DSC Install manual - SCW9055 57 - India - Eng - V1 1
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-install-manual-scw9055-57-india-eng-v1-1-4671308925.pdf |
---|---|
Type | |
Size | 3.41 MB |
Downloads |
Text Preview
Self Contained Wireless Alarm System This manual contains information on limitations regarding product use and function information on the limitations as to liability of the manufacturer The entire manual should carefully read India Installation Guide of Contents Introduction 1 SCW9055 57 Model Differences 1 Compatible Wireless Devices 1 Product Specifications 2 Controls Indicators 3 Data Entry 3 Installation 5 Mounting 5 Wiring 6 Wireless Device Setup 7 Alternate Communicator Module Setup Initialization 9 Operation 10 Operating Modes 10 Language Selection 10 Commands 10 Function Keys 13 System Removal Prevention 13 Programming 14 Template Programming 14 DLS Programming 17 Installer Programming 17 Advanced Programming 18 How to Program 18 Index to Programming Worksheets and Descriptions 19 Programming Worksheets 20 Programming Descriptions 42 Testing and Troubleshooting 68 A Reporting Code Formats 71 B 2 Way Audio Verification SCW9057 only 75 C Communicator Format Options 76 INSTRUCTIONS FOR SERVICE PERSONS When using equipment connected to the TELEPHONE NETWORK always follow basic safety instructions Refer to the INTRUCTIONS provided with this product save them for future reference Instruct the end user regarding the safety pre that must be observed when operating this equipment Installing The Equipment your package includes the following items and User Manuals including the SAFETY INSTRUCTIONS and SAVE these instructions All WARNINGS AND INSTRUCTIONS specified within this document and or on the equipment alarm controller Supply direct plug in Mounting hardware A Suitable Location For The Alarm Controller the following list as a guide for finding a suitable location to install this equipment near a telephone socket and power outlet a place free from vibration and shocks the alarm controller on a flat stable surface and follow the installation Instructions NOT install this product where people may walk on the secondary circuit cable s NOT connect the alarm controller to electrical outlets on the same circuit as large appliances NOT select a location that exposes your alarm controller to direct sunlight excessive heat moisture vapors chemicals or dust NOT install this equipment near water e g bath tub sink wet basement near a swimming pool NOT install this equipment and its accessories in areas where a risk of explosion exists NOT connect this equipment to electrical outlets controlled by wall switches or automatic timers interference sources installing the equipment near heaters air conditioners ventilators and or refrigerators installing this equipment close to or on top of large metal objects e g metal wall studs Precautions Required During Installation install this equipment and or telephone wiring during a lightning storm touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface cables so that accidents can not occur Connected cables must NOT be subject to excessive mechanical strain only the power supply provided with this equipment Use of unauthorized power supplies may cause damage direct plug in versions use the transformer supplied with the device plug in versions only EQUIPMENT HAS NO MAINS ON OFF SWITCH THE PLUG OF THE DIRECT PLUG IN POWER SUPPLY IS TO SERVE AS THE DISCONNECTING DEVICE IF THE EQUIPMENT MUST BE QUICKLY DISCONNECTED IT IMPERATIVE THAT ACCESS TO THE MAINS PLUG AND ASSOCIATED MAINS SOCKET OUTLET IS NEVER THE PERMANENTLY CONNECTED POWER SUPPLY PTD1620 SCW IS USED THE INSTALLER IS RESPONSIBLE PROVIDING A READILY ACCESSABLE DISCONNECT DEVICE INCORPORATED EXTERNAL TO THE EQUIPMENT NOTE Alarm System shall be installed and used within an that provides the pollution degree max 2 and over category II NON HAZARDOUS LOCATIONS indoor The equipment is DIRECT PLUG IN external transformer is designed to be installed serviced and or repaired by persons only service person is defined as a person the appropriate technical training and experience to be aware of hazards to which that person may be in performing a task and of measures to minimize the to that person or other persons There are no parts by the end user within this equipment The wiring used for installation of the Alarm System and shall be insulated with PVC TFE PTFE FEP or Polyamide The equipment enclosure must be secured to the building before operation Internal wiring must be routed in a manner that prevents Excessive strain or loosening of wire on terminal connections Damage of conductor insulation Disposal of used batteries shall be made in accordance with waste recovery and recycling regulations Before servicing DISCONNECT the power and telephone DO NOT route any wiring over circuit boards It is the installer responsibility to ensure that a readily disconnect device is incorporated in the building permanently connected insta