DSC Escort Scheduling PC1616 1832 1864 V4 2
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-escort-scheduling-pc1616-1832-1864-v4-2-1874932506.pdf |
---|---|
Type | |
Size | 594.01 KB |
Downloads |
Text Preview
Thermostat Scheduling Control PC1616 1832 1864 V4.2 Notes SERIES PC1616 1832 1864 V4.2 Module Thermostat Internal Temperature Sensor optional Outdoor Temperature Sensor optional home installation with one thermostat This application will provide an example for setting temperature by schedule The Escort will automatically change the temperature to the setting at 8 00 am and 11 00 pm Notes The Application Note assumes that the EMS X00 will be used to control both heating and The user cannot change the temperature Any time the user manually the temperature set point for an Occupancy Setting it will change to the new setting Occupancy Settings Day sun icon and Night moon icon Sections Section 030 to 032 Schedule 01 Programming Section 033 to 035 Schedule 02 Programming Section 800 Section 801 Section 803 Section 806 Section 808 1 Options 1 Day Setting Schedules 1 Day Setting Output Option 1 Night Setting Schedules 1 Night Setting Output Option enter ESCORT programming perform the following on any local touchtone phone on any local touchtone phone Turn the ESCORT ON 8 ESCORT Service Code ESCORT programming The default Service Code is 5580 Page 25 Program data 0800 in Section 030 8 00 am On Time Program data 9999 in Section 031 no Off Time is required Turn Options 01 through 07 ON in Section 032 to enable all days of the week 1 Schedule 01 Programming Escort Section 030 to 032 of the 16 schedules contain three program items On time Off Time and Day of the Week The new temperature will be set when the schedule is activated On Time so no Off is required Schedule 01 will be used for the Day Occupancy Setting starting at 8 00 am will be programmed as follows 2 Schedule 02 Programming Escort Section 033 to 035 02 will be used for the Night Occupancy Setting starting at 11 00 pm and will be as follows 3 Thermostat 1 Options Escort Section 800 Program data 2300 in Section 033 11 00 pm On Time Program data 9999 in Section 034 no Off Time is required Turn Options 01 through 07 ON in Section 035 to enable all days of the week Turn Option 01 ON to enable the thermostat Turn Option 02 ON if an EMS OTS outdoor temperature sensor is connected Turn Option 03 ON if the thermostat will be used to control heating Turn Option 04 ON if the thermostat will be used to control cooling Turn Option 05 ON so the Day Occupancy Setting will always activate by schedule Turn Option 06 ON so the Night Occupancy Setting will always activate by schedule 4 Thermostat 1 Day Occupancy Setting Schedule Assignment Escort Section Option 01 ON for the Day Occupancy Setting to follow Schedule 01 5 Thermostat 1 Day Occupancy Setting Output Option Escort Section 803 data 02 for schedule control only The user will always have manual control as well 6 Thermostat 1 Night Occupancy Setting Schedule Assignment Escort Section Option 02 ON for the Night Occupancy Setting to follow Schedule 02 7 Thermostat 1 Night Occupancy Setting Output Option Escort Section 808 data 02 for schedule control only The user will always have manual control as well 8 00 am every day the Escort will adjust the temperature to the value for the Day Occupancy Setting and at 11 00 pm the Escort will the temperature to the value programmed for the Night Occupancy Page 26