DSC GS3055-ICF - Installation Manual - English

File Preview
File Preview
Click below to download for free

File Data

Name dsc-gs3055-icf-installation-manual-english-5267104983.pdf
Type PDF
Size 1.34 MB
Downloads

Text Preview

GS3055 I CF Alarm Communicator for central station service fire alarm commercial communicator GSM GPRS network signaling devices Manual This manual contains information on limitations regarding product use and and information on the limitations as to liability of the manufacturer of Contents 1 1 Specifications 1 2 Information 2 of Parts 3 of GS3055 I CF 4 CF Connections Descriptions 5 LEDs 6 Modes 7 Simulated Land Line Dialer Mode 7 Activation Mode 8 8 ID Events Description 8 Wiring Diagrams 9 GS3055 I CF is a wireless communicator for UL commercial fire and or burglary applications The CF can send status change events information over the GSM GPRS Network from the Alarm Panel at the protected premises to a supervising station The device is compatible with UL listed receiver Models SG SYSTEM III using SG DRL3 IP line card SG SYSTEM II and SG SYSTEM product is UL listed under requirements of UL864 9th Edition and UL1610 Standards as a Fire Alarm for central station service fire alarm commercial and it can be installed in certified in accordance with the requirements of UL827 Standard and NFPA72 2002 Section 8.5.4 Transmission Technologies NFPA72 2007 Section 8.6.4 Other Transmission Technologies or 2010 Code Section 26.6.3.1 Compatible with listed alarm control panels that have an integrated DACT and support a 4 or 10 digit Complete solution CF Kit includes tamper protection output listed power supply and battery standby ID Communication Format for 24h Telephone line overvoltage protection and monitoring with automatic switch over to the GSM network path when a phone line trouble condition exists GSM network connection and signal strength indicator 4 Input lines and 4 Open collector outputs available for interfacing with the alarm control panel Internet Intranet IP communication over the GSM GPRS network Specifications Voltage 120V 60HZ 0.3A Voltage 12V 7Ah Time 24h NSC plus 5 minutes alarm Battery Sealed rechargeable type replace every 3 5 years Battery Trouble Indication Threshold 11.5VDC Deep Discharge Protection cut off 9.5VDC Current 700mA max 12V 1mA 4 available supervised 12V 50mA 4 open collector available not supervised Resistance 1k ohm max loop resistance between devices connected in series on T1 R1 Frequency 850 1900MHz Dual Band GSM Radio Gain 1.5dB product shall be used only with the supplied antenna Temperature 0 49 32 120 93 RH maximum non condensing Enclosure red with hardwired transformer and high voltage connection box included 290mm x 254mm x 75mm 11 1 2 x 10 x 3 5.8Kg 12.8 lbs including standby battery equipment GS3055 I CF is fixed and shall be installed by Service Persons only Service Person is defined as person having the appropriate technical training and experience necessary to be aware of hazards to which that may be exposed in performing a task and of measures to minimize the risks to that person or other persons to the local rules and regulations It shall be installed and used within an environment that provides the degree max 2 over voltages category II in non hazardous indoor locations only This manual shall be with the Installation Manual of the alarm control panel All instructions specified within that manual must be WARNING The metal shell of the RS232 connector is not earthed Before connecting to this port the metal shell for HAZARDOUS VOLTAGES GS3055 I CF has the capability of communicating alarm signals via the GPRS data network This provides a fast reliable path to central stations equipped with a Sur Gard System III System or SG SYSTEM I receiver By connecting a GS3055 I CF to a control panel standard PSTN interface Contact ID signals are decoded and seamlessly routed through the GPRS network to of the compatible receiver options performance of the GS3055 I CF depends greatly on GSM Network coverage therefore it not be mounted without first performing placement tests to determine the best location reception minimum one green LED is ON Optional antenna kits are available GS3055 I CF requires enrollment with CONNECT 24 to operate Dealer application forms additional information on the CONNECT 24 Voice Response Unit VRU and web user can be found at www connect24 com or at the following telephone numbers 1 888 251 7458 1 888 251 7458 1 888 251 7458 1 888 251 7458 1 888 251 7458 1 888 955 5583 1 888 955 5583 1 888 955 5583 1 888 955 5583 1 888 955 5583 Information Commercial Fire Monitoring Installations Commercial Fire Monitoring Installations Commercial Fire Monitoring Installations Commercial Fire Monitoring Installations Commercial Fire Monitoring Installations GS3055 I CF can be used in the following configurations Standalone communicator single communication technology 5 minute supervision Heartbeat to supervising station every 97 seconds Back up communicator line for a DACT dual communication technology no heartbeat sent Alarm signals must be sent first over the primary communication path DACT and then if this is to have failed over the secondary communication paths Other transmission technologies Primary Compatible Listed control unit land line to central station primary Secondary GS3055 I CF transmission through GSM GPRS network to central station Every 24 hours a check in signal must be sent to the central station over the primary dialer The CF sends a heartbeat test transmission to the supervising station every 24 hours Each communication path shall be monitored for integrity DACT shall have line monitoring and GS3055 ICF shall have cellular connection supervision enabled UL Central Station Commercial Burglary Installations UL Central Station Commercial Burglary Installations UL Central Station Commercial Burglary Installations UL Central Station Commercial Burglary Installations UL Central Station Commercial Burglary Installations GS3055 I CF can be used in the following configurations Standalone communicator single line 200 second supervision heartbeat sent to supervising every 97 seconds Alarm receiver supervision window set to 200 seconds Primary communicator line for a DACT heartbeat sent to supervising station every 97 seconds receiver supervision window set to 200s Back up communicator line for a DACT no heartbeat sent GS3055 I CF is designed to work with the Contact ID communication format as described in SIA Standard Before comple

Related Files