DSC CP-5M - Installation Manual - English - 2 Zone Alarm Control Panel
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-cp-5m-installation-manual-english-2-zone-alarm-control-panel-2069518734.pdf |
---|---|
Type | |
Size | 643.39 KB |
Downloads |
Text Preview
CP 5M Alarm Control Panel DSC model CP 5M Alarm Control Panel is designed with features make it ideal for a wide range of residential and commercial alarm applications Amp power supply 12 volt 1 amp regulated power supply Circuit Provides 45 second exit delay and adjustable entry 0 90 seconds Can be activated with both normally open normally closed contacts Instant Delay Circuit Provides entry delay only if circuit has been alarmed first otherwise it alarms instantly be activated with either normally open or normally closed Instant delay circuit can be converted to a conventional circuit Panic Circuit Normally open latching audible panic Siren Driver When activated by cutting a circuit board mounted it allows the use of an 8 ohm speaker as a signal device Reset and Adjustable Cut off Alarm cut off is factory set 4 minutes and is can be set by the installer for 8 or 15 minutes Alarm automatically re arm upon closing for subsequent alarms Memory Green circuit status light on panel and remote terminal flash during and after an alarm until control panel reset Inhibit Alarm control cannot be armed unless alarm are in the non alarm state green status light is ON Contacts 3 amp SPDT alarm contacts Arming Station Terminals Output terminals are provided pre alarm indicator arming key loop status and system armed SUPPLY power supply utilises a reliable single chip adjustable voltage with built in 1 amp current limiting and thermal overload The output voltage is factory set to 13.6 volts to the correct charging voltage for a 12 volt gell type battery On the CP 5 6V 6 volt control panel the output is set for 6.8 volts to provide the correct charging for a 6 volt rechargeable battery The alarm control and auxiliary power output POS and NEG terminals are for 1 amp The siren and bell output is separately fused for amps required is 30 VA 14 16 VAC Model CP 5 6V requires 20 VA 10 12 VAC transformer The current available at the power output terminals for operating motion detectors communicator and other equipment is 800 mA draw This leaves sufficient continuous current available operating the panel remote indicators and for charging the Where the total current required for operating all devices to the CP 5M during an alarm period is less than 1 the power supply will provide all the current required and stand by battery will only be used in the case of an AC power However if the power required during an alarm period is than 1 amps the balance of the current will be drawn the battery After the alarm period the battery will be recharged CIRCUITS CP 5M alarm control panel has 2 alarm circuits delay and plus a normally open 24 hour panic circuit Both the and instant delay circuits can be activated by normally or normally open contacts as shown in the connection Both circuits have a factory set 45 second exit time during either loop may be tripped after arming the panel without an alarm This allows one to arm the system and exit the The delay circuit has an adjustable entry time 0 to 90 during which the alarm is delayed to allow and authorised to enter the premises and disarm the control panel without an alarm During the entry delay period the same alarm is maintained when the instant delay circuit is tripped provided the delay circuit has been tripped first If the instant delay circuit tripped before the delay circuit the entry period will not be and the panel will go into alarm instantly The delay and instant delay circuit combination is very useful in providing route of exit and entry through a door connected to the delay and through motion detectors connected to the instant delay without causing an instant alarm however that entering the premises by a route other than the door connected to the delay loop will cause an instant If the instant delay circuit is not required it may be converted a normal instant circuit by cutting the two blue jumpers on the board Cutting the two jumpers removes the exit and entry period from the instant delay circuit 24 hour panic circuit may be activated by closing a momentary normally open push button connected between the Panic NEG terminals as shown in the connection diagram AND DISARMING alarm panel is disarmed by closing a maintained key switch between the KEY and NEG terminals as shown in the diagram The panel is armed when the switch is in the position An alarm on the delay or instant delay loop is reset disarming the panel closing the key switch alarm on the panic circuit is reset by arming and disarming the if the panel was disarmed when the panic alarm occurred panic alarm is reset by disarming the panel if the panel was when the panic alarm occurred The panic alarm cannot silenced with the panic circuit closed CP 5M alarm panel is designed with an arming inhibit feature prevents arming of the panel if either the delay or instant delay are in the alarm state The green loop status light will be OFF either circuit is in alarm The alarm panel is armed when the red light comes ON The arming inhibit feature prevents false alarms caused by attempting to arm the panel with or more circuits in the alarm condition circuits automatically re arm upon reclosing If an alarm goes into the alarm state it will automatically re arm for alarms when it resets If one circuit has gone into the alarm and remains in that condition after the alarm cut off period remaining circuit will still create an alarm should is go into the state 1992 29000056 R1 ORANGE jumper to activate siren driver the two BLUE jumpers to the INST DLY circuit to conventional instant circuit CUT OFF TIME cut off time is factory set for minutes change to 8 minutes cut lead to the right of the change to 15 minutes cut leads to the right of the and PANEL OUTPUTS CP 5M provides terminal outputs for loop status indicator indicator and pre alarm signal All three are positive outputs current limited by a 100 ohm resistor The short current draw from these outputs is therefore approximately mA The output voltage drops 1 volt for every 10 mA of output Therefore at 30 mA output current the output voltage be 10 volts The green loop status indicator and voltage is ON when the alarm circuits are in the non alarm state red arming indicator and voltage output are ON when the is armed The pre alarm signal output is present when the panel is in the entry delay timing period When the control is in the alarm condition a voltage will appear at the SIREN for operating a bell or other signalling device The relay is also activated during the alarm cycle activating the amp SPDT dry contacts The alarm will cut off after a 4 minute This cut off period may be changed to 8 or 15 minutes by a resistor on the circuit board as shown on the connection The green loop status indicator will flash during and an alarm has occurred to act as an alarm memory until the panel has been reset INSTRUCTIONS on Power sure to discharge any static voltage by touching a ground before touching the panel circuit board Make all connections to the panel before connecting the battery or Disarm the panel by closing the key switch If 8 ohm are being used as alarm signals be sure that the orange is cut to activate the built in siren driver Connect the to the AC terminals With the panel reset alarm not sounding check the voltage on the red and black leads The voltage should be 13.6 volts 6.8 volts for the If the voltage is less than 13.0 volts or 6.8 volts for the check the current load on the auxiliary power terminals ensure that the proper transformer is being used If the is correct connect the red battery lead to the positive of the battery and the black battery lead to the negative post Reversing the battery leads will blow the siren fuse and if left connected will damage the battery and Disarming to see if the green loop status light is ON and the red armed light is If the green light is flashing momentarily arm and disarm the panel opening and closing the key switch If the green status light is OFF check alarm circuits for opens and shorts to negative If the green status light to flash check for a short between the panic terminal and the