DSC addendum communicator-battery upgrade SCW9055-57
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-addendum-communicator-battery-upgrade-scw9055-57-0496132875.pdf |
---|---|
Type | |
Size | 1.56 MB |
Downloads |
Text Preview
ADDENDUM COMMUNICATOR UPGRADE document describes how to convert the SCW9055 57 Cellular Ready alarm panel into an SCW9055 57 G 433 868 using the communicator upgrade kit this Addendum in conjunction with the SCW9055 57 Installation Manual please observe all safety instructions specified within that manual Figure 1 Clip Retainer upgrade requires replacement of the cellular ready SCW9055 57 backplate with the commu backplate supplied in this upgrade kit The 1.5Ah battery part 17 145 supplied the original backplate can be re used or the upgraded 3.6Ah battery part 17 152 sold sep can be installed The 1.5Ah battery part 17 145 provides 4 hour battery standby time plus 4 minutes of which meets UL ULC Residential Burglary requirements 3.6Ah battery part 17 152 provides 24 hour battery standby time plus 5 minutes alarm time meets UL ULC Residential Fire requirements remove the 1.5Ah battery Disconnect AC and Telephone lines from the SCW9055 57 the front of the alarm panel and disconnect the battery wire from the connector If the is wall mounted remove the backplate from the wall the screw on the movable retaining clip and slide the clip up figure 1 the battery retainer and lift out the battery using the 1.5Ah battery in the communicator equipped backplate the battery into the compartment with the print facing up the bottom of the retaining bracket into the slot provided then position the top of the under the retaining clip Slide the retaining clip down then tighten the screw using the 3.6Ah battery in the communicator equipped backplate With the print facing up insert the bottom of the battery into the retaining clips as shown in 2 the retaining clip down toward the battery then tighten the screw complete the installation Mount the communicator equipped backplate onto the wall using the hardware from the orig panel the battery wire into the connector on the front of the alarm panel Note the front panel the cellular ready SCW9055 57 has two battery connectors one for the 1.5Ah battery and for the 3.6Ah battery These connectors are sized for the appropriate battery the ribbon cable into the cellular communicator board then into the connector on the of the alarm panel Figure 3 the front cover by snapping it into place Figure 3 Figure 2 Clips the cellular communicator by entering installer programming cid 2 8 installer code and setting programming Section 382 Option 5 to ON If the 1.5Ah battery was installed in the communicator enabled backplate enable standard capacity battery charge by entering installer programming installer code and setting programming Section 701 Option 7 to OFF Failure to ensure the standard capacity battery charge is enabled when using the 1.5Ah battery will result in reduced service life of the battery If the 3.6Ah battery was installed in the communicator enabled backplate enable high capacity battery charge by entering installer programming installer code and setting programming Section 701 Option 7 to ON to ensure high capacity battery charge is enabled when using the 3.6Ah battery will result in reduced battery standby time and failure to meet 24 hour bat standby time required for UL ULC Residential Fire requirements 2013 Tyco International Ltd and its Respective Companies All Rights Reserved Support 1 800 387 3630 Can US Intl www dsc com Printed in Canada