DSC HS2016-HS2032-HS2064-HS2128 - V1 35 - Installation Guide - English
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-hs2016-hs2032-hs2064-hs2128-v1-35-installation-guide-english-7260148593.pdf |
---|---|
Type | |
Size | 1.42 MB |
Downloads |
Text Preview
To download the full installation manual and register your product please visit or scan the QR code to the right this guide in conjunction with the PowerSeries Neo Reference Manual available online from the DSC website Neo Alarm Control Installation Guide Setup Plan Mount Wire Power Enroll Enroll Enroll the installation including all alarm detection devices expanders keypads and other required modules on a location for the alarm panel and secure it to the using suitable mounting hardware all wiring including modules zones bells sirens line connections and ground connections Record serial numbers on page 16 the battery and power up the system The battery be connected Wire the keypad to the Corbus power up the panel then press any button on the keypad Wireless the HSM2Host to the Corbus then power up the alarm and a wireless keypad Press any button on the keypad to it The HSM2Host is then enrolled on the alarm panel enroll an RF keypad Code 902 subsection 000 Press to auto enrollment Module slots are automatically Use scroll keys to view slots Change slot by typing a number Code 804 subsection 000 Note An or RF keypad must be enrolled first Program Basic programming 8 installer code 001 002 Zone Attribute 005 001 Partition 1 Timers Entry 1 Entry Delay 2 Exit Delay 301 001 Phone 1 System Account Code the panel completely to ensure that all features and operate as programmed 901 Walk Test 904 Wireless Placement Test Test Devices this document x in the model number represents the operating of the device as follows 9 912 919 MHz 8 868MHz 4 Only models operating in the band 912 919 MHz are UL ULC listed indicated Only UL approved devices are to be used with UL ULC systems 1 1 Compatible Devices keypads communicator Devices smoke detectors A B or C ULC listed models UL listed models European and Australian models smoke detectors A B or C ULC listed models UL listed models European and Australian models detectors Devices smoke detectors smoke and heat detector CO detector PIR motion detectors PIR camera motion detector curtain motion detector dual tech motion detector mirror motion detector outdoor motion detector glass break detector shock detector flood detector temperature detector indoor use temperature probe requires PGx905 flat PIR recessed Contact ceiling mount detector with Smart Presence Short Range ceiling mount detector with Smart Presence Long Range outdoor contact outdoor curtain PIR keys panic key 2 button key sirens keypads with 2 way wireless module keypads Keypad wireless integration module expander expander supply high current output expander PGx916 PGx913 PGx922 PGx975 repeater door window contacts door window contact w AUX Station Receivers I II III IV 5 PC4050CR PC4050CAR CMC 1 PC4051C Other enclosures are available to suit a variety system configurations This manual contains information on limitations regarding product use and function and information on the as to liability of the manufacturer The entire manual should be carefully read Neo Installation Guide Avoid locating equipment close to or on top of large metal objects e g wall Instructions for Service Personnel using equipment connected to the telephone network always follow the safety instructions provided with this product Inform the end user of the precautions that must be observed when operating this equipment Installing The Equipment your package includes the following items HS2016 4 HS2016 2032 2064 2128 alarm controller Power Supply direct plug in and user guides including the safety instructions A Suitable Location For The Alarm Controller to the following list to find a suitable location to install this equipment Locate near a telephone socket and power outlet Select a location free from vibration and shock Place alarm controller on a flat stable surface and follow the installation Do not locate the equipment where people may walk on the secondary circuit Do not connect alarm controller to the same electrical circuit as large appli Do not select a location that exposes your alarm controller to direct sunlight heat moisture vapors chemicals or dust Do not install this equipment near water e g bath tub kitchen laundry wet basement near a swimming pool Do not install this equipment and accessories in areas where risk of explo Do not connect this equipment to electrical outlets controlled by wall or automatic timers Avoid interference sources Avoid installing equipment near heaters air conditioners ventilators and exists Locating Detectors and Escape Plan on page 17 for information on locating and CO detectors Precautions Required During Installation Never install this equipment and or telephone wiring during a lightning Never touch uninsulated telephone wires or terminals unless the telephone has been disconnected at the network interface Position cables so that accidents can not occur Connected cables must not be to excessive mechanical strain Use only the power supply provided with this equipment Use of unau power supplies may cause damage For direct plug in versions use the power supply provided with the device This equipment has no mains on off switch The plug of the direct power supply is intended to serve as the disconnecting device if the must be quickly disconnected It is imperative that access to the mains and associated mains socket outlet is never obstructed NOTES This equipment is stationary fixed with a direct plug in external transformer a permanently connected internal transformer dependent on the region It be installed by Service Persons only Service Person is defined as a per having the appropriate technical training and experience necessary to be of hazards to which that person may be exposed in performing a task of measures to minimize the risks to that person or other persons It be installed and used within an environment that provides the pollution max 2 over voltages category II in non hazardous indoor locations This equipment has no mains on off switch if the equipment must be quickly the plug of the direct plug in power supply is intended to serve the disconnecting device It is imperative that access to the mains plug and mains socket outlet is never obstructed For permanently connected versions the fuse in the power connector serves the disconnecting device The disconnect device will only remove the power and will not disconnect battery power The installer is respons to ensure that a readily accessible mains disconnect device is incor in the building for permanently connected installations There are no end user replaceable parts replaceable within this equipment Before servicing disconnect the mains power battery and telephone con The equipment enclosure must be secured to the building structure before All national wiring rules must be observed The wiring cables used for installation of the alarm system and accessor shall be insulated with PVC TFE PTFE FEP Neoprene or Polyamide Do not route any wiring over circuit boards Ensure that cables are positioned so that accidents cannot occur Internal wiring must be routed in a manner that prevents Excessive strain or loosening of wire on terminal connections Damage of conductor or insulation Disposal of used batteries must be made in accordance with local waste and recycling regulations Use authorized accessories only with this equipment Do not place any object