DSC Escort EMS Output PC1616 1832 1864 V4 2

File Preview
File Preview
Click below to download for free

File Data

Name dsc-escort-ems-output-pc1616-1832-1864-v4-2-9305174682.pdf
Type PDF
Size 594.26 KB
Downloads

Text Preview

Thermostat Output Control PC1616 1832 1864 V4.2 Notes SERIES PC1616 1832 1864 V4.2 optional Module Thermostat Internal Temperature Sensor optional Outdoor Temperature Sensor optional application will provide an example for setting the temperature depending on the armed of the panel The Escort will change the temperature to the programmed setting when the is armed in the Stay or Away setting or when disarmed Notes The Application Note assumes that the EMS X00 will be used to control both heating and The user cannot change the temperature Any time the user manually the temperature set point for an Occupancy Setting it will change to the new setting Occupancy Settings Day sun icon and Night moon icon Sections Section 800 Section 803 Section 804 Section 808 Section 809 Panel Section 010 503 PC5208 PGM Output Programming 1 Options 1 Day Setting Output Option 1 Day Setting PGM Output 1 Night Setting Output Option 1 Night Setting PGM Output enter ESCORT programming perform the following on any local touchtone phone on any local touchtone phone Turn the ESCORT ON 8 ESCORT Service Code ESCORT programming The default Service Code is 5580 1 Thermostat 1 Options Escort Section 800 Turn Option 01 ON to enable the thermostat Turn Option 02 ON if an EMS OTS outdoor temperature sensor is connected Turn Option 03 ON if the thermostat will be used to control heating Turn Option 04 ON if the thermostat will be used to control cooling Turn Option 05 ON so the Day Occupancy Setting will always activate by output Turn Option 06 ON so the Night Occupancy Setting will always activate by output Page 23 2 Thermostat 1 Day Occupancy Setting Output Option Escort Section 803 data 01 for output control only The user will always have manual control as well 3 Thermostat 1 Day Occupancy Setting PGM Output Escort Section 804 data 03 The Escort will adjust the temperature to the value programmed for the Day Setting when PGM Output 03 is activated by the panel 4 Thermostat 1 Night Occupancy Setting Output Option Escort Section 808 data 01 for output control only The user will always have manual control as well 5 Thermostat 1 Night Occupancy Setting PGM Output Escort Section 809 data 05 The Escort will adjust the temperature to the value programmed for the Night Setting when PGM Output 05 is activated by the panel 7 PGM Output 03 to 10 Programming Panel Section 010 143 different outputs are needed stay arm away arm and disarm To get an output to activate disarm status we must an output programmed for armed status 010 Program the following 03 data 05 for Status 04 data 18 for Arm 503 Program the following Option 3 OFF will the output instead of activating when the panel is the output will activate when the panel is disarmed When the panel is armed in the setting the panel will activate PGM Output and the Escort will adjust the temperature to the value programmed for the Occupancy Setting When the panel is disarmed the panel will activate Output 03 and the Escort will adjust the temperature to the value for the Day Occupancy Setting Page 24

Related Files