Notes Pager Reporting Residential Dial Private Line Dial PC1616 1832 1864 V4.2 SERIES PC1616 1832 1864 V4.2 PowerSeries control panels can be programmed to report any event to a digital pager using Pager or phone using Residential Dial or Private Line Format This application note will describe the required to report openings and closings to a pager It can also be used for sending alarms to off site telephone the pager feature is a five step process the pager phone number the account number the communicator format the communicator call direction options the reporting codes Sections 302 311 318 350 351 376 320 349 601 608 Number 2 Account Numbers Format Option Call Direction Options Codes Codes 1 Program the Pager Telephone Number phone number 1 is used to report events to the central station if required and phone number 2 is for pager applications Program the pager cellular phone number in Section 302 for Pager Format pauses are required after entering the number to allow the pager company to the call and give the signal beeps at which point the panel will transmit the account number and code a HEX E at the end of the phone number for a 2 second pause A number of pauses may be for example enter 4 E for an 8 second pause To determine the length of the pause required the pager phone number with a premise phone two or three times to determine the delay required are not required for Residential Line or Private Line Format 2 Program the Partition Account Numbers panel will transmit the partition account number when communication partition events Program the account numbers in sections 311 318 3 Program the Communication Format data 05 in Section 350 for phone number 2 for pager format data 06 in Section 350 for phone number 2 for residential dial data 09 in Section 350 for phone number 2 for private line Only alarms events will be transmitted for Private Line format Page 40 4 Program the Reporting Codes panel will report the 2 digit reporting code programmed There are no special requirements any 2 digit can be programmed for any event A simple pattern should be used i e code 21 for opening by 1 22 for user 2 etc the reporting codes required in Section 320 to 349 and 601 to 608 The panel cannot send HEX digits to the pager If a HEX digit is programmed the panel will the digit When transmitting events to both the central station and pager the panel must be to report to the central station using either using automatic SIA or automatic ID The panel will ignore the programmed data and transmit the correct signal to central station Only alarms events will be transmitted for Private Line format 5 Program the Communicator Call Direction Options Call Direction options are used to determine which events will be reported to which phone By default all events are programmed to report all events to phone number 1 To program and closings to phone number 2 on partition 1 enter Section 367 and turn option 1 OFF do not phone number 1 and turn option 2 ON call phone number 2 partition 2 to 8 are being used program Section 368 374 to change the Communicator Direction options for partition 2 to 8 events Only alarms events will be transmitted for Private Line format Tips the pager does not receive a signal ensure a long enough delay is programmed in the phone number allow the pager company time to pick up the phone and give the signal beeps The panel will only make one attempt to page any event The panel cannot transmit HEX digits A to F When paging opening and closing signals the panel will not transmit the closing event until after the exit expires Test the panel and wait for the exit delay to expire Verify the pager receives the closing event Disarm the and verify the pager receives the opening event Page 41

Related Files