DSC HS-VT1640 - Installation Manual - English - Concourse 1x6 Analog Bridged Telecom Expansion Module With 1x4 Passive Video Splitter
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-hs-vt1640-installation-manual-english-concourse-1x6-analog-bridged-telecom-expansion-module-with-1x4-passive-video-splitter-3984762150.pdf |
---|---|
Type | |
Size | 758.49 KB |
Downloads |
Text Preview
FCC COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Controls Ltd could void your to use this equipment equipment has been tested and found to comply with the limits for a Class B digital device pursuant to 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer in a residential installation This equipment generates uses and can radiate radio frequency energy and not installed and used in accordance with the instructions may cause harmful interference to radio commu However there is no guarantee that interference will not occur in a particular installation If this does cause harmful interference to radio or television reception which can be determined by turn the equipment off and on the user is encouraged to try to correct the interference by one or more of the fol measures the receiving antenna the separation between the equipment and receiver the equipment into an outlet on a circuit different from that to which the receiver is connected the dealer or an experienced radio television technician for help user may find the following booklet prepared by the FCC useful to Identify and Resolve Radio Tele Interference Problems This booklet is available from the U S Government Printing Office Washington 20402 Stock 004 000 00345 4 Security Controls Ltd warrants that for a period of 12 months from the date of purchase the product shall be free defects in materials and workmanship under normal use and that in fulfillment of any breach of such warranty Digital Controls Ltd shall at its option repair or replace the defective equipment upon return of the equipment to its depot This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or or damage due to causes beyond the control of Digital Security Controls Ltd such as lightning excessive volt mechanical shock water damage or damage arising out of abuse alteration or improper application of the equip foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd Digital Controls Ltd neither assumes nor authorizes any other person purporting to act on its behalf to modify or to this warranty nor to assume for it any other warranty or liability concerning this product no event shall Digital Security Controls Ltd be liable for any direct indirect or consequential damages loss of antici profits loss of time or any other losses incurred by the buyer in connection with the purchase installation or opera or failure of this product Digital Security Controls Ltd recommends that the entire system be completely tested on a regular basis despite frequent testing and due to but not limited to criminal tampering or electrical disruption it is possible this product to fail to perform as expected INFORMATION Changes or modifications not expressly approved by Digital Security Controls Ltd void the user authority to operate this equipment Module Instructions HS VT1640 combines a 1 x 6 telecom module with a 1 x 4 video splitter on the same mounting for use with the DSC Concourse Home Wiring Systems solution The telecom section features 8 position 110 IDC connector for up to 4 incoming lines six 8 position 110 IDC connectors for outlets to the system and an RJ31X jack as a security system connection The video sec features one ANT CATV input and four outputs for multi room video signal distribution All connectors use style fittings position 110 IDC connector for up to 4 incoming lines position 110 IDC connectors for connecting outlets to the system jack for security system connection input output for multi room video signal distribution splitter connectors use style fittings Splitter module 5MHz 1GHz Loss 6.5 dB MAX P to P 25 dB MIN Loss 18 dB MAX 75 Ohm Input Lines 4 Wiring Standard T568A Connections 6 Interfaces RJ31X Line 1 Connection 110 Style IDC Connection 110 Style IDC Out Connection None Home Systems is a division of Digital Security Controls Ltd Digital Security Controls Ltd Canada www dsc com in Canada 29005811 R001 of Package x 4 Video Splitter on a mounting plate x 6 Telecom Distribution Module standoffs Instructions the standoffs 7 into the mounting plate to match the hole positions on the telecom dis module Refer to figure 1 the Telecom Distribution Module over the stand offs and snap in place a suitable mounting location for the HS VT1640 Telecom Video module inside the cabi The upper left corner of the cabinet is recommended the two mounting tabs with the slots in the wire raceway and insert the module the locating pin with the hole in the cabinet and snap module in place Instructions Service Cables the incoming telephone service cable s into the cabinet through the raceway to the HS module Allow sufficient length at both ends of the cable run to avoid stress to cables connectors and to permit proper termination and trim out the incoming telecom service cable s at the telephone line in connector labeled IDC using a 110 punchdown tool Line 1 terminates at L1 Line 2 at L2 Line 2 at L3 and Line 4 at See Figure 1 the incoming video service cable into the cabinet through the raceway to the HS module Allow sufficient length at both ends of the cable run to avoid stress to cables connectors and to permit proper termination and trim out a standard style connector to the incoming service cable Connect the terminated service cable at the terminal marked See Figure 1 all connections to confirm proper installation and termination Cables CAT5 cable to each desired telecom location and route the cables into the cabinet the raceway to the HS VT1640 module Allow sufficient length at both ends of the run to avoid stress to cables and connectors and to permit proper termination and trim Label each cable at both ends for easy identification each CAT5 drop at the desired location using an RJ45 keystone jack wired to TIA standard observing proper CAT5 wiring practices Trim out using the appropriate wall If using a multiple wall outlet identify the telecom jack accordingly each CAT5 drop at the HS VT1640 module IDC termination blocks labeled IDC 2 IDC 7 using a 110 punchdown tool and observing proper CAT5 wiring practices See 1 RG6 coax cable to each desired location and route the cables into the cabinet through the to the HS VT1640 module Allow sufficient length at both ends of the cable run to stress to cables and connectors and to permit proper termination and trim out Label cable at both ends for easier identification each RG6 drop at the desired location using an style connector Attach the con to an style jack and trim out using the appropriate wall plate If using a multiple outlet identify the jack accordingly each RG6 drop at the HS VT1640 module using a standard style connector the terminated drops to the terminals marked or any unused output terminals with a 75 terminator all connections to confirm proper installation and termination