DSC GS4015 - GS4005 - 3G4005 - TL405LE - Installation Manual - R002 - English

File Preview
File Preview
Click below to download for free

Text Preview

GS4015 GS4005 3G4005 TL405LE 2.00 Cellular Ethernet Communicators Guide lights LED screw parked position mounting holes 4 hinge Antenna cable hole 2700 mAh rechargeable battery optional versions with only Wall tamper device Hole for wall tamper device fixing SIM holder PC LINK connector Programming jumpers see of jumpers on 11 USB port versions with housing only Tamper contact Terminal boards Electronic board locator pins JP2 current draw limiter jumper versions with housing see of jumpers on page 11 Battery connector versions with housing only ANTLTE 02 adapter cable Adapter cable nut Integrated antenna versions with housing only Hole for antenna cable on metal bracket Metal bracket ANTLTE 02 multi band antenna with 2 m cable and connector optional Multi band antenna with 2 m cable and MMCX Electronic board mounting holes 4 Ethernet port versions with housing only 1 Identification of parts version with housing Cellular Ethernet Communicators 2 Identification of parts a version with housing b ANTLTE 02 multi band antenna with 2 m cable and SMA optional c kit version specifications 6 specifications 8 of parts 10 of jumpers 11 of indicator lights 12 of terminals 14 15 example 23 DESCRIPTION levels 25 connector functions 26 Monitor 27 events 28 Principles 30 handling 32 as you go balance check 33 Transmission Monitoring PTM 34 outputs 35 Programming 37 app 41 PROGRAMMING 46 49 Settings 52 55 62 Receivers 68 Messages 70 71 Log 72 Update 73 74 and Uploading 76 with EN 50136 2 2013 80 with the USB key 82 86 http dsc com pdf 2001003 T4 S2 I3 for digital messages 50131 10 Security Grading 2 50130 5 Class I T4 S2 I3 for digital messages 50131 10 Security Grading 2 50130 5 Class I Tyco Safety Products Canada Ltd declares that the radio equipment type GS4015 GS4005 GS4005 K 3G4005 EU 3G4005 K EU and TL405LE instructions apply to communicators with firmware revision 2.00 and above full text of the EU declaration of conformity is available at the following internet address GS4015 http dsc com pdf 1711001 GS4005 http dsc com GS4005 K http dsc com pdf 1603005 3G4005 EU http dsc com pdf 1603002 3G4005 K EU http dsc com pdf 1603003 TL450LE are in compliance with Directive 2014 53 EU GS4005 GS4005 K 3G4005 EU and 3G4005 K EU product models have been certified by IMQ A to be compliant with standards 50136 1 2012 and EN 50136 2 2013 for alarm transmission system performance SP2 D2 M2 T2 S0 I0 for vocal text alarm messages and SP4 D3 50136 1 2012 and EN 50136 2 2013 for alarm transmission system performance SP2 D2 M2 T2 S0 I0 for vocal text alarm messages and DP3 D3 TL405LE EU product model has been certified by IMQ A to be compliant with standards To ensure conformity with the T031 standard the Communicator must be connected to the panel with terminals LI and the following events and messages must be set INTRUSION ALARM TAMPER ALARM MAIN POWER FAILURE BATTERY FAILURE HOLD UP ARMING DISARMING ZONE AND ISOLATED ZONE communicator is certified IMQ SECURITY SYSTEMS if powered by the panel and without backup battery of these systems must be carried out strictly in accordance with the instructions described in this manual and in compliance with the local laws bylaws in force The above mentioned devices have been designed and made to the highest standards of quality and performance The manufacturer that the installed system should be completely tested at least once a month Digital Security Controls shall not be responsible for damage arising improper installation or maintenance by unauthorized personnel Digital Security Controls reserves the right to change the technical specifications of Security Controls recommends that customers dispose of their used equipment panels detectors sirens and other devices in an environmentally manner Potential methods include reuse of parts or whole products and recycling of products components and or materials For specific information ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE DIRECTIVE the European Union this label indicates that this product should NOT be disposed of with household waste It should be deposited at an facility to enable recovery and recycling For specific information see www dsc com product without prior notice INFORMATION www dsc com Cellular Ethernet Communicators devices made by GS4015 GS4005 3G4005 and TL405LE series are cellular communicators that provide a backup PSTN line are able to transmit vocal GS4005 3G4005 and TL405LE only and SMS alarm messages to the end user and digital mes to supported Sur Gard System receivers By means of the ConnectAlarm app running on Android and iOS mobile devic you can manage the communicator and the control panel wired to it and view the communicator and control panel events TL405LE model has an Ethernet interface that may be used as main communication channel or for cellular communication backup dual path for digital message transmission to supported Sur Gard System receivers The Ethernet interface en an alternative and faster way to program the communicator The following versions are available GS4015 communicator board with 2G module in plastic housing GS4005 communicator board with 2G module in plastic housing GS4005 K kit including communicator board with 2G module antenna with 2 m cable adapter and metal bracket 3G4005 EU communicator board with 3G module in plastic housing for the Europe Union market 3G4005 K EU kit including communicator board with 3G module antenna with 2 m cable adapter and metal bracket for the TL405LE EU dual path communicator board with LTE module and Ethernet interface in plastic housing for the Europe TL405LE LAT dual path communicator board with LTE module and Ethernet interface in plastic housing for the Latam TL405LE ANZ dual path communicator board with LTE module and Ethernet interface in plastic housing for the Australian Union market market New Zealand markets special installation requirements a remote outdoors antenna ANTLTE 10 with 10 m cable is available information in this manual is common to all versions The term refers to functions shared by all versions In relating to specific models is highlighted with reference to the respective code Some of the topics found in this manual may not be relevant to your version refer to specifications on page 6 to see features of your version References to Ethernet apply to TL405LE only manual provides instructions for programming and using the communicator instructions the safety information before you install the equipment Important This equipment must be installed by a skilled person only A skilled person is an installer with appropriate training The installer must be aware of potential hazard

Related Files