DSC HS-FDR - Installation Manual - English - Concourse Flush Mount Door Enforcement

File Preview
File Preview
Click below to download for free

Text Preview

FCC COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Controls Ltd could void your to use this equipment equipment has been tested and found to comply with the limits for a Class B digital device pursuant to 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer in a residential installation This equipment generates uses and can radiate radio frequency energy and not installed and used in accordance with the instructions may cause harmful interference to radio commu However there is no guarantee that interference will not occur in a particular installation If this does cause harmful interference to radio or television reception which can be determined by turn the equipment off and on the user is encouraged to try to correct the interference by one or more of the fol measures the receiving antenna the separation between the equipment and receiver the equipment into an outlet on a circuit different from that to which the receiver is connected the dealer or an experienced radio television technician for help user may find the following booklet prepared by the FCC useful to Identify and Resolve Radio Tele Interference Problems This booklet is available from the U S Government Printing Office Washington 20402 Stock 004 000 00345 4 Security Controls Ltd warrants that for a period of 12 months from the date of purchase the product shall be free defects in materials and workmanship under normal use and that in fulfillment of any breach of such warranty Digital Controls Ltd shall at its option repair or replace the defective equipment upon return of the equipment to its depot This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or or damage due to causes beyond the control of Digital Security Controls Ltd such as lightning excessive volt mechanical shock water damage or damage arising out of abuse alteration or improper application of the equip foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd Digital Controls Ltd neither assumes responsibility nor authorizes any other person purporting to act on its behalf to or to change this warranty nor to assume for it any other warranty or liability concerning this product no event shall Digital Security Controls Ltd be liable for any direct indirect or consequential damages loss of antici profits loss of time or any other losses incurred by the buyer in connection with the purchase installation or opera or failure of this product Digital Security Controls Ltd recommends that the entire system be completely tested on a regular basis despite frequent testing and due to but not limited to criminal tampering or electrical disruption it is possible this product to fail to perform as expected INFORMATION Changes or modifications not expressly approved by Digital Security Controls Ltd void the user authority to operate this equipment Digital Security Controls Ltd Canada Support 1 800 387 3630 www dsc com Printed in Canada HS PDR HS LDR Cabinet Doors Instructions HS FDR HS PDR and HS LDR series of cabinet doors are intended for use the HS CAB series of Cabinets including HS CAB1000 HS CAB3000 and Series 16 gauge steel plate doors that secure to the cabinet with screws Series bronze smoked plastic versions of the HS FDR series provision has been made on the HS PDR series for the addition of a lock Series steel plate doors that secure to the cabinet by inserting the tabs into the slots provided at the bottom of the cabinet and locking in of Package 1 Concourse Label for insertion into Label panel provided 1 Lock HS LDR series only 4 Mounting Screws HS FDR1000 and HS PDR1000 only 6 Mounting Screws HS FDR3000 4000 and HS PDR3000 4000 only 16.25in 414mm Height 30.5in 775mm Height 44 in 1118mm Series Metal Door Width 16.25in 414mm Width 16.25in 414mm Width 16.25in 414mm Series Door 16.25in 414mm Height 30.5in 775mm Height 44 in 1118mm 16.25in 414mm Width 16.25in 414mm Width 16.25in 414mm Series Door 15.3in 389m 15.3 389mm 29.6in 752mm Height 43.9 in 1115mm 15.3 389mm Width 15.3 389mm Series Doors Installation Remove the knock outs 1 for the tabs located at the bottom of the cabinet before mounting cabinet the lockset into the opening 2 provided at the top of the door Affix the Concourse label to the front of the door in the area provided Slide the door tabs 3 at the bottom of the door into the slots in the bottom the cabinet Push the top of the door towards the cabinet until fully closed the key into the lock and turn clockwise to lock the cabinet HS PDR Series Metal and Plastic doors Installation Affix the Concourse label to the front of the door in the area 1 provided two 1 panhead philips machine screws supplied in the top two 2 of the cabinet Allow min clearance for doors Position the two keyholes of the door 3 over the screws and hang the door the two screws remaining screws Securely fasten all screws 4 2 HS FDR PDR Installation 2 1 pan head screws at the top of the cabinet all the way in Allow clearance min for the door 1 HS LDR Installation door keyholes on the cabinet screws Lock the remaining screws tighten the top screws Label on front of door PDR Series plastic doors do not have drilled keyways to facilitate mounting cabinets The door must be held in place when installing the first 2 screws tightening of screws on PDR Series plastic doors may result in damage to door PDR Series plastic doors are not approved for UL ULC installations door tabs into slots bottom of panel door knock outs by forcing upwards inside with a head screw driver

Related Files