DSC HS2016-HS2032-HS2064-HS2128 - Installation Guide - v1 0 - ENG - R001

File Preview
File Preview
Click below to download for free

Text Preview

Alarm Controller v1.0 Installation Guide installation guide provides the basic wiring programming and troubleshooting information required to install the PowerSeries Neo alarm controller Use this guide in conjunction the PowerSeries Neo Reference Manual available online from the DSC website at www dsc com Available models HS2016 HS2032 HS2064 HS2128 Setup the battery and power up the system The must be connected Key the installation including all alarm detection zone expanders keypads and other modules on a location for the alarm panel and it to the wall using suitable mounting all wiring including modules zones telephone line connections and ground Record module serial numbers on 13 Wire the keypad to the Corbus power the alarm panel then press any button on the Wire the HSM2Host to the Corbus then up the alarm panel and a wireless keypad any button on the keypad to enroll it The is then enrolled on the alarm panel enroll an RF keypad Code 902 subsection 000 Press to begin auto enrollment slots are automatically assigned Use keys to view slots Change slot by typing a number Code 804 subsection 000 An HSM2HOST or RF keypad must be first programming code Zone Type Zone Attribute Partition 1 Timers Entry Delay 1 Entry Delay 2 Exit Delay Phone 1 System Account Code the panel completely to ensure that all and functions operate as programmed 901 Walk Test 904 000 Wireless Placement Test Devices this document x in the model number represents the operating frequency of the device follows 9 912 919 MHz 8 868MHz 4 433MHz Only models operating in the band 912 919 MHz are UL ULC listed where indicated Only approved devices are to be used with UL ULC listed systems 1 1 Compatible Devices keypads keypads with 2 way wireless module keypads wireless integration module expander expander supply high current output expander communicator smoke detectors A B or C ULC listed models UL listed models European and Australian models smoke detectors A B or C ULC listed models UL listed models European and Australian models detectors Devices UL UL Devices PG smoke detectors PG CO detector PG PIR motion detectors PG glass break detector PG shock detector PG flood detector PG temperature detector indoor use PGx905UL temperature probe requires PGx905 PGTEMP PROBE PG keys PG sirens PG repeater PG door window contacts I II III IV Station Receivers PC4050CR ULC Fire Monitoring PC4050CAR UL Commercial Burg Commercial Burg enclosures are available to suit a variety of system configurations This manual contains information on limitations regarding product use and function and information on the as to liability of the manufacturer The entire manual should be carefully read o w e r S e r i e s N e o I n s t a l l a t i o n G u i d e Descriptions following terminals are available on the PowerSeries Neo alarm controller Instructions for Service Persons When using equipment connected to the telephone network always follow the safety instructions provided with this product Save these instructions for future ref Inform the end user of the safety precautions that must be observed when operat this equipment Installing The Equipment Ensure package includes the following and user manuals including the SAFETY INSTRUCTIONS and SAVE these instructions ALL WARNINGS AND INSTRUCTIONS specified in this document and or the equipment alarm controller supply direct plug in transformer ULC Fire Monitoring A Suitable Location For The Alarm Controller the following list as a guide to find a suitable location to install this equipment Locate near a telephone socket and power outlet Select a location free from vibration and shock Place alarm controller on a flat stable surface and follow the installation instructions NOT locate this product where people may walk on the secondary circuit cable s NOT connect alarm controller to electrical the same circuit as large appliances NOT select a location that exposes your alarm controller to direct sunlight excessive moisture vapors chemicals or dust not install this equipment near water e g bath tub kitchen laundry sink wet base near a swimming pool NOT install this equipment and accessories in areas where risk of explosion exists NOT connect this equipment to electrical outlets controlled by wall switches or auto timers interference sources installing equipment near heaters air conditioners ventilators and refrigerators locating equipment close to or on top of large metal objects e g wall studs Precautions Required During Installation Never install this equipment and or telephone wiring during a lightning storm Never touch uninsulated telephone wires or terminals unless the telephone line has disconnected at the network interface Position cables so that accidents can not occur Connected cables must not be subject to mechanical strain Use only the power supply provided with this equipment Use of unauthorized power may cause damage For direct plug in versions use the transformer supplied with the device THIS EQUIPMENT HAS NO MAINS ON OFF SWITCH THE PLUG OF DIRECT PLUG IN POWER SUPPLY IS INTENDED TO SERVE AS THE DIS DEVICE IF THE EQUIPMENT MUST BE QUICKLY DISCON IT IS IMPERATIVE THAT ACCESS TO THE MAINS PLUG AND MAINS SOCKET OUTLET IS NEVER OBSTRUCTED NOTE alarm system must be installed and used within an environment that provides the pol degree max 2 and over voltages category II NON HAZARDOUS LOCATIONS only The equipment is direct plug in external transformer and is designed to be serviced and or repaired by service personnel only service person is defined as individual having the appropriate technical training and experience to recognize hazards with the installation and operation of this equipment and of measures to mini the risks to themselves and others This equipment contains no user serviceable The wiring cables used for installation of the alarm system and accessories must be with PVC TFE PTFE FEP Neoprene or Polyamide The equipment enclosure must be secured to the building structure before operation Internal wiring must be routed in a manner that prevents Excessive strain or loosening of wire on terminal connections or damage of conductor Disposal of used batteries must be made in accordance with local waste recovery and regulations Before servicing disconnect the power and telephone connection Do not route any wiring over circuit boards The installer must ensure that a readily accessible disconnect device is incorporated into building for permanently connected installations power supply must be Class II fail safe with double or reinforced insulation between primary and secondary circuit enclosure and be an approved type acceptable to the authorities All national wiring rules must be observed the Enclosure the panel in a dry area preferably near an unswitched AC power source and the incom telephone line Complete all wiring before applying AC or connecting the battery BAT AUX BELL to PGM4 to Z8

Related Files