DSC BV 200 and BV 300 - Installation Instructions - EN - NA

File Preview
File Preview
Click below to download for free

File Data

Name dsc-bv-200-and-bv-300-installation-instructions-en-na-0418539267.pdf
Type PDF
Size 772.60 KB
Downloads

Text Preview

lens BV L1 UV Bravo2 40 l 40 w 12.2 cid 127 Bravo3 50 l 60 w 15.2 18.3m INSTRUCTIONS Bravo2 and Bravo3 are general purpose PIR detectors designed to reliable motion detection for residential and commercial The detectors are similar in design The Bravo3 however a larger coverage area when greater range is required design care and factory testing ensure years of trouble free The detectors provide immunity against false alarms from static electrical transient and white light signal processing temperature compensation and a large lens design means that the human target will not slip by on a hot summer day interchangeable lenses wall or corner mounting and vertical provide application versatility Your client will appreciate the size and elegant simplicity of the case design Protected by one or more of the following patents 2099971 US 5444432 voltage 9.5VDC 14.5VDC voltage ripple 3.0V PP 12VDC current 16mA in alarm 20mA rating 100mA 24VDC contact resistor in common 10 1 4W temp 0 32 temp 40 40 humidity 5 95 RH non cond humidity up to 99 RH non cond immunity 10 V m plus 80 AM from 80MHz to 1GHz immunity 8kV contact 15 kV air immunity 2.4kV 1.2 joules detection speed 0.5 10 s 0.15 3m s angle BV L1 90 minimum adjustment 5 to 10 heights 6 10.5 1.8 3.2m nominal 7.5 2.3m 4 5 1.2 1.5m pet alley only Form A alarm contact Form A alarm contact tamper switch Form C alarm contact tamper switch lens BV L2 UV Bravo2 70 l 6 w 21.3 1.8m Bravo3 80 l 10.5 w 24.4 3.2m lens BV L3 UV Bravo2 40 l 3.5 w 12.2 1.1m cid 127 Bravo3 50 l 4.4 w 15.2 1.3m Alley lens BV L4 UV Bravo2 40 l 40 w 12.2 cid 127 Bravo3 50 l 60 w 15.2 The Detector a detector location that will provide the coverage required Consider following to avoid false alarms Do not aim the detector at reflective surfaces such as mirrors or windows as may distort the coverage pattern or reflect sunlight directly onto the Avoid locations that are subject to direct high air flow such as near an air outlet Do not locate the detector near sources of moisture such as steam or oil Do not locate the detector in the path of direct or reflected mirror sunlight For premises with pets use the pet alley lens Do not limit the coverage by large obstructions in the detection area such plants or cabinets open the case use a small flat blade screwdriver and gently push in the at the bottom of the case and pull the cover straight out at the bottom the PCB screw and push the board up as far as it will go Using a screwdriver remove the appropriate knockouts for the mounting Remove the left and or right wiring entrance knockouts located at top of the backplate Mount the backplate to the wall using the appropriate screws not supplied Adjustment Range and dead zones may vary due to settings the Mounting Height Chart see below set the vertical adjustment for desired coverage The height will be indicated by the gauge located at the right hand corner of the circuit board Ensure that the PCB retaining is tightened just enough to prevent board movement the circuit board down will increase the far range and move the near farther out from the mounting wall the circuit board up will reduce the far range and bring the near beams to the mounting wall Moving the board down too much will cause the beams to above the target As a result the range may appear shorter Height Chart for Full Range by lens type BV L2 UV BV L3 UV BV L4 UV the detector has been set up create motion in the entire area where is desired Should the coverage be incomplete readjust or the detector Once coverage is as required the alarm LED may disabled by setting J1 to OFF Brackets the optional DM W wall and DM C ceiling mount to solve placement The brackets allow for and horizontal position of the detector The DM C can tilted up or down and rotated 90 to obtain the best for optimal coverage your DSC distributor for information regarding these solutions are two jumpers on the detector circuit board JUMPER J1 will enable the alarm LED If J1 is OFF the LED will not operate on alarm If is ON the LED will operate on alarm J2 selects between fast and slow operation For a typical environment unit should be set to J2 ON If the environment presents potential which cannot be avoided set J2 to J2 OFF When using the corridor lens set J2 to ON Lenses detector is supplied with the wall to wall lens BV L1 UV To change lens release the top tab and pull the lens holder out This action releases lens Insert the new lens with the GROOVES FACING INWARD The of the lens is indicated by two triangular indentations Ensure that lens is centered and then reattach the lens holder The lens holder will into place sealing the lens into position The corridor lens should not be used for corridors then 6 1.8m wide Ensure the beams are aimed directly the centre of corridor This unit is UL Listed and should be connected to a control unit or power supply providing at least 4 hours standby power Warranty Security Controls Ltd warrants that for a period of 12 months from the date of purchase product shall be free of defects in materials and workmanship under normal use and that in of any breach of such warranty Digital Security Controls Ltd shall at its option repair replace the defective equipment upon return of the equipment to its repair depot This warranty only to defects in parts and workmanship and not to damage incurred in shipping or handling damage due to causes beyond the control of Digital Security Controls Ltd such as lightning voltage mechanical shock water damage or damage arising out of abuse alteration or application of the equipment foregoing warranty shall apply only to the original purchase and is and shall be in lieu of any all other warranties whether expressed or implied and of all other obligations or liabilities on part of Digital Security Controls Ltd Digital Security Controls Ltd neither assumes responsibility authorizes any other person purporting to act on its behalf to modify or to change this warranty to assume for it any other warranty or liability concerning this product no event shall Digital Security Controls Ltd be liable for any direct indirect or consequential loss of anticipated profits loss of time or any other losses incurred by the buyer in with the purchase installation or operation or failure of this product detectors can only detect motion within the designated areas as shown in their respective instructions They cannot discriminate between intruders and intended occupants detectors do not provide volumetric area protection They have multiple beams of and motion can only be detected in unobstructed areas covered by these beams They detect motion which occurs behind walls ceilings floor closed doors glass partitions doors or windows Any type of tampering whether intentional or unintentional such as painting or spraying of any material on the lenses mirrors windows or any other part the detection system will impair its proper operation infrared motion detectors operate by sensing changes in temperature However the

Related Files