DSC BV-300 - Installation Manual - English - Bravo3 Passive Infrared Motion Detector

File Preview
File Preview
Click below to download for free

Text Preview

Series DETECTOR Multi Level Signal Processing Dual element low noise sensor Four interchangeable lenses High level static protection High level transient protection High level of White Light Immunity Excellent RF immunity Temperature compensation Fast slow detection jumper LED on off jumper Vertical adjustment SMD construction Super quiet operation Wall corner mounting Small size Blends with any decor 5 YEAR WARRANTY Bravo 3 is a general purpose PIR designed to provide motion detection for larger residential and applications design care and factory testing ensure years trouble free performance Immunity against false alarms RF static electrical transients and white light are all in features Signal Processing and large multi beam lens design means human target will not slip by unnoticed even on a hot day interchangeable lenses wall or corner mounting and adjustment provide application versatility and client will appreciate the small size and elegant of the case design Bravo 3 with its 5 year warranty is your assurance of trouble free installation PATENT PENDING LENS VIEW VIEW LENS VIEW ft m ft m ft m ft m ft m ft m ft m voltage 9.5 VDC to 14.5 VDC voltage ripple 3.0 VP P 12 VDC current 16 mA in alarm 20 mA rating alarm tamper 100 mA 24 VDC contact resistor in common 10 ohm 0.25 W temperature 0 to 50 32 to 122 temperature 40 to 60 40 to 140 humidity 5 to 95 RH non cond humidity up to 99 RH non cond immunity 50 V m over range 0.01 MHz to 1.2 GHz immunity 25 kV immunity 2.4 kV 1.2 joules light immunity 20 000 Lux at the detector detection speed 0.5 to 10 0.15 m s to 3 m s angle wall wall lens 90 minimum adjustment 5 to 10 heights 6 to 10 nominal 7.5 m to 3 m nominal 2.3 m to 5 pet alley only m to 1.5 m pet alley only lens BV L1 50 l 60 w 16 m 18 m lens BV L2 120 l 10.5 w 36.5 m 3 lens BV L3 50 l 4.4 w 16 m 1.3 Alley lens BV L4 50 l 60 w 16 m 18 m PATTERN CHART THE CENTRE OF EACH BEAM PAIR ft m ft m ft ft m h 2.5 w 1.87 d 89 mm 64 mm 48 mm VIEW with light gray lens WEIGHT oz 190 g A alarm contact A alarm contact tamper switch C alarm contact tamper switch LENS SIDE VIEW TOP VIEW ft m ft m THE DETECTOR ADJUSTMENT a detector location that will provide the coverage keeping in mind the following potential problems Surfaces not aim the detector at reflective surfaces such as or windows as this may distort the coverage or reflect sunlight directly onto the detector locations that are subject to direct high air flow such near an air duct outlet not locate the detector near sources of steam or oil not aim the detector such that it will receive direct or mirror sunlight there are pets on the premises use the pet alley lens not limit the coverage by large objects within the area such as plants or filing cabinets Flow Sun open the case use a small flat blade screwdriver and push in the tab at the bottom of the case and pull cover straight out at the bottom Loosen the printed board screw and push the board up as far as it will Using a small screwdriver remove the appropriate for the mounting screws Remove the left and right wiring entrance knockouts located at the top of backplate Mount the backplate using the screws HEIGHT CHART FOR FULL RANGE CORRIDOR CURTAIN ALLEY 3 m m 2.4 m 2.1 m 1.8 m 1.5 m 1.2 m Range and dead zones may vary due to settings the Mounting Height chart set the vertical to get the desired coverage Ensure that the retaining screw is tightened just enough to prevent movement the circuit board DOWN will increase the far and bring the near beams closer to the mounting Moving the circuit board UP will reduce the far and move the near beams farther out from the wall Moving the circuit board UP too much will the far beams to above the target as a the range may appear shorter J1 will enable disable the alarm LED If J1 is the LED will not operate on alarm If J1 is ON the LED operate on alarm JUMPER J2 selects between and operation For a typical environment unit should be set on J2 ON If the environment potential disturbances that cannot be avoided J2 to OFF for operation The corridor lens should not be used in a that is less then 10.5 3.2 m wide Ensure the are aimed directly down the centre of the With the corridor lens set J2 to LENSES Bravo 3 is supplied with the lens To the lens release the top tab and pull the lens out This action releases the lens Insert the lens the GROOVES FACING INWARD The bottom of the is indicated by two triangular indentations Ensure the lens is centred left to right then reinstall the lens The lens holder will snap into place sealing the into position mA VDC mA VDC mA VDC TESTING Once the detector has been set up walk test the entire where coverage is desired Should the coverage be re adjust or relocate the detector to obtain full Once coverage is as required the alarm LED be disabled by setting J1 to OFF NOTE Upon installation the unit should thoroughly tested to verify proper operation The user should be instructed on how to perform walk and should walk test the detector regularly and DM W Mounting Brackets the optional DM W Wall Mount and DM C Ceiling brackets to solve difficult placement problems The and DM C mount to either the wall or ceiling and for full vertical and horizontal positioning of the detector the detector can be tilted up or down and through 90 to obtain the best position for optimal The Bravo PIR has been designed to be fully with the DM W and DM C brackets Contact DSC distributor for more information KNOCKOUTS SCREW FOR ADJUSTMENT 12V GND NC C ON LED ON OFF LED OFF SENSOR ON FAST OFF SLOW MOUNT MOUNT 12V GND NC C shown power applied no alarm SECURITY CONTROLS LTD Flint Road Downsview Ontario M3J 2J6 665 8460 Fax 416 665 7498 DIGITAL SECURITY CONTROLS LTD CANADA 10 1994 R4

Related Files