DSC cfp-500 v1-0 im eng

File Preview
File Preview
Click below to download for free

File Data

Name dsc-cfp-500-v1-0-im-eng-6324817590.pdf
Type PDF
Size 847.29 KB
Downloads

Text Preview

CFP 500 Line Dialer 1.0 This manual contains information on limitations regarding use and function and information on the limitations as to liability the manufacturer The entire manual should be carefully read of Contents 1 Introduction 1 General Features of the CFP 500 1 Codes Standards and Installation Requirements 1 Technical Support and General Information 2 2 Installing and Wiring the CFP 500 3 Unpacking the CFP 500 3 Wiring the CFP 500 3 3 CFP 500 Operation 5 LED Indicators 5 Communication with the Fire Alarm Control Panel 5 Phone Line Communication 5 4 Programming the CFP 500 6 How to program using the CFP 550 Handheld 6 DLS Programming 12 Panel Programming Section Descriptions 12 5 Programming Worksheets 16 Dialer Programming Worksheets 16 Panel Programming Worksheets 21 6 Warranty and Warning Information 22 Warning 22 Limited Warranty 24 Appendix A Table of Reporting Codes 25 Appendix B Table of Compatible Receivers 27 CFP 500 is a dual line dialer that will communicate all alarms supervisory and trouble conditions to a Central Station using ID SIA or 10 20 bps communication formats The CFP 500 will support the CFP 102 or CFP 105 Fire Panel The Handheld Programmer must be used to program the CFP 500 Dialer General Features the CFP 500 1 Introduction all zone alarm supervisory and trouble conditions all panel troubles through CFP 550 Handheld Programmer 10 20 bps SIA Contact ID and Pager Formats telephone numbers programmable test transmission reporting codes for SIA and Contact ID formats buffer with date and time stamp call directions by group shutdown options available for all events Module current rating 40mA standby 65mA when dialing Module voltage rating 19 VDC to 27.5 VDC Codes Standards Installation Relevant Codes and Standards CFP 500 Dual Line Digital Dialer is designed to meet the DACT requirements of NFPA 72 edition UL 864 Control Units for fire Protective Systems 1996 edition and in Canada Standard for Control Units for Fire Alarm Systems 1999 edition General Installation Requirements Documents installing the CFP 500 refer to this manual and the manual for the control panel into this module is being installed This dialer requires programming Programming is done the CFP 550 programmer Refer to the CFP 550 operating instructions for details on pro using the CFP 550 Wiring wiring recommendations in these documents are intended as guidelines All field wiring be installed in accordance with NFPA 70 National Electrical Code and in Canada with most current National Electrical Code and with all relevant local codes and standards and Authority Having Jurisdiction Technical and technical support from DSC Call toll free 1 800 387 3630 Canada US general product information visit our web site www dsc com System Verification complete fire alarm system must be verified for proper installation and operation when initial installation is ready for inspection by the Local Authority Having Jurisdiction system component is added changed or deleted programming changes are made wiring has been altered or repaired failure due to external influences such as lightning water damage or extended outages has occurred Standby Power CFP 102 CFP 105 Fire Panel provides standby battery support for lead acid rechargeable The required capacity of the standby batteries must be calculated using the charts tables within the CFP 102 CFP 105 Installation Manual for the period as required by or local codes and standards Even though the calculation table within the CFP 102 Installation Manual includes a safety margin lead acid batteries commonly used for can have variable capacity as a result of age and ambient conditions Periodic for damage and the batteries ability to support the attached equipment is highly 2 Installing and Wiring the Unpacking the basic CFP 500 package includes the following components polarized locking cable assembly 4 self locking nuts manual nylon spacers Wiring the Ensure that standby calculations are done before installing the dialer See the Fire Panel Installation Manual for all power information and calculation The current rating for the CFP 500 is mA standby current mA alarm current when dialing Mount the CFP 500 CFP 500 is located inside the main panel cabinet according to the following diagram Connect the CFP 500 CFP 500 requires connection of the Secur bus from the dialer to the main panel using the 4 pin polarized locking cable assembly Up to two telephone lines are connected to Tip Ring T1 R1 terminals the dialer according to the following diagram 3 CFP 500 Operation LED Indicators dialer operating status is visible from its five LED indicators These indicators are located the dialer Each indicator is described in the following table Color when Fault Secur bus connection to the main panel has failed Trouble Trouble Trouble Watchdog is a trouble on telephone line 2 is a trouble on telephone line 1 dialer is unable to communicate dialer is functioning normally LED flashes second second off Communication the Fire Control Phone Line connected to the FACP properly the Watchdog LED will flash at a rate of second on when power is applied to the FACP The dedicated dialer will transmit all events that occur the FACP if programmed to do so Any troubles that occur on the dedicated dialer will be on the appropriate LED and communicated if enabled as well as causing a common condition on the FACP If the FACP should lose communication with the dialer a com trouble condition will also be generated dedicated dialer is equipped with two phone line connections When an event occurs that communications the first attempt at dialing will be on telephone line 1 If the fails the dialer will then select telephone line 2 for the next attempt at dialing This continue until the maximum number of dialing attempts is reached Please note that on first attempt to telephone line 1 if a telephone line trouble exists on line 1 and not line then the first attempt will start on line 2 4 Programming the CFP 500 How to program the Connect the CFP 550 to the Dialer CFP 550 connects to the dialer via the RJ 11 jack mounted on the dialer An RJ 11 con cable is provided with the handheld programmer Refer to the wiring diagram in the CFP 500 on page 4 for the location of the RJ 11 jack the programmer is connected it will power up and remain idle until programming is initiated Programming using the CFP 550 program follow these steps 1 Press programmer display will read Module Address dialer module address 11 control panel address 02 2 Enter 11 for example programmer display will read Installer Code The default code 2600 3 Enter the installer code display will read Section Number 4 Enter a valid 3 digit programming section number to program that section 5 Enter the programming data required by the selected programming section Use the arrow t

Related Files