DSC CO-CRD - Installation Manual - English - Communique Central Office Expansion Card

File Preview
File Preview
Click below to download for free

Text Preview

Central Office Card Instructions Communiqu Central Office Card is an optional expansion module which the total number of telephone lines by two with the addition of each Up to three central office cards can be added to the system for a total of lines the Central Office Card connect the first central office card to the Communiqu Control Unit perform following Fasten the four standoffs provided with the central office card to the four on the control unit Place the station card on top of the standoffs and use the four nuts provided secure it into place see Figure 1 below Connect one end of the ribbon cable provided with the central office card to pins located on the central office card Connect the other end of the cable to the pins labelled 3 4 on the control unit located above the central office card see Figure 2 below Ensure that all make contact with the connector sockets and line up all pins with the before pushing them into place When connecting the second and third central office cards perform steps with one exception the ribbon cable will be connected to the pins 5 6 on the control unit for the second card and 7 8 for third card 1 2 damage could result to the central office card or the control if the connections are offset You must ensure that proper are made before applying power to the control unit the Central Office Card central office card programming is outlined in the Communiqu Installation and manuals Please refer to the System Installation Manual for on limitations regarding product use and function and on the limitations as to liability of the manufacturer COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Controls Ltd could void your to use this equipment REN 1.2 Network Ports 02LS2 equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential This equipment generates uses and can radiate radio frequency energy and if not installed and used in with the instructions may cause harmful interference to radio communications However there is no that interference will not occur in a particular installation If this equipment does cause harmful interference radio or television reception which can be determined by turning the equipment off and on the user is encouraged try to correct the interference by one or more of the following measures Re orient the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio television technician for help user may find the following booklet prepared by the FCC useful to Identify and Resolve Radio Television Problems This booklet is available from the U S Government Printing Office Washington D C 20402 004 000 00345 4 INFORMATION equipment complies with Part 68 of the FCC Rules On the side of this equipment is a label that contains among information the FCC registration number of this equipment TO TELEPHONE COMPANY The customer shall notify the telephone company of the particular to which the connection will be made and provide the FCC registration number and the ringer equivalence of the circuit Registration Number F53CAN 24626 MF E REN 1.4B Jack RJ11C CONNECTION REQUIREMENTS Except for the telephone company provided ringers all to the telephone network shall be made through standard plugs and telephone company provided jacks or in such a manner as to allow for easy immediate disconnection of the terminal equipment Standard jacks be so arranged that if the plug connected thereto is withdrawn no interference to the operation of the equipment the customer premises which remains connected to the telephone network shall occur by reason of such OF HARM Should terminal equipment or protective circuitry cause harm to the telephone network the company shall where practicable notify the customer that temporary disconnection of service may be however where prior notice is not practicable the telephone company may temporarily discontinue service if action is deemed reasonable in the circumstances In the case of such temporary discontinuance the telephone shall promptly notify the customer and will be given the opportunity to correct the situation TELEPHONE COMPANY INFORMATION The security control panel must be properly connected the telephone line with a USOC RJ 31X telephone jack FCC prohibits customer provided terminal equipment be connected to party lines or to be used in conjunction with telephone service Interconnect rules may vary from state to state IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone company may make in its communications facilities equipment operations or procedures where such actions are reasonably and proper in its business Should any such changes render the customer terminal equipment incompatible the telephone company facilities the customer shall be given adequate notice to the effect modifications to uninterrupted service EQUIVALENCE NUMBER REN The REN is useful to determine the quantity of devices that you may to your telephone line and still have all of those devices ring when your telephone number is called In most not all areas the sum of the RENs of all devices connected to one line should not exceed five 5.0 To be certain of number of devices that you may connect to your line you may want to contact your local telephone company MAINTENANCE FACILITY If you experience trouble with this telephone equipment please contact facility indicated below for information on obtaining service or repairs The telephone company may ask that you this equipment from the network until the problem has been corrected or until you are sure that the is not malfunctioning Security Controls Ltd 160 Washburn St Lockport NY 14094 Order Code 9.0F Digital Security Controls Ltd Flint Road Downsview Ontario Canada M3J 2J6 665 8460 1 800 387 3630 in Canada 29002327 R1

Related Files