DSC GS3055-ICF GSM Universal Wireless Commercial Fire Alarm Communicator
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-gs3055-icf-gsm-universal-wireless-commercial-fire-alarm-communicator-8562103974.pdf |
---|---|
Type | |
Size | 794.06 KB |
Downloads |
Text Preview
C O M M U N I C AT I O N S Universal Wireless Commercial Alarm Communicator GS3055 ICF is a GSM universal alarm communicator designed for UL fire installations communications technology in which case any failure the communications path shall be annunciated at the station within 5 minutes of the failure or it can used as part of a multiple communications technologies example in conjunction with a DACT When used as a provision shall be made to monitor the integrity of communication path and failure of any communications shall be annunciated at the supervising station and at protected premises within not more than 24 hours of the Contact ID format low cost communications to an IP receiver Compatible with control panels that communicate using Full event reporting Uses GPRS data channel for high speed reliable 4 on board inputs 4 on board outputs open collector SIM card included Activation and initialization via automated telephone system VRU or web user interface provided CONNECT 24 Compatible with Sur Gard System I II III monitoring UL 864 listed CSFM listed receivers UL listed power supply transformer and Ah rechargeable battery GS3055 ICF connects the alarm control panel to the network and reports alarm signals directly to a station receiver Sur Gard System II System The GS3055 ICF uses the GPRS data channel of the GSM to ensure low cost high speed and reliable alarm and is compatible with control panels that using the Contact ID format GS3055 ICF is compliant with the latest requirements for Methods as per UL864 and NFPA72 2010 It can be used in Fire Monitoring applications as a your DSC distributor 1 888 888 7838 GS3055 ICF has been approved by the California State Marshal CSFM pursuant to Section 13144.1 of the Health and Safety Code Plan rate plans have been negotiated and are through authorized master resellers Contact your station or visit www connect24 com to find a reseller 11 1 2 x 10 x 3 Voltage 120 VAC Draw 300 mA Environment 32 to 120 F 12.8 lbs O M M U N I C AT I O N S it Works Listing GS3055 ICF can be used as either a Sole Communicator as a Backup Communicator When being used as a Sole the GS3055 ICF will replace the phone line on the panel and as soon as it detects that an needs to be transmitted it will send the alarm across GSM network immediately When being used as a backup communicator assesses the connection to the PSTN phone and only in the event of a phone line failure will it send alarm traffic across the GSM network to the monitoring instances where the control panel does not support Contact the GS3055 ICF has inputs pre set to transmit fire alarm supervisory or system trouble signals are transmitted directly without the need of clearinghouse to the IP linecard of the monitoring station Sur Gard System I System II System III Initializing the Unit and initializing the GS3055 ICF can be done using automated telephone activation system VRU Listing GS3055 ICF is UL listed under File S4019 Listing guide as a sole or backup communicator for Commercial Fire installations When used as a sole communicator GS3055 ICF will send its heartbeat once every 97 ensuring that three heartbeats will be received at supervising station within the 300 second window When as a backup communicator the GS3055 ICF will monitor other communication method DACT and send a daily transmission to the supervising station Information Universal Wireless Fire Alarm U S Model Card Included product information specifications and availability subject to without notice Certain product names herein may be trade names and or trademarks of other companies 2010 05