DSC DG-50 Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name dsc-dg-50-installation-instructions-4290638715.pdf
Type PDF
Size 827.33 KB
Downloads

Text Preview

DG 50 Detector Instructions DG 50 is an acoustic glassbreak detector designed to listen for the specific sonic of breaking glass The DG 50 is equipped with multi level discriminating to maximize its response to breaking glass and minimize its response to nor environmental noises The DG 50 is extremely resistant to seismic shock and will alarm in response to a slamming door or even a tap on the case input 9 16 VDC Ripple 1 V P P max 15 mA 12 VDC Temperature 14 to 122 10 to 50 non condensing 95 max RH Rating 24 VDC 100 mA max Duration 3 seconds sensitivity 35 x 35 10m x 10m sensitivity 10 x 10 3m x 3m l x w x h 3.5 x 2.5 x 0.8 89 x 64 x 20 mm Information Form A alarm contact Form A alarm contact and tamper contact Form C alarm contact and tamper contact The Detector Test the detector thoroughly proper placement using the AFT Glassbreak Simulator Other may trip the unit but will provide accurate indications For optimum protection the detector have a direct line of sight to protected glass To ensure glassbreak detection for glass the DG 50 must be directly in front of the sur to be protected at a maximum of 12 and a minimum dis of 5 For difficult applications or where the protected glass is greater than 12 3.6m from the sensor use the DSC Acuity AC 100 Glassbreak Detector for glass Window coverings will absorb sound energy from the shattering glass In these mount the detector as close as possible to the protected glass either on an wall the ceiling or behind the window covering if possible The detector should be mounted at least 1.8m 6 feet off the ground Do not mount the detector on the wall as the protected glass to the diagram for correct incorrect mounting locations Avoid installation near such as speakers or other which produce sounds Do not install the detector beyond the maximum recommended range even if the simulator shows additional range future changes in room acoustics could that additional range Application on 24 hour loops should be avoided unless the location is unoccupied Test false alarm immunity by creating any sounds in the room which will likely when the alarm system is armed choosing a location for each DG 50 glassbreak detector the following test be performed to ensure that it is mounted in the best possible location a location and remove the front cover of the detector Use double sided tape to mount the detector in the selected location Use a 9 volt battery to power detector Glassbreak Simulator AFT 100 glassbreak simulator generates plate or tempered glass samples Use the glass setting if you are unsure of the glass type Observe the following when test the detector The correct mounting location is indicated by three successive detections If the does not respond each time relocate the detector and repeat the test the windows in question are covered by drapes or blinds place the tester behind the window coverings If the drapes prevent reliable detection we suggest that the be mounted behind the drapes either on an adjacent wall or on the ceiling there are multiple windows or one large window activate the tester at the furthest on the glass the sensitivity is too high turn the adjustment counter clockwise if reliable detec is not achieved increase the sensitivity by turning the adjustment clockwise should not be adjusted any higher than necessary to achieve reliable the detector responds consistently it can be permanently mounted using the sup screws the DG 50 the location has been determined the detector by pressing the release on the bottom with a small flat blade Remove the cover and set in safe location Draw the wires through rectangular opening in the backplate connect block polarity for power wiring the detector using the two mount screws Once the detector is perma mounted replace the cover and repeat the installation tests using the AFT 100 to confirm proper operation READ CAREFULLY DSC Software purchased with or without Products and is copyrighted and is purchased under the following license terms End User License Agreement is a legal agreement between You the company individual or entity who the Software and any related Hardware and Digital Security Controls a division of Tyco Safety Products Can Ltd the manufacturer of the integrated security systems and the developer of the software and any related or components which You acquired the DSC software product PRODUCT or is intended to be accompanied by HARD and is NOT accompanied by new HARDWARE You may not use copy or install the SOFTWARE PRODUCT SOFTWARE PRODUCT includes computer software and may include associated media printed materials and or electronic documentation Any software provided along with the SOFTWARE PRODUCT that is associated with a separate end user license agree is licensed to You under the terms of that license agreement installing copying downloading storing accessing or otherwise using the SOFTWARE PRODUCT You agree to be bound by the terms of this EULA even if this EULA is deemed to be a modification of any previous or contract If You do not agree to the terms of this EULA DSC is unwilling to license the SOFTWARE to You and You have no right to use it PRODUCT LICENSE SOFTWARE PRODUCT is protected by copyright laws and international copyright treaties as well as other intellectual laws and treaties The SOFTWARE PRODUCT is licensed not sold GRANT OF LICENSE This EULA grants You the following rights Software Installation and Use For each license You acquire You may have only one copy of the SOFTWARE installed Storage Network Use The SOFTWARE PRODUCT may not be installed accessed displayed run shared or used on or from different computers including a workstation terminal or other digital electronic device In other words if You have several workstations You will have to acquire a license for each workstation the SOFTWARE will be used Backup Copy You may make back up copies of the SOFTWARE PRODUCT but You may only have one copy per installed at any given time You may use the back up copy solely for archival purposes Except as expressly in this EULA You may not otherwise make copies of the SOFTWARE PRODUCT including the printed accompanying the SOFTWARE DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS Limitations on Reverse Engineering Decompilation and Disassembly You may not reverse engineer decompile or the SOFTWARE PRODUCT except and only to the extent that such activity is expressly permitted by law notwithstanding this limitation You may not make any changes or modifications to the Software without written permission of an officer of DSC You may not remove any proprietary notices marks or labels from the Product You shall institute reasonable measures to ensure compliance with the terms and conditions of this Separation of Components The SOFTWARE PRODUCT is licensed as a single product Its component parts may not be for use on more than one HARDWARE unit Single INTEGRATED PRODUCT If You acquired this SOFTWARE with HARDWARE then the SOFTWARE is licensed with the HARDWARE as a single integrated product In this case the SOFTWARE PRODUCT only be used with the HARDWARE as set forth in this EULA Rental You may not rent lease or lend the SOFTWARE PRO

Related Files