DSC Hardwired Zones PC1616 1832 1864 V4 2

File Preview
File Preview
Click below to download for free

File Data

Name dsc-hardwired-zones-pc1616-1832-1864-v4-2-1956034827.pdf
Type PDF
Size 595.62 KB
Downloads

Text Preview

Notes Hardwired Zones PC1616 1832 1864 V4.2 SERIES PC1616 1832 1864 V4.2 zones is a three step process the zone definitions the zone attributes Optional additional zones to the system Definitions Attribues Optional Zone Assignent Zones 1 to 64 001 Zones 1 to 16 002 Zones 17 to 32 003 Zones 33 to 48 004 Zones 49 to 64 Sections 001 004 101 164 202 265 1 Programming Zone Definitions must be defined before they will operate On the POWER SERIES 39 different zone definitions are Enter the correct section and program the 2 digit number corresponding to the required zone 2 Programming Zone Attributes Optional attributes are used to customize the operation of each zone There are 64 sections available Section for zone 1 to Section 164 for zone 64 Each Section has 9 toggle options Turn the appropriate ON or OFF depending on the required operation 1 Zone audible silent 2 Steady bell output pulsing bell output 3 Door chime enable disable 4 Manual bypass enable disable 5 Force arm enable disable 6 Swinger shutdown enable disable 7 Transmission delay enable disable 8 Wireless zone enable disable 9 Cross Zone enable disable 14 NC Zone Wiring loop 15 EOL Zone Wiring loop 16 DEOL Zone Wiring loop Options 14 15 16 apply to first 8 zones only If more than one of these options are enabled lowest numbered option is enabled E g If Option 14 and option 15 are enabled then zones are configured as normally closed loops The zone attributes for the zone will reset to the default settings if the zone definition is A chart of the default settings for each zone definition is available in the Worksheets Page 27 3 Partition Zone Assignment will not function until they are enabled Enable all zones being used by turning ON the appropriate in Section 202 to 265 1 zones 1 to 64 enable disable 2 zones 1 to 64 enable disable 3 zones 1 to 64 enable disable 4 zones 1 to 64 enable disable 5 zones 1 to 64 enable disable 6 zones 1 to 64 enable disable 7 zones 1 to 64 enable disable 8 zones 1 to 64 enable disable 202 209 210 217 218 225 226 233 234 241 242 249 250 257 258 265 zones are assigned to additional partitions ensure the partitions are enabled in Section Tips The zone attributes for the zone will reset to the default settings if the zone definition is changed this reason always program zone definitions before programming zone attributes Only zones 1 to 8 are enabled at default If additional zones are being used they must be enabled they will function Test all programming is complete violate each zone and ensure each is displayed on the keypad Arm the in both the Stay and Away mode to ensure all zones are functioning properly Page 28

Related Files