DSC F2-221-Installation Sheet-UK-English
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-f2-221-installation-sheet-uk-english-5172693480.pdf |
---|---|
Type | |
Size | 892.71 KB |
Downloads |
Text Preview
FEATURES THE DETECTOR MOTION DETECTOR Patented Multi Level Signal Processing PIR Digital temperature compensation Digital microwave signal processing DRO microwave technology for low current and reliable Adjustable microwave detection pattern to match room size MOV transient static protection High RF immunity with SMD construction Exceptional white light immunity Microprocessor low voltage protection Tamper switch Form A alarm contacts Two independent PIR sensors optimized for long and short detections Voltage 9.5 to 14.5 VDC Tolerance 3 VP P at 12 VDC Current 30 mA at 12 VDC Current 30 mA at 12 VDC Contacts Form standard Contact Standard Ratings 100 mA at 24 VDC Contact Series Resistance 10 0.25W max length x max width 60 70 18m 21m Range Adjust 30 to 70 9m to 21m Duration 2 seconds Speed 0.5 ft s to 10 ft s 0.15m s to 3.0m s Mounting Height 7.5 2.3m Alarm LED on off Immunity 30 V m over range 0.01 to 1200 MHz at Terminals 2.4 kV at 1.2 joules Discharge Immunity 25 kV Light 20 000 Lux at the detector Temperature 32 to 122 F 0 to 50 C 5 to 95 RH non condensing Compensation Over entire operating range F2 221 UK is a dual detector employing both microwave and passive infrared PIR motion sensors The sensors are through a microprocessor to provide intelligent motion designed to eliminate single detector false alarms technical features such as the PIR s Multi Level Signal MLSP digital temperature compensation a highly DRO microwave sensor and digital MW signal analysis for a new level of detection sensitivity stability and false immunity PIR and MW systems are each designed as independent high motion detectors When combined the result is a detector unmatched performance detector indicates an alarm when both sensors detect motion 10 seconds of each other The first sensor either the PIR or which detects motion will start the 10 second confirmation during which the other sensor must also detect motion If first sensor detection is not confirmed within 10 seconds the disregards the alarm MW BEAM PATTERNS the detector in a dry indoor location which will force the to walk perpendicular to the beam and allow the beam to adequately cover the area being protected Survey the location and the area being protected for the following problems HEIGHT Force2 is designed to provide optimum coverage when between 2.1m 7 to 2.4m 8 from the floor If the unit is above 2.4m 8 the PIR will have a slightly longer range the zone directly below the unit will be increased If the is mounted below 2.1m 7 the PIR section will have a shorter and the zone directly below the detector will be Optimum dual detector detection occurs when the patterns of the PIR and MW section are matched between PIR and MW coverage patterns could its effectiveness METALLIC SURFACES not aim the detector at reflective surfaces or metallic surfaces could vibrate Reflective surfaces could distort the PIR coverage vibrating metallic surfaces or rotating fans could be seen motion by the MW sensor Metallic surfaces close to the unit may MW sensitivity FLOW Force2 is protected against air flow and airborne However do not locate the detector where it will subject to direct high air flow such as fans hot air vents or open not locate the detector near a source of oil or water vapour as a steaming kettle or cooking area in a kitchen Force2 is resistant to white light but direct sunlight is a high source Do not locate the detector where it will receive sunlight particularly in the morning or evening when the sun low and may shine in through a window CHANGES not aim the detector at objects that change temperature rapidly as heaters or ovens not limit the desired area of protection by placing large objects as plants or filing cabinets so as to obstruct the detector s pattern not aim the detector where pets may trigger either the microwave PIR motion sensors If both sensors are tripped an alarm will THE DETECTOR open the detector pull on the front of the detector while pressing the release at the bottom of the detector with a small screwdriver remove the circuit board and sensor assembly from the detector press gently on the top of the MW detector until the circuit unlocks and slides towards the bottom of the detector replace the circuit board and sensor assembly place the board assembly into the detector back so that the white frame fits into the two slots in the detector back Press on the bottom of the MW detector assembly to slide the board towards the top of the detector The circuit board will snap firmly into place To avoid damage to the detector do not press against of the components on the circuit board when removing and the board Mounting Bracket Mounting Bracket Mounting Bracket Mounting Bracket Mounting Bracket the circuit board removed use a small screwdriver to punch the wiring and mounting knockouts located in the detector Feed the wiring through the wiring knockout and secure the to the wall AND DM W DETECTOR MOUNTING BRACKETS the optional DM W wall mount DM C ceiling mount brackets to difficult placement problems DM W and DM C mount to either wall or ceiling and allow for full and horizontal positioning of motion detector the detector can tilted up or down and rotated 90 to obtain the best position optimal coverage The Force2 has designed to be fully compatible the DM W and DM C brackets your DSC distributor for more NOTE Maximum coverage occurs when the is mounted at the height specified in the mounting and the mounting surface is vertical If this cannot achieved with a mounting bracket then detector coverage be less than specified Mounting Bracket Mounting Bracket Mounting Bracket Mounting Bracket Mounting Bracket the detector is mounted in the desired location connect the as shown below Contacts are shown in the non alarm state with power to the detector shall be insulated with PVC TFE PTFE FEP neoprene or UP application of power the alarm indicator will be illuminated 60 seconds to indicate the unit is warming up During this the alarm relay is held in its normal non alarm state After 60 second warm up period the alarm indicator will go out and unit will respond to motion in the protected area INDICATOR ON OFF JUMPER J1 jumper J1 OFF the alarm indicator will turn on each time the goes into alarm With J1 ON the alarm indicator is disabled ADJUSTMENT detector range is adjustable from about 30 minimum to 70 9m minimum to 21m maximum Rotating the potentiometer clockwise increases the range rotating the counter clockwise decreases the range For performance the range should be adjusted so that it the size of the area to be protected The unit is factory for maximum range is strongly recommended that the range of the detector be to match the size of the protected area To do this first the LED jumper to the OFF position to enable the LED someone walk at the farthest spot from the detector that is still the desired detection area