DSC DAI-CRD - Installation Manual - English - Communique Dual Analog Interface
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-dai-crd-installation-manual-english-communique-dual-analog-interface-7194508263.pdf |
---|---|
Type | |
Size | 633.77 KB |
Downloads |
Text Preview
LIMITED WARRANTY Security Controls Ltd warrants that for a period of twelve months from the date of the product shall be free of defect in materials and workmanship under normal use and in fulfilment of any breach of such warranty Digital Security Controls Ltd shall at its option or replace the defective equipment upon return of the equipment to its repair depot This applies only to defects in parts and workmanship and not to damage incurred in shipping handling or damage due to causes beyond the control of Digital Security Controls Ltd such as excessive voltage mechanical shock water damage or damage arising out of abuse or improper application of the equipment foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and other warranties whether expressed or implied and of all other obligations or liabilities on the of Digital Security Controls Ltd This warranty contains the entire warranty Digital Security Ltd neither assumes nor authorizes any other person purporting to act on its behalf to or to change this warranty nor to assume for it any other warranty or liability concerning product no event shall Digital Security Controls Ltd be liable for any direct indirect or consequential loss of anticipated profits loss of time or any other losses incurred by the buyer in with the purchase installation or operation or failure of this product Digital Security Controls Ltd recommends that the entire system be completely on a regular basis However despite frequent testing and due to but not limited to criminal or electrical disruption it is possible for this product to fail to perform as expected COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Products Ltd void your authority to use this equipment equipment has been tested and found to comply with the limits for a Class B digital device to Part 15 of the FCC Rules These limits are designed to provide reasonable protection harmful interference in a residential installation This equipment generates uses and can radio frequency energy and if not installed and used in accordance with the instructions cause harmful interference to radio communications However there is no guarantee that will not occur in a particular installation If this equipment does cause harmful to radio or television reception which can be determined by turning the equipment and on the user is encouraged to try to correct the interference by one or more of the measures Re orient the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is Consult the dealer or an experienced radio television technician for help user may find the following booklet prepared by the FCC useful to Identify and Radio Television Interference Problems This booklet is available from the U S Printing Office Washington D C 20402 Stock 004 000 00345 4 Security Products Ltd 160 Washburn St Lockport NY 14094 Digital Security Controls Ltd Canada www dscgrp com in Canada 29002325 R004 Analog Unit Instructions Communiqu Dual Analog Interface DAI unit acts as an interface between the telephone system and two analog telephone devices such as fax machines modems and cordless or standard analog telephone sets This device will having to install a separate telephone line for each device Up to eight DAI units be installed per system for a total of 16 analog stations and Connecting the DAI unit Locate the area to which the DAI unit will be mounted Fasten the two screws to the wall making sure that they are the same distance as the mounting holes on the back of the unit Place the DAI unit over the screws and then press down towards the floor to secure it into place diagram below Once the DAI unit is mounted to the wall the telephone can be made Using 4 conductor cable with RJ 12 plugs on each end run a cable from the Station In to a station jack on control unit Run two other cables from the Station A B Out jacks to two separate analog telephone see diagram below units can only be connected to Stations 10 17 on the Communiqu unit Unit Programming DAI unit can be connected to two analog devices occupying two separate The first device will belong to the station to which the interface unit is to the second device will be assigned to a station programmed in section second device can be assigned to any empty station from 18 33 The DAI units can only be connected to stations 10 17 We therefore recommend that the devices be assigned to stations 18 33 so as to leave other stations free for interface units required program the second analog station enter installer programming by pressing PGM key three times Press the Line 4 key The display will read the Station 12 key again The display will read the flashing Line 4 key again The display will read Second a DAI 10 Station NONE a Second NONE 10 Station 33 keys 10 through 17 will turn ON If DAI units are connected to one or more of 10 17 the corresponding Station key will be flashing quickly view the programming status of the first eight stations press each of the lit Station one at a time If the Station 10 key is pressed the key will flash slowly and the will read program the second station for station 10 press the Station 10 key again The will read stations that are available to be used as a second station will turn ON A Station key is not lit represents a station that is already in use and may not be assigned as a station To select the second station press the corresponding Station key for Station 33 The key will begin to flash quickly and the display will read the PGM key to save the new setting The display will return to the a Station prompt a modem or fax machine is connected to a DAI station the Bell feature must be turned off for the corresponding station see Control in the Communiqu Operation Manual for details Station Programming programming is required when connecting fax machines to the system When an incoming fax call is answered by the message the fax tones are detected and the call is automatically routed to the fax one fax machine can receive faxes per system via the automatic feature program a station for a fax machine enter installer programming by pressing PGM key three times Press the Station 12 key The display will read Fax a fax station has been programmed or Station XX Station Enabled there is no fax station Station keys corresponding to stations which are connected to DAI units will be lit solid or flashing If these units have a second station programmed those keys will also be either lit solid or flashing If the Station key is flashing the is programmed as a fax station if the key is lit solid the station is not as a fax station stations must be programmed one at a time To program a fax station press the lit Station key The key will start flashing quickly and the display will read disable the fax station feature at a station press the corresponding flashing key The key will be lit solid and the display will read Station XX Station Enabled Station Cadence a DAI save any programming changes press the PGM key fax station must be programmed to have Only for all system see Ringing and Access in the Communiqu Installation for details Cadence Programming DAI Unit can be programmed to ring with different cadences This is done by the Time of the ringing cycle for each analog station program the ringing cadence enter Installer programming by pressing the PGM three times Press the Line 2 key twice Press the Station 25 key The display read the Station 25 key again The display will read the