DSC AMB-600 Installation Manual (English)

File Preview
File Preview
Click below to download for free

File Data

Name dsc-amb-600-installation-manual-english-7593028164.pdf
Type PDF
Size 755.75 KB
Downloads

Text Preview

AMB 600 PIR Detector INSTRUCTIONS AMB 600 is a specialized Dual PIR motion sensor which immunity from false alarms caused by pets AMB 600 is equipped with a specially designed lens enables the detector to discriminate between humans small to mid sized pets Signal Processing temperature compensation large multi beam lens design means the human target not slip by unnoticed even on a hot summer day Immu against false alarms from RF static electrical transients white light are all features designed and integrated by AMB 600 uses a 2 wire connection for power and to with the control panel This simplifies wiring reduces installation cost The AMB 600 low current also maximizes the number of devices that can be to an addressable loop Patented Protected by one or more of the following patents Canada 2099971 5444432 RF Immunity not verified by UL Pet Immunity has not been by UL Current Rating 3.5 mA standby 6.5 mA with Test LED on Operating Environment 32 to120 0 to 49 5 to 93 RH non condensing RF immunity 10 V m 80 A M over range 80 MHz to 1.0 GHz Static immunity 15 kV Transient immunity 2.4 kV 1.2 joules Walk detection speed 0.5 to 10 0.15 m s to 3 m s Coverage angle 100 maximum Vertical adjustment 5 to 10 Mounting heights 6 to 10 2m to 3 m nominal 7.5 2.3m Dimensions 4.9 H 2.76 W 1.75 D 124.5 mm 70 mm 44.5 mm Tamper Switch Contact Rating 0.1A 30 VDC RF immunity not verified by UL Panel Compatibllity PC4010 4020 v3 x PC5010 5015 5020 v2 x with PC5100 interface module PC5020 v3.0 and higher Patterns for AMB 600 Lens the Detector a detector location that will provide the coverage required keeping in mind the following problems Do not aim the detector at reflective surfaces such as mirrors or windows as this may distort the pattern or reflect sunlight directly onto the detector Avoid locations that are subject to direct high air flow such as near an air duct outlet Do not locate the detector near sources of moisture steam or oil Do not aim the detector such that it will receive direct or reflected mirror sunlight Do not limit the coverage by large obstructions within the detection area such as plants or filing Do not aim the detector at a stairway which a pet has access to Do not place furniture or objects than 3 ft 0.9 m which a pet can climb onto e g a cat on a couch closer than 6 ft 1.8 m to detector Wiring connect the AMB 600 consult the wiring diagram below open the case use a small flat blade screwdriver and gently push in the tab at the bottom of the and pull the cover straight out at the bottom Loosen the printed circuit board screw and push board up as far as it will go Using a small screwdriver remove the appropriate knockouts for the screws Remove the desired wiring entrance knockouts located at the top or bottom of the Mount the backplate mounting screws diagonally opposite each other to prevent the case from warping Enrollment serial number located on the back of the device must be enrolled into the alarm control panel Installer Programming 8 Installer Code This procedure is outlined for the PC4010 v3 x in the control panel Installation Manual and for Power panels in the PC5100 Installation Connect only DSC Addressable Series devices to the addressable loop Connection of ANY other type of device will impair operation Any other than Addressable Series devices which require power to operate must powered separately Adjustment Range and dead zones may vary due to settings the figures listed below set the vertical adjustment to get the desired coverage Ensure that PCB retaining screw is tightened just enough to prevent board movement from Floor Adjustment 1.8 m 2.3 m 2.6 m 2.7 m 3.2 m 0.75 0.00 0.50 0.75 1.25 the circuit board down will increase the far range and bring the near beams closer to the wall Moving the circuit board UP will reduce the far range and move the near beams far out from the mounting wall Moving the circuit board UP too much will cause the far beams to above the target as a result the range may appear shorter J1 selects between harsh and normal environments For a typical environment or one con a small pet height less than 1.2 ft 0.36 m set the unit as normal J1 ON For a large pet multiple pets the jumper J1 should be removed Testing the detector has been set up walk test the entire area where coverage is desired Should the be incomplete readjust or relocate the detector to obtain full coverage NOTE Upon installation the unit should be thoroughly tested to verify operation The end user should be instructed on how to perform walk tests should walk test the detector weekly and DM W Detector Mounting Brackets the optional DM W Wall Mount and DM C Ceiling Mount brackets to solve difficult placement The DM W and DM C mount to either the wall or ceiling and allow for full vertical and hor positioning of the motion detector the detector can be tilted up or down and rotated through to obtain the best position for optimal coverage COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Controls could void your authority to this equipment equipment generates and uses radio frequency energy and if not installed and used properly in strict accordance with manufacturer instructions may cause interference to radio and television reception It has been type tested and to comply with the limits for Class B device in accordance with the specifications in Subpart of Part 15 of FCC which are designed to provide reasonable protection against such interference in any residential installation How there is no guarantee that interference will not occur in a particular installation If this equipment does cause inter to television or radio reception which can be determined by turning the equipment off and on the user is to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits necessary the user should consult the dealer or an experienced radio television technician for additional suggestions user may find the following booklet prepared by the FCC helpful to Identify and Resolve Radio Television Problems This booklet is available from the U S Government Printing Office Washington D C 20402 004 000 00345 4 WARRANTY Security Controls warrants that for a period of twelve months from the date of purchase the product shall be free defects in materials and workmanship under normal use and that in fulfilment of any breach of such warranty Digital Controls shall at its option repair or replace the defective equipment upon return of the equipment to its repair This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or han or damage due to causes beyond the control of Digital Security Controls such as lightning excessive voltage shock water damage or damage arising out of abuse alteration or improper application of the equipment foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Digital Controls neither assumes nor authorizes any other person purporting to act on its behalf to modify or to change warranty nor to assume for it any other warranty or liability concerning this product no event shall Digital Security Controls be liable for any direct indirect or consequential damages loss of anticipated loss of time or any other losses incurred by the buyer in connection with the purchase installation or operation or of this product detectors can only detect motion within the designated areas as shown in their respective installation instructions cannot discriminate between intruders and intended occupants Motion detectors do not provide volumetric area They have multiple beams of detection and motion can only be detected in unobstructed areas covered by beams They cannot detect motion which occurs behind walls ceilings floor cl

Related Files