be capable of toggling between languages by a keypad key combination LED keypads shall have 8 zone indicators All shall have keypad activated emergency alarms for panic emergency fire duress 5 programmable function keys or programmable keypad functions indicators for Ready Armed and Trouble or System and shall be equipped a piezo buzzer to provide audible feedback for correct key entries pre alert trouble keypad shall have one zone input to allow a zone detector to be wired to the keypad system shall allow 39 access codes including 32 user codes 1 master code duress codes 2 supervisor codes 1 installer code and 1 maintenance code system shall be uploadable downloadable to allow programming and operation a directly connected local computer or from a remote computer over a line or LINKS cellular communications equipment Remote access shall controlled by the owner to prevent unauthorized access system shall support a 300 1200 2400 or 4800 bps serial printer connected the communications bus up to 1,000 feet 330m from the control panel The shall log all system events and transactions with time and date stamp shall be stored in the system 128 event buffer which can be from the LCD keypad or via DLS software system shall meet UL standards as required for relevant type of application Power432 brings remarkable new technology product design together in a system that is for residential commercial and institutional More than a burglar alarm the is a complete life safety and security offering the latest advances in hybrid burglary and fire protection the Power432 provides superior electronic of life and property it also supplies full range of system control options that be fully customized to meet the exact of the system owner quality complete design flexibility customized system control and the reliable security your customers can count for years to come it all adds up to the Power432 from DSC Zones Hardwired or Wireless 4 programmable panel zones expandable to 8 zones keypad zone inputs 1 zone per keypad or wireless zones PC5132 433 wireless receiver module LCD5501Z32 433 connect up to 32 wireless zones to 8 Keypads up to 8 hardwired keypads 3 hardwired keypad models available PC1555RKZ eight zone LED keypad with zone input PC5508Z eight zone LED keypad with zone input LCD5500Z alphanumeric keypad with zone input added wireless control is provided by WLS918 433 wireless panic pendant WLS919 433 wireless key Programmable Voltage Outputs PGM1 and PGM2 with 20 programmable options Communications supports all major formats including SIA and Contact ID supports Skyroute cellular communicator DVACS using PC5400DV SG in place of PC5400 printer module event initiated personal paging 3 phone numbers 3rd backs up primary number 2 account numbers Installation 4 wire communications bus KEYBUS connect keypads and modules up to 1000 330m control panel in Canada 11 02 North American 29002864 Digital Security Controls Ltd Canada ISO9001 registered company more Power432 information go to 9 8 04 9 25 AM Page 3 Main Control Panel up to 8 fully programmable zones use any combination of hardwire zones on main control panel keypad input zones 1 per keypad wireless zones using PC5132 wireless receiver all zones programmable as burglary or fire 1 zone wiring options include Normally Closed Single End of Line resistor and Double EOL resistor 1 zones cannot be programmed as fire zones if Double EOL resistor is enabled 27 programmable zone types 8 programmable zone attributes all events automatically stored with time and date stamp to buffer events can be printed on site viewed through the LCD Keypad or 128 event buffer software alarm output bell output 700mA 12VDC PTC protected 2 programmable voltage outputs PGM1 low current 50mA 12VDC PGM2 low current 50mA 12VDC 20 programmable options local PCLINK and remote upload download capability PCLINK allows direct connection of PC to alarm panel program system using DLS software view status and trouble conditions view 128 event buffer 1.5A regulated power supply auxiliary power 12VDC 550mA positive temperature coefficient PTC AUX Bell output protection electronically protected from KEYBUS faults supervision for AC power loss and low battery clock locked to AC power frequency battery required 12V 4Ah rechargeable sealed lead acid transformer required 16.5VAC 40VA Operation 39 access codes 32 user codes 1 master code 2 duress

Related Files