DSC AMB 500 IS EN NA
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-amb-500-is-en-na-0924751683.pdf |
---|---|
Type | |
Size | 703.59 KB |
Downloads |
Text Preview
AMB 500 PIR Detector INSTRUCTIONS AMB 500 is a ceiling mount detector designed to provide reliable motion detec for residential and commercial applications The AMB 500 uses a special Fresnel made for 360 detection in conjunction with a quad element PIR sensor opti for uniform detection all around its field of view Special attention is given to alarm immunity against RF static electrical transient to ensure trouble free oper for many years AMB 500 uses a 2 wire connection for power and to communicate with the con panel This simplifies wiring and reduces installation cost The AMB 500 low cur draw also maximizes the number of devices that can be attached to an loop Current rating 0.75 mA standby 3 mA test mode Operating environment 32 0 5 93 RH non condensing Radiated RF immunity 10 V m with 80 AM over range 80MHz to 1.0GHz Conducted RF immunity 10V with 80 AM over range 150kHz to 100MHz Static immunity 15 kV Transient immunity 2.4 kV 1.2 joules Maximum detection range diameter placed 8 ft 2.4 m from floor 24 ft 7.3 m placed 10 ft 3.0 m from floor 30 ft 9.2 m placed 12 ft 3.6 m from floor 40 ft 12.2 m Walk detection speed 0.5 10 s 0.15 3m s Tamper switch contact rating 0.1A 24VDC Panel Compatibllity PC4010 4020 v3 x PC5010 PC5015 PC5020 v2 x with interface module Protected by one or more of the following patents 2099971 US 5444432 RF immunity and white light not verified by UL Patterns the Detector a detector location that will provide the coverage required keeping in mind the potential problems Do not aim the detector at reflective surfaces such as mirrors or windows as this distort the coverage pattern or reflect sunlight directly onto the detector Avoid locations that are subject to direct high air flow such as near an air duct out Do not locate the detector near sources of moisture steam or oil Do not aim the detector such that it will receive direct or reflected mirror sunlight Do not limit the coverage by large obstructions within the detection area such as or filing cabinets Wiring connect the AMB 500 consult the wiring diagram below open the case remove screw and gently twist the top cover counter clockwise and it up from the bottom cover Use a small screwdriver to remove the appropriate for wiring Mount the bottom cover close the case use the locating line on the bottom cover to align the tab on the top Once the top cover is engaged twist the top cover clockwise to lock it in place screw to attach top cover to the bottom cover Since no adjustment is necessary for the circuit board it is not recommended the installer remove the circuit board from the case Enrollment serial number located on the back of the device must be enrolled into the alarm panel via Installer Programming 8 Installer Code This procedure is for the PC4010 4020 in the control panel Installation Manual and for the panels in the PC5100 Installation Manual Connect only DSC Addressable Series devices to the addressable connections Connection of ANY other type of device will impair operation devices other than Addressable Series devices which require power to oper must be powered separately Testing the detector has been set up walk test the entire area where coverage is Should the coverage be incomplete readjust or relocate the detector to full coverage NOTE Upon installation the unit should be thoroughly tested to proper operation The end user should be instructed on how to perform tests and should walk test the detector weekly the Sensitivity features Fast and Slow detection modes which are set on jumperJ1 J1 is set at the factory for the Fast detection mode In a normal operating this setting provides the best detection certain environments where rapid air movement heaters and other variables problems use Slow detection mode to stabilize the detection change the setting from Fast to Slow take the jumper off the header COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Controls Ltd could void your to use this equipment equipment generates and uses radio frequency energy and if not installed and used properly in strict accor with the manufacturer instructions may cause interference to radio and television reception It has been type and found to comply with the limits for Class B device in accordance with the specifications in Subpart of 15 of FCC Rules which are designed to provide reasonable protection against such interference in any residen installation However there is no guarantee that interference will not occur in a particular installation If this does cause interference to television or radio reception which can be determined by turning the equip off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits necessary the user should consult the dealer or an experienced radio television technician for additional sugges The user may find the following booklet prepared by the FCC helpful to Identify and Resolve Radio Interference Problems This booklet is available from the U S Government Printing Office Washing D C 20402 Stock 004 000 00345 4 WARRANTY Security Controls Ltd warrants that for a period of twelve months from the date of purchase the product be free of defects in materials and workmanship under normal use and that in fulfilment of any breach of such Digital Security Controls Ltd shall at its option repair or replace the defective equipment upon return of equipment to its repair depot This warranty applies only to defects in parts and workmanship and not to damage in shipping or handling or damage due to causes beyond the control of Digital Security Controls Ltd such lightning excessive voltage mechanical shock water damage or damage arising out of abuse alteration or application of the equipment foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warran whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Digital Security Controls Ltd neither assumes nor authorizes any other person purporting to act on its behalf modify or to change this warranty nor to assume for it any other warranty or liability concerning this product no event shall Digital Security Controls Ltd be liable for any direct indirect or consequential damages loss of profits loss of time or any other losses incurred by the buyer in connection with the purchase installa or operation or failure of this product detectors can only detect motion within the designated areas as shown in their respective installation instruc They cannot discriminate between intruders and intended occupants Motion detectors do not provide volu area protection They have multiple beams of detection and motion can only be detected in unobstructed covered by these beams They cannot detect motion which occurs behind walls ceilings floor closed doors partitions glass doors or windows Any type of tampering whether intentional or unintentional such as mask painting or spraying of any material on the lenses mirrors windows or any other part of the detection system impair its proper operation infrared motion detectors operate by sensing changes in temperature However their effectiveness can be when the ambient temperature rises near or above body temperature or if there are intentional or uninten sources of heat in or near the detection area Some of these heat sources could be heaters radiators stoves fireplaces sunlight steam vents lighting and so on Digital Security Controls Ltd recommends that the entire system be completely tested on a regular However despite frequent testing and due to but not limited to criminal tampering or electrical dis it is possible for this product to fail to perform as expected Information Changes or modifications not expressly approved by Digital Security Controls Ltd void the user authority to operate this equipment Digital Security Controls Ltd Canada cid 127