DSC COMMUNIQUE v1 0 - Installation Manual - English - Communique Phone System

File Preview
File Preview
Click below to download for free

Text Preview

System Introduction Processor Board Eight stations expandable to 24 Two telephone lines expandable to eight A 100 call log of caller name number time and date call can be viewed at any telephone station call feature must be enabled by local telephone Four programmable outputs can be programmed to when any or a selected line rings when a is performed or to activate an electric door from any telephone or internal intercom station RCA input connect audio equipment for an external of system background and hold music Paging output In addition to using built in telephone intercom speakers connect additional external for paging Emergency jack A backup analog telephone to an emergency telephone jack on line 1 can be used in the event of complete AC and failure Super cap memory retention maintains all for up to one week in the event of a power failure Overcurrent transient and lightning surge circuit Requirements 29VDC 2A included Two 12V 7Ah rechargeable gel cell batteries Digital Message Center Card Adds 24 private mailboxes and one system mailbox voice messages One recorded greeting per station mailbox five system greetings 100 message buffer records message caller number date and time call display must be enabled by local telephone company Three answering modes Normal Automated and Night Sentry Messages can be retrieved from a remote location saver feature provides indication of new when calling from remote locations Messages can be sent to other station mailboxes the SIMM Memory Module Hold the TSVPCBRD with the Memory Module socket the left hand side and up 1 Insert the SIMM Memory into the socket with 1 at the bottom and PIN at the top as shown Press SIMM Memory Module into place until clips lock the into place Telephone Station Eight incoming telephone Line keys 24 Station keys 19 function keys 32 character alphanumeric backlit display with brightness and contrast 16 character programmable station and line labels All keys are backlit with adjustable brightness System programming accessible from any telephone Multiple security Personal Identification Numbers to prevent unauthorized access to remote access room monitoring and of a door station Prime line access program stations to automatically a specific line when the handset is lifted or the key is pressed from a telephone in its idle Loud bell control program lines to activate an bell on incoming calls Choice of four ring styles for audible station Line callback and camp on will notify the user when a telephone line becomes free System and Exclusive hold a call which can be on hold can be retrieved system wide or from initiating station respectively Hold and transfer recall a call placed on hold or to another station will recall the initiating if not answered after a programmed period of Executive override enables user to interrupt any line feature may be PIN protected to prevent use Alarm clock select radio or chime alarm program to seven day schedule Installation Manual 1 1 Infrared receiver passes signals from any infrared TV VCR etc to transmitters located in the building to control infrared devices DTMF and pulse signaling Automatically displays AC and battery trouble Optional wall mounting a complete description of these and other functions and their operation please consult Communiqu Operation Manual Cards Station Card Central Office Card eight additional stations per up to two station cards can be to the system for a total of 24 two additional telephone lines card up to three central office can be added to the system for total of eight telephone lines Cards Security Interface Card telephone access to a or Power832 security operates associated X 10 devices provides voice prompts for security programming and operation and feedback of status Modem Card for SMDR Station Message Recording reporting and for factory system diagnostics Stations Internal Intercom Station Handsfree microphone and speaker for two way volume control Do not disturb setting programmable from any station Door Intercom Station Handsfree microphone and speaker for two way Doorbell button will sound door chime at programmed Door stations can be programmed to be forwarded to off premise telephone number Dual Analog Interface Units an interface between the digital telephone and two analog telephone devices such as fax computer modems and cordless standard telephone sets This device will save having to a separate telephone line for each device Each occupies a separate station of the Box sure that the following components are included your telephone system one Communiqu control unit and cabinet one Installation Manual and one Operation Manual for end user one message center card installed ground connection assembly battery jumper wire cabinet lock with clip Communiqu Installation Manual Started Steps installing the Communiqu we recommend working a plan Create a diagram which includes the location all telephone sets intercom and door stations and the unit Working in this manner will greatly reduce the installation and troubleshooting time required to the system up and running installed the system should be thoroughly tested to proper operation Descriptions Connection BATT 12V 7Ah rechargeable gel cell batteries in series see are used as a backup source of power in the of an AC power failure the RED battery lead the control panel to the battery terminal of one connect the BLACK lead to the negative terminal of the other Connect the other two with the jumper wire battery must be connected before the AC source Do not apply power until all other is complete Jack AC Communiqu requires a 29V 2 A power supply Plug Power Supply into a 120V AC outlet and then plug the supply into this jack located at the bottom right of control panel the battery before you connect AC Do not power until all other wiring is complete AC cord must be to the cabinet with tie wrap supplied to damage to the jack the cord is inadvertently Please consult for further detail Outputs through 4 O P 1 4 terminal provides a switch to ground when to activate devices requiring power Connect positive side of any device to 12VDC and the negative the output terminal on the control unit Connect the of the 12V power supply to the output terminal the output is activated the connection will be made power the device 2 Output PAGE O P paging output is designed so that a speaker can be to the system In addition to the speakers on the and intercoms the external speaker will an all page Using RCA type connectors and connect one plug to the PAGE O P output jack on control panel and the other to the input jack of the audio amplifier see diagram below Input AUDIO I P Jack Mono Audio equipment may be connected the RCA Audio input jack to provide a source of and hold music Equipment with a line out be connected to the central processor board using an type plug for the Audio Input jack and a plug for the music source Below are two examples different types of audio equipment each requiring a output plug These plugs and cables are not with the Communiqu Jack

Related Files