Operation Maximum detection range diameter placed 8 ft 2.4 m from floor 24 ft 7.3 m placed 10 ft 3.0 m from floor 30 ft 9.2 m placed 12 ft 3.6 m from floor 40 ft 12.2 m Additional operating modes ON OFF Jumper J1 count fast slow Jumper J2 J2 ON is fast count RF Immunity 20V m 100Hz 1.2GHz Transients wiring terminal 2.4KV 1.2joules Operating temperature 32 122 0 50 Humidity 5 95 RH non condensing Information BV 500 Form alarm contact BV 501 Form alarm contact and tamper switch BV 502 Form alarm contact and tamper switch View at 8 ft 2.4 m height Mount Detector INSTRUCTIONS INSTRUCTIONS Bravo5 is a ceiling mount detector designed to reliable motion detection for residential commercial applications The Bravo5 uses a Fresnel lens made for 360 detection in with a quad element PIR sensor for uniform detection all around its field view Special attention is given to false alarm against RF static electrical transient to trouble free operation for many years Multi Level Signal Processing 360 coverage Quad element PIR sensor High level static and transient protection Excellent RF immunity Temperature compensation Fast Slow detection jumper LED ON OFF jumper SMD construction Super quiet operation 5 year warranty View Input Voltage 9 14.5 VDC Current nominal 18 15 mA alarm on off 12 VDC Rating Alarm Relay 0.1A 24VDC Tamper Switch 0.1A 24VDC diameter x height x 1.4 117 mm x 36 mm Patented the Detector Bravo5 is designed to be mounted on the ceiling of a indoor location for 360 coverage Ensure that the path of an intruder is perpendicular to the beam Use the coverage pattern indicated on the coverage to determine the best sensor location the mounting location and the area being protected the following potential problems Avoid the following of false alarms Surfaces not aim the detector at reflective surfaces such as or windows as this may distort the coverage pattern reflect sunlight directly onto the detector Flow locations that are subject to direct high air flow such near an air duct outlet not locate the detector near sources of steam or oil Sun not aim the detector such that it will receive direct sunlight not limit the coverage by placing large objects within the area such as plants high shelves filing cabinets etc open the case insert a small screwdriver in the tab clip Gently pry tab downward and twist the top counter clockwise and lift it up from the bottom cover a small screwdriver to remove the appropriate for wiring Mount the bottom cover using the supplied close the case use the locating line on the bottom cover align the tab on the top cover Once the top cover is twist the top cover clockwise to lock it in place Since no adjustment is necessary for the circuit it is not recommended that the installer remove the board from the case to the following diagram for wiring instructions Up application of power the LED will be on for 90 seconds to indicate that the unit is warming During this period the relay is held in its alarm state After 90 second warm up period the LED will turn off and the will respond to motion in the protected area NOTE Upon installation test the unit tested to ensure it works properly The end user be instructed on how to perform walk tests and perform a walk test of the detector weekly Test movement in the entire area where coverage is LED on the unit will turn on whenever motion is detected J1 must be on coverage is incomplete relocate the unit You can make adjustments by rotating the detector several degrees to the coverage pattern diagrams as a guide to the detector for better coverage the detector coverage is as required you may turn off alarm LED by removing the jumper from J1 the Sensitivity features Fast and Slow detection modes which are on jumper J2 Jumper J2 is set at the factory for the Fast mode In a normal operating environment this provides the best detection certain environments where rapid air movement heaters other variables present problems use Slow detection to stabilize the detection change the setting from Fast to Slow take the jumper off header Warranty Security Controls Ltd warrants that for a period of five years the date of purchase the product shall be free of defects in and workmanship under normal use and that in fulfilment any breach of such warranty Digital Security Controls Ltd shall its option repair or replace the defective equipment upon return the equipment to its repair depot This warranty applies only to in parts and workmanship and not to damage incurred in or handling or damage due to causes beyond the control of Security Controls Ltd such as lightning excessive voltage shock water damage or damage arising out of abuse or improper application of the equipment foregoing warranty shall apply only to the original buyer and is shall be in lieu of any and all other warranties whether expressed implied and of all other obligations or liabilities on the part of Security Controls Ltd Digital Security Controls Ltd neither nor authorizes any other person purporting to act on its to modify or to change this warranty nor to assume for it any warranty or liability concerning this product no event shall Digital Security Controls Ltd be liable for any direct or consequential damages loss of anticipated profits loss of or any other losses incurred by the buyer in connection with the installation or operation or failure of this product detectors can only detect motion within the designated ar as shown in their respective installation instructions They can discriminate between intruders and intended occupants Motion do not provide volumetric area protection They have beams of detection and motion can only be detected in areas covered by these beams They cannot detect which occurs behind walls ceilings floor closed doors glass glass doors or windows Any type of tampering whether or unintentional such as masking painting or spraying any material on the lenses mirrors windows or any other part of detection system will impair its proper operation infrared motion detectors operate by sensing changes in tem However their effectiveness can be reduced when the ambi temperature rises near or above body temperature or if there are or unintentional sources of heat in or near the detection Some of these heat sources could be heaters radiators stoves fireplaces sunlight steam vents lighting and so on Digital Security Controls Ltd recommends that the entire be completely tested on a regular basis However despite frequent and due to but not limited to criminal tampering or electrical it is possible for this product to fail to perform as expected Information Changes or modifications not expressly approved Digital Security Controls Ltd could void the user authority to operate equipment 1999 Digital Security Controls Ltd Canada Tech Line 1 800 387 3630 29002462 R002

Related Files