DSC Install Manual WS4904P-WS8904P - Eng - Dut - Swe

File Preview
File Preview
Click below to download for free

File Data

Name dsc-install-manual-ws4904p-ws8904p-eng-dut-swe-0269138457.pdf
Type PDF
Size 1023.28 KB
Downloads

Text Preview

cid 129 Mount the detector flat on a wall or in a corner Do not angle it downwards or use mounting brackets with this detec Monteer de melder vlak tegen een muur of in een hoek Richt deze niet naar beneden of gebruik bij deze melder wanneer deze Do not aim the detector at reflective surfaces such as mirrors or windows as this may distort the coverage pattern or Richt de melder niet op een weerkaatsend oppervlak zoals spiegels of ramen dit kan het dekkingspatroon storen of het zonlicht 6ft 1.8m from the detector when it is used in conjunction with pets sunlight directly onto the detector Installation Instructions Installation Manual shall be used in conjunction with the Installation Manual of the DSC wireless receiver and control with which this device is intended to be used WS4904P WS8904P detector is designed to combine the convenience of a wireless detector with effective and reli detection of human motion as well as good protection against the nuisance alarms associated with pets weighing up 27.3 kg 60 lbs the Detector WS4904P WS8904P detector provides effective immunity to single or multiple pets whose total combined weight not exceed 60 lbs 27.3kg when installed and configured in the following manner a detector location that will provide the coverage required and will allow the detector to be mounted a minimum of ft 1.95m high and not higher than 10ft 3m 7 ft 2.3m recommended the following to avoid false alarms Do not aim the detector at a stairwell to which a pet has access Do not place furniture or objects higher than 3ft 0.9m which a pet can climb onto e g a cat on a couch closer Avoid locations that are subject to direct high air flow such as near an air duct outlet Do not locate the detector near sources of moisture such as steam or oil Do not limit the coverage by large obstructions in the detection area such as plants or cabinets For indoor use only non hazardous locations No detector should be mounted without first performing a module placement test to determine it is in range of the wireless receiver See the Placement Test instructions in the Instruction Sheet for receiver or in the Installation Manual for your system a location has been selected remove the plastic from the mounting holes and locate the backplate on the wall and screw locations It is suggested that wall anchors be used for all screw locations Secure the backplate to the wall then secure the enrolled detector to its backplate Use only backplates Using any other backplates will result in the tamper switch being a WS4904P WS8904P the back of the PIR housing there will be a six digit number the Sensitivity Setting WS4904P WS8904P features and settings on jumper JP1 which is used to configure the detector for weight of the pet s and the environment For an environment with a single pet whose weight does not exceed 30lbs the jumper should be set to setting In an environment with single or multiple pets whose combined is greater than 30lbs 13.6kg but not greater than 60 lbs 27.3kg the jumper must be set to the setting the detector is mounted 6 ft to 7 ft high 1.95 to 2.3 m or there is the possibility of the pet getting higher than 1.2 m the slow setting must be used To change the setting from Slow to Fast move the jumper over one pin as in the diagram Traffic Shutdown Mode prolong battery life the motion detector uses a feature called High Traffic Shutdown When motion is detected the will transmit to the receiver and will then shut down for three minutes If motion is detected again during the shut time the unit will not transmit the event to the receiver The detector will thus remain in the shutdown mode until minutes after the first motion detected was transmitted The detector will transmit detected motion every three min High Traffic Shutdown Mode affects testing the motion detector in two ways When performing the module placement test the unit must be tampered by removing it from the backplate and it The placement test cannot be performed by creating motion in front of the device When performing a system test the unit must be left idle for three minutes before testing can be performed Once minutes has passed create motion in front of the detector to see if the device is both detecting motion and to the receiver Detector Transmission Delay motion detector transmission is always delayed by six seconds This is necessary to prevent false alarms caused by a sensor transmitting before a delay zone has a chance to report This six second delay cannot be altered or dis Test Mode motion detector has a walk test mode which will activate an LED for testing purposes During normal operation the will not turn on To put the detector in walk test mode create a tamper by removing the detector from its backplate then replacing it Each time the detector senses motion it will flash the red LED Six seconds after motion is detected detector will send a signal to the receiver The detector will be in walk test mode until it has sent 10 transmissions verify the pet immunity of the detector place the animal s within the coverage area and then move out of the zone the pet to move around as it normally would and ensure that it moves across the detection pattern of the detec Verify that no alarm is initiated To test for catch performance of humans create motion in the entire area where cover is desired by walking perpendicular to the lens pattern Should the coverage be incomplete readjust or relocate the The Walk Test Mode will override the High Traffic Shutdown Mode If the installer is activating the walk test mode or replacing a battery that he must create 10 alarm before leaving the area because the indicator is still working and will not stop working 10 alarm transmissions have been sent Installation Fig 3 This system is designed to work with the following consumer grade batteries Energizer Lithium EL123AP Panasonic CR123A or Duracell Lithium Ultra 123 Do not install any other type The reliability of the security system on its batteries and name or generic brand batteries may not provide the best quality and dependabi Use of another type of battery may present a risk of fire or explosion Use a fresh battery Most batteries have a before date printed on their packaging or on the batteries themsel Buy batteries that have a before date of two years or more from your purchase date the motion detector from its mounting plate by holding the sensor by its sides and pushing up Remove the bat cover see Figure 3 Remove the old battery and install new battery Place the battery cover back on Secure the battery cover with the small screw provided the sensor on its mounting plate making sure it snaps into place After the battery is installed the detector will 60 seconds to warm up During this time the LED will flash slowly The polarity of the battery must be observed Figure3 Improper handling of lithium batteries result in heat generation explosion or fire which may lead to personal injuries DANGER OF EXPLOSION IF BATTERIES ARE INSTALLED INCORRECTLY REPLACE ONLY WITH THE OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER away from small children If batteries are swallowed promptly see a doctor Do not try to recharge batteries Disposal of used batteries must be made in accordance with the waste recovery and regulations in your area The battery may explode if mistreated Do not dispose of in fire recharge or disassemble Operating Temperature 10 to 55 14 to 131 UL 0 to 49 32 to 120.2 Operating Humidity 5 to 93 RH non cond Operating Frequency 433.92MHz WS4904P 868.35MHz WS8904P Battery Life 9 years typical usage in room temperature Battery Nominal Voltage is 3V Low Battery Trouble indication is provided at 2.2V Compatible with RF5132 433 868 RF4164 433 868 RFK55XX 433 868 RF5108 433 868 SCW9045 47 433 SCW9055 57 433 PC9155 433 868 WS4920 WS8920 Installatiehandleiding instructies dienen te worden gebruikt in combinatie met de installatiehandleiding van de DSC draadloze ontvanger en cen waarmee deze apparatuur gebruikt gaat worden WS4904P WS8904P melder is ontworpen voor combinatie van het gemak van een draadloze melder met effectieve en bet detectie van menselijke bewegingen en als goede bescherming tegen hinderlijke alarmen die met huisdieren tot een van 27,3 kg 60 lbs gepaard gaan van de melder WS4904P WS8904P melder biedt effectieve immuniteit tegen een of meerdere huisdieren met een totaal gecombineerd gewicht 60 lbs 27,3kg wanneer deze op de volgende manier wordt ge en geconfigureerd

Related Files