DSC Install Manual PK5500 v1 3 - En-Ch
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-install-manual-pk5500-v1-3-en-ch-0794531826.pdf |
---|---|
Type | |
Size | 3.17 MB |
Downloads |
Text Preview
PK5500 v1.3 Instructions Please refer to the System Installation Manual for information on limitations regarding product use and func and information on the limitations as to liability of the manufacturer These instructions shall be used in conjunction with the system Installation Manual of the Control Panel with this equipment is intended to be used PK5500 keypad can be used on security systems with up to 64 These keypads are compatible with the latest version of the foll DSC security systems Temperature range 10 to 55 14 to 131 Humidity MAX 93 R H non condensing Plastic enclosure protection degree IP30 IK04 Voltage rating 12VDC nominal Connects to control panel via 4 wire Keybus 1 keypad zone input PGM output PK5500 Current Draw 50mA standby 125mA maximum Wall mount tamper 5 programmable function keys Ready Green LED Armed Red LED Trouble Yellow LED A C Green LED Low temperature sensor Alarm 6 43 9 48 Zone not to be programmed as Fire type or 24h type Power keypad package includes the following parts Power keypad mounting screws end of line resistors the keypad where it is accessible to designated points of entry exit Once you have selected a dry and secure location perform following steps to mount the keypad Keypad Insert a flat head screwdriver into the provided slot first of two Move screwdriver toward the back plastic and lift as in the following inner door labels tamper switch Instructions This will unhook one side of the front plastic Repeat step 1 and 2 on the second provided slot to disconnect front plastic and allow access for wiring and Wire Keypad Out Slot Out Out engage to Snap Secure Keypad to wall using mounting holes Use all 4 screws provided mounting on a single gang box Place keypad into hooks on the backplate and swing down to engage Run wire through wiring slot or knockouts Connect Keybus and PGM Zone to keypad Place tamper switch into tamper hole on backplate Remove keypad from hooks Place keypad into backplate ensure the wire pushed back into the wall as much as possible Route the wire inside keypad ensuring high components are avoided Snap the front assem closed ensuring there is no pressure to the keypad from the wire If any tension found between the front keypad assembly wiring please open the keypad reroute the wire and close Repeat these steps until the keypad is closed properly Before wiring the unit ensure that all power AC transformer and battery disconnected from the control panel Connect the four Keybus wires from control panel red black yellow green to the keypad terminals to diagram zone or output If programmed as an input you can a device such as a door to the terminal of the This eliminates the need to wires back to the control panel for device To connect the zone run one wire from the device to the and the other wire from the device to the B black terminal For devices run the red wire to the R positive terminal and the wire to the B negative terminal When using end of line supervi connect the zone according to one of the configurations outlined in system Installation Manual If the P Z terminal is programmed as an output the output follows the programmed in Section 080 A small relay buzzer or other DC device may be connected between the positive supply voltage the P Z terminal maximum load is 50mA Power all wiring is complete and the equipment is secured to the building with at least two screws apply power to the control panel Connect the battery leads to the battery Connect the AC transformer more information on control panel power specifications see the control Installation Manual Option keypad 4 the Keypad are several programming available for the key These are described below to programming the rest of the system When you are in the keypad sections the keypad will display which options are turned on the bottom of the display To turn an option on or off press the corresponding to the option on the number pad The numbers of options that are currently turned ON will be displayed For example if 1 and 4 are on the display will look like diagram shown on the keypad displays information on programming the rest of your security system please to your system Installation Manual LCD Labels LCD programming is done per keypad If more than one LCD keypad is on the system labels programmed at one keypad can be broadcast all other LCD keypads Perform the following procedure in order to labels 1 Program one LCD keypad completely 2 Make sure all LCD keypads are connected to the Keybus 3 Enter keypad programming by pressing cid 2 8 Installer then enter section 998 at the keypad that was programmed keypad will now broadcast all the information programmed to all the LCD keypads on the system 4 When the keypad is finished press the key to exit LCD Label broadcast from this keypad is only compati with PC1616 1832 1864 control panels and other keypads Programming the keys for 2 seconds to enter language programming to the desired language and Press cid 2 to select If section 077 option 4 is OFF language programming only be performed while in installers programming the Keypad keypad will need to be assigned to a partition and slot if supervision or zones are being used Keypad assignments and keypad option must be done at each keypad individually 1st digit of keypad assignment is used to determine partition assign 1 to 8 If partitioning is not used enter 1 For Global Keypads 0 2nd digit of keypad assignment is used to determine slot assignment keypad supervision Each keypad will be assigned a different slot num from 1 to 8 PK5500 LCD keypads come defaulted in slot 8 If multi LCD keypads are used one LCD keypad must remain in slot 8 the following at each keypad installed on the system Enter Installer Programming by pressing cid 2 8 Installer Code Press 000 for Keypad Programming Press 0 for Partition and Slot Assignment Enter the 1st digit 0 to 8 for partition assignment Enter the 2nd digit 1 to 8 for slot assignment supervision Press the key twice to exit programming After assigning all keypads perform a supervisory reset by entering Code 902 and wait for 60 seconds Press the key to exit programming Labels Enter keypad programming by pressing cid 2 8 Installer Code cid 2 the 3 digit section number for the label to be programmed Use the arrow keys to move the underline bar underneath the to be changed Press the number keys 1 to 9 corresponding to the letter you require first time you press the number the first letter will appear Pressing number key again will display the next letter etc To select lower case letters press scroll to case press again to select A B C 1 4 J K L 4 7 S T U 7 0 Space D E F 2