DSC CFP 152 CFP 155 IS EN NA
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-cfp-152-cfp-155-is-en-na-6981504723.pdf |
---|---|
Type | |
Size | 664.29 KB |
Downloads |
Text Preview
Limited Warranty warrants that for a period of one year from the date of purchase the product shall be free defects in material and workmanship under normal use and that in fulfillment of any breach such warranty DSC shall at its option repair or replace the defective equipment upon return the equipment to its repair depot This warranty applies only to defects in materials and and not to damage incurred in shipping or handling or damage due to causes the control of DSC such as lightning excessive voltage mechanical shock water dam or damage arising out of abuse alteration or improper application of the product foregoing warranty shall apply only to the original buyer and shall be in lieu of any and all warranties whether expressed or implied and of all other obligations or liabilities on the of DSC This warranty contains the entire warranty DSC neither assumes responsibility nor authorizes any other person purporting to act on its behalf to modify or to change this nor assume for it any other warranty or liability concerning this product no event shall DSC be liable for any direct indirect or consequential damages loss of profits loss of time or any other losses incurred by the buyer in connection with the installation or operation or failure of this product recommends that the entire system be completely tested on a regular basis However frequent testing and due to but not limited to criminal tampering or electrical dis it is possible for this product to fail to perform as expected INSTRUCTIONS Zone Input Module CFP 152 Zone Input module converts the two zones on the CFP 102 fire alarm con panel from Class Style to Class Style The CFP 155 Zone Input module the five zones on the CFP 105 fire alarm control panel from Class Style to Style 24 VDC nom current CFP 152 2 mA CFP 155 5 mA current 60 mA max Resistance 100 max per zone 20 100 each This component must be included in the control panel battery calcula Refer to the Standby Battery Calculation Sheet PN 29005851 with the control panel Digital Security Controls Ltd Canada cid 127 1 800 387 3630 cid 127 www dsc com in Canada 29005825 R001 CFP 152 155 module mounts in the corre CFP 102 105 fire alarm back box to Figure 1 Place the supplied spacers 2 on the pem the module header pins into the cor Class zone terminals on the board Secure the module to the the studs with nuts provided 2 Connect the electrical common wire on module to the terminal on the panel Tighten all zone terminal screws to ensure electrical connections between the panel and the CFP 152 155 module to the CFP 102 or CFP 105 Installation for instructions on zone program and mixing smoke detectors and con alarm initiating devices on the same